Emitted doses of salbutamol pressurized metered-dose inhaler from five different plastic spacer devices

被引:9
作者
Dubus, JC [1 ]
Dolovich, M
机构
[1] CHU Timone Enfants, Serv Med Infantile, F-13385 Marseille 5, France
[2] McMaster Univ, Hlth Sci Ctr, Dept Med, Hamilton, ON L8N 3Z5, Canada
关键词
asthma; children; inhaled therapy; in vitro study; salbutamol; spacer devices;
D O I
10.1111/j.1472-8206.2000.tb00019.x
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
In a recent clinical study we have demonstrated that the bronchodilator effect of 200 mu g salbutamol (Ventoline(R)) was spacer device-dependent in 100 tested asthmatic children, with the Babyhaler(R) providing greater efficacy for improving peak expiratory flow rate compared to Aeroscopic(R), Nebuhaler(R), Aerochamber(R) and Volumatic(R). The aim of this present study was to correlate our clinical results to in vitro determinations of the emitted dose (ED) of Ventoline(R) administered via these five different plastic spacer devices. ED was determined from the mean of single doses collected in unit dose sampling tubes using a constant suction flow of 28.3 L/min. Three pressurized metered-dose inhalers and three sets of spacer devices were used to obtain a total of 30 measurements per group. Inter-group results were compared by RM-ANOVA or Student-Newman-Keuls method when indicated. Babyhaler(R) delivered significantly (P < 0.05) more salbutamol than Nebuhaler(R), Aerochamber(R) and Aeroscopic(R) (mean +/- standard deviation: 63.6 +/- 2.9 mu g/100 mu g actuation for Babyhaler(R) vs. 59.4 +/- 8.6 for Nebuhaler(R), 50.8 +/- 5.0 for Aerochamber(R) and 47.5 +/- 2.5 for Aeroscopic(R)). The ED from Volumatic(R) (61.5 +/- 7.9 mu g/100 mu g actuation) was similar to that from the Babyhaler(R). The variability in the ED was greatest with the large volume spacers. Despite a greater ED from the Babyhaler(R), in vitro results do not fully explain the in vivo results. However, the previously described clinical improvement seen with the Babyhaler(R) may be due to the quantitatively different aerosol production in a more 'useful' size range, as well as the different breathing patterns of the children tested. The results of this present study question the relevance of mouthpiece filter collection studies using a constant sampling in predicting clinical or physiological outcomes. (C) 2000 Editions scientifiques et medicales Elsevier SAS.
引用
收藏
页码:219 / 224
页数:6
相关论文
共 36 条
  • [1] CHOOSING THE METERED-DOSE INHALER SPACER OR HOLDING CHAMBER THAT MATCHES THE PATIENTS NEED - EVIDENCE THAT THE SPECIFIC DRUG BEING DELIVERED IS AN IMPORTANT CONSIDERATION
    AHRENS, R
    LUX, C
    BAHL, T
    HAN, SH
    [J]. JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1995, 96 (02) : 288 - 294
  • [2] Inhalational drug delivery from seven different spacer devices
    Barry, PW
    OCallaghan, C
    [J]. THORAX, 1996, 51 (08) : 835 - 840
  • [3] OPTIMUM USE OF A SPACER DEVICE
    BARRY, PW
    ROBERTSON, CF
    OCALLAGHAN, C
    [J]. ARCHIVES OF DISEASE IN CHILDHOOD, 1993, 69 (06) : 693 - 694
  • [4] In vitro comparison of the amount of salbutamol available for inhalation from different formulations used with different spacer devices
    Barry, PW
    OCallaghan, C
    [J]. EUROPEAN RESPIRATORY JOURNAL, 1997, 10 (06) : 1345 - 1348
  • [5] BARRY PW, 1997, AM J RESP CRIT CARE, V155, pA671
  • [6] A NONELECTROSTATIC SPACER FOR AEROSOL DELIVERY
    BISGAARD, H
    ANHOJ, J
    KLUG, B
    BERG, E
    [J]. ARCHIVES OF DISEASE IN CHILDHOOD, 1995, 73 (03) : 226 - 230
  • [7] BYRON PR, 1994, PHARMACOPEIAL FORUM, V20, P7477
  • [8] Effect of multiple actuations, delayed inhalation and antistatic treatment on the lung bioavailability of salbutamol via a spacer device
    Clark, DJ
    Lipworth, BJ
    [J]. THORAX, 1996, 51 (10) : 981 - 984
  • [9] DELIVERY OF SALBUTAMOL BY METERED-DOSE INHALER AND VALVED SPACER TO WHEEZY INFANTS - EFFECT ON BRONCHIAL RESPONSIVENESS
    CLARKE, JR
    ASTON, H
    SILVERMAN, M
    [J]. ARCHIVES OF DISEASE IN CHILDHOOD, 1993, 69 (01) : 125 - 129
  • [10] POTENTIAL LIMITATIONS OF A CONICAL SPACER DEVICE IN SEVERE ASTHMA
    COX, ID
    WALLIS, PJW
    APPS, MCP
    [J]. BRITISH MEDICAL JOURNAL, 1984, 288 (6423) : 1044 - 1044