Electrochemical selenium hydride generation with in situ trapping in graphite tube atomizers

被引:29
作者
Síma, J
Rychlovsky, P
机构
[1] Charles Univ Prague, Dept Analyt Chem, Prague 2, Czech Republic
[2] Acad Sci Czech Republ, Inst Analyt Chem, Prague 4, Czech Republic
关键词
electrochemical hydride generation; electrothermal atomic absorption spectrometry; in situ trapping; selenium hydride;
D O I
10.1016/S0584-8547(03)00035-1
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A manifold coupling continuous electrolytic hydride generation of volatile hydrides with atomization in graphite tube atomizers after in situ collection was used for Se(IV) determination. Laboratory-made thin-layer flow-through cells with lead wire (cell I) and granular lead (cell II) as the cathode material were used as the electrolytic generators of volatile selenium hydride. The automatic sampling equipment of the graphite atomizer, with an untreated fused silica capillary, was used both for the introduction of volatile hydride into the atomizer and for pretreatment of the graphite furnace surface with a palladium modifier. The influence of the experimental parameters on the analytical signal was studied and optimum conditions for selenium determination were found. The optimum experimental parameters for hydride generation were: catholyte (1 mol l(-1) HCl)/anolyte (2 mol l(-1) H2SO4) flow rate of 2.0 ml min(-1); applied generation current of 1.2 A (cell I) and 0.8 A (cell II); and carrier gas flow rate of 40 (cell I) and 70 ml min(-1) (cell II). The hydride generated was collected in the graphite tube (pre-treated with 5 mug of Pd reduced at 800 degreesC) at a temperature of 400 degreesC for 30 s. The overall efficiency of H2Se electrochemical generation, transport and collection was 71 +/- 7% for cell I and 80 +/- 5% for cell II. The results for electrochemical generation of H2Se (cell II) (absolute limit of detection 50 pg, 3sigma criterion) were compared with the original generation of H2Se using NaBH4 as a reduction agent (absolute limit of detection 30 pg) and with conventional liquid sampling. The repeatability at the 1.0 ng ml(-1) level was better than 2.4% (relative standard deviation) for electrochemical hydride generation and better than 2.8% for chemical hydride generation. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:919 / 930
页数:12
相关论文
共 24 条
[1]   Interferences in electrochemical hydride generation of hydrogen selenide [J].
Bolea, E ;
Laborda, F ;
Belarra, MA ;
Castillo, YR .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2001, 56 (12) :2347-2360
[2]   NEW CONCEPT FOR HYDRIDE GENERATION TECHNIQUE - ELECTROCHEMICAL HYDRIDE GENERATION [J].
BROCKMANN, A ;
NONN, C ;
GOLLOCH, A .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (03) :397-401
[3]  
DEDINA J, 1998, P SEMIN AT SPECTROCH, P53
[4]  
DEDINA J, 1995, HYDRIDE GENERATION A
[5]   Electrolytic hydride generation electrothermal atomic absorption spectrometry - in situ trapping of As on different pre-conditioned end-heated graphite tubes [J].
Denkhaus, E ;
Golloch, A ;
Kampen, TU ;
Nierfeld, M ;
Telgheder, U .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 361 (6-7) :733-737
[6]   Electrolytic hydride generation (EC-HG) - a sample introduction system with some special features [J].
Denkhaus, E ;
Golloch, A ;
Guo, XM ;
Huang, B .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (08) :870-878
[7]   Electrolytic hydride generation atomic absorption spectrometry for the determination of antimony, arsenic, selenium, and tin - mechanistic aspects and figures of merit [J].
Denkhaus, E ;
Beck, F ;
Bueschler, P ;
Gerhard, R ;
Golloch, A .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 370 (06) :735-743
[8]   Interference of copper and nickel on electrochemical hydride generation [J].
Ding, WW ;
Sturgeon, RE .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (06) :421-425
[9]   Evaluation of electrochemical hydride generation for the determination of total antimony in natural waters by electrothermal atomic absorption spectrometry with in situ concentration [J].
Ding, WW ;
Sturgeon, RE .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (03) :225-230
[10]   Evaluation of electrochemical hydride generation for the determination of arsenic and selenium in sea water by graphite furnace atomic absorption with in situ concentration [J].
Ding, WW ;
Sturgeon, RE .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1996, 51 (11) :1325-1334