Technical Innovation: Multidimensional Computerized Software Enabled Subtraction Computed Tomographic Angiography

被引:2
作者
Bhatia, Mona [1 ]
Rosset, Antoine [1 ]
Platon, Alexandra [1 ]
Didier, Dominique [1 ]
Becker, Christoph D. [1 ]
Poletti, Pierre-Alexandre [1 ]
机构
[1] Univ Geneva, Univ Hosp Geneva, Dept Radiol, CH-1211 Geneva, Switzerland
关键词
CT angiography; subtraction; computerized subtraction software; CEREBRAL ANEURYSMS; CT ANGIOGRAPHY; INTRACRANIAL ANEURYSMS; MULTISLICE CT; HELICAL CT; RECONSTRUCTION; DIAGNOSIS; STENOSIS; ARTERY;
D O I
10.1097/RCT.0b013e3181d0c5d0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Computed tomographic angiography (CTA) is a frequent noninvasive alternative to digital subtraction angiography. We previously reported the development of a new subtraction software to overcome limitations of adjacent bone and calcification in CT angiographic subtraction. Our aim was to further develop and improve this fast and automated computerized software, universally available for free use and compatible with most CT scanners, thus enabling better delineation of vascular structures, artifact reduction, and shorter reading times with potential clinical benefits. This computer-based free software will be available as an open source in the next release of OsiriX at the Web site http://www.osirix-viewer.com.
引用
收藏
页码:465 / 468
页数:4
相关论文
共 17 条
[1]   Computed tomographic angiography versus digital subtraction angiography for the diagnosis and early treatment of ruptured intracranial aneurysms [J].
Anderson, GB ;
Steinke, DE ;
Petruk, KC ;
Ashforth, R ;
Findlay, JM .
NEUROSURGERY, 1999, 45 (06) :1315-1320
[2]   Cerebral CT venography [J].
Casey, SO ;
Alberico, RA ;
Patel, M ;
Jimenez, JM ;
Ozsvath, RR ;
Maguire, WM ;
Taylor, ML .
RADIOLOGY, 1996, 198 (01) :163-170
[3]   Comparison of computed tomographic angiography with digital subtraction angiography in the diagnosis of cerebral aneurysms: A meta-analysis [J].
Chappell, ET ;
Moure, FC ;
Good, MC .
NEUROSURGERY, 2003, 52 (03) :624-630
[4]   Detection of intracranial aneurysms with multislice CT: comparison with conventional angiography [J].
Dammert, S ;
Krings, T ;
Moller-Hartmann, W ;
Ueffing, E ;
Hans, FJ ;
Willmes, K ;
Mull, M ;
Thron, A .
NEURORADIOLOGY, 2004, 46 (06) :427-434
[5]   Microsurgical management of cerebral aneurysms based in CT angiography with three-dimensional reconstruction (3D-CTA) and without preoperative cerebral angiography [J].
González-Darder, JM ;
Pesudo-Martínez, JV ;
Feliu-Tatay, RA .
ACTA NEUROCHIRURGICA, 2001, 143 (07) :673-679
[6]   Maximum stenosis of extracranial internal carotid artery: Effect of luminal morphology on stenosis measurement by using CT angiography and conventional DSA [J].
Hirai, T ;
Korogi, Y ;
Ono, K ;
Murata, Y ;
Takahashi, M ;
Suginohara, K ;
Uemura, S .
RADIOLOGY, 2001, 221 (03) :802-809
[7]   Results of a prospective protocol of computed tomographic angiography in place of catheter angiography as the only diagnostic and pretreatment planning study for cerebral aneurysms by a combined neurovascular team [J].
Hoh, BL ;
Cheung, AC ;
Rabinov, JD ;
Pryor, JC ;
Carter, BS ;
Ogilvy, CS .
NEUROSURGERY, 2004, 54 (06) :1329-1340
[8]   Intracranial aneurysms: evaluation using CTA and MRA. Correlation with DSA and intraoperative findings [J].
Kouskouras, C ;
Charitanti, A ;
Giavroglou, C ;
Foroglou, N ;
Selviaridis, P ;
Kontopoulos, V ;
Dimitriadis, AS .
NEURORADIOLOGY, 2004, 46 (10) :842-850
[9]   Computed tomography angiography versus digital subtraction angiography in vascular mapping for planning of microsurgical reconstruction of the mandible [J].
Lell, M ;
Tomandl, BF ;
Anders, K ;
Baum, U ;
Nkenke, E .
EUROPEAN RADIOLOGY, 2005, 15 (08) :1514-1520
[10]   Value of automatic bone subtraction in cranial CT angiography: comparison of bone-subtracted vs. standard CT angiography in 100 patients [J].
Morhard, Dominik ;
Fink, Christian ;
Becker, Christoph ;
Reiser, Maximilian F. ;
Nikolaou, Konstantin .
EUROPEAN RADIOLOGY, 2008, 18 (05) :974-982