Comparison of the periimplant bone stress distribution on three fixed partial supported prosthesis designs under different loading. A 3D finite element analysis

被引:0
|
作者
deLlanos-Lanchares, Hector [1 ]
Alvarez-Arenal, Angel [1 ]
Bobes Bascaran, Javier [2 ]
Gonzalez-Gutierrez, Carlos [3 ]
Suarez Sanchez, Ana [4 ]
Blanco Alvarez, Francisco [5 ]
机构
[1] Univ Oviedo, Prosthodont & Occlus Dept, Oviedo, Spain
[2] Avsan Holdings Ltd, Luton, Beds, England
[3] Univ Oviedo, Dept Mines Prospecting & Exploitat, Oviedo, Spain
[4] Univ Oviedo, Dept Business Adm, Oviedo, Spain
[5] Univ Oviedo, Dept Mat Sci & Met Engn, Oviedo, Spain
关键词
Three-unit bridge; occlusal loading; bone density; tilted implant; cantilever prosthesis; PROSTATE-CANCER; PARTIAL DENTURES; IMPLANTS; LENGTH;
D O I
10.1080/0952813X.2019.1572656
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Despite high success and survival rates of implant-supported prosthesis therapy, biomechanical complications such as periimplant bone resorption continue to exist due to occlusal overloading. The purpose of this article is to analyse and compare the influence of bone density, direction and distribution of the occlusal load and the design of three-unit implant-supported prostheses. Three-dimensional finite element analysis study was developed to evaluate the influence on the periimplant bone stress distribution of three different designs of a 3-unit bridge supported by two implants (intermediate pontic, tilted implant, cantilever pontic), two different bone qualities (D3 and D4), and different loading directions (axial and non-axial) and distributions (uniform and non-uniform). Bridge configuration with intermediate pontic and parallel implants presents the lowest periimplant stress, whereas the highest stress was found on the tilted implant bridge. Bone D3 is biomechanically more favourable than D4. Non-axial and uniform loading conditions produce more periimplant stress. Distal cantilever and 45? convergent distal tilted implant are the second and third treatment options on a posterior three-unit rehabilitation. Lightening occlusal contacts on the pontic and avoiding non-axial loading, reduce periimplant bone stress. Bone D4 increases periimplant bone strain.
引用
收藏
页码:875 / 888
页数:14
相关论文
共 31 条
  • [21] An investigation of effect of rigid and nonrigid connector designs on implant as pier abutment in implant tooth-supported fixed dental prosthesis with three-dimensional finite element analysis: An In vitro study
    Kumar, S. Manoj
    Jei, J. Brintha
    Krishnan, Murugesan
    ADVANCES IN HUMAN BIOLOGY, 2021, 11 (04) : 45 - 50
  • [22] Influence of location of osseointegrated implant on stress distribution in implant supported longitudinal removable partial dentures: 3-dimensional finite element analysis
    Liu, Yang
    Zhang, Yi-Nan
    Sasaki, Keiichi
    Chen, Xiao-Dong
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2019, 12 (08): : 10399 - 10410
  • [23] Finite element analysis of low-profile reconstruction plates for atrophic mandibles: a comparison of novel 3D grid and conventional plate designs
    Guerra, Raphael Capelli
    Borim Pulino, Bianca de Fatima
    Salomao Junior, Vitor Floriano
    Pereira, Rodrigo dos Santos
    Thieringer, Florian M.
    Sacco, Roberto
    Sader, Robert
    Vieira, Eduardo Hochuli
    ORAL AND MAXILLOFACIAL SURGERY-HEIDELBERG, 2024, 28 (02): : 595 - 603
  • [24] Stress analysis in bone tissue around single implants with different diameters and veneering materials: A 3-D finite element study
    Santiago Junior, Joel Ferreira
    Pellizzer, Eduardo Piza
    Verri, Fellippo Ramos
    Perri de Carvalho, Paulo Sergio
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2013, 33 (08): : 4700 - 4714
  • [25] Comparison of the rehabilitation of posterior atrophic edentulous mandible with different interforaminal implant placement concepts: a 3D finite element analysis
    Akca, B. S.
    Kucukkurt, S.
    JOURNAL OF OSSEOINTEGRATION, 2023, 15 (03) : 155 - 164
  • [26] Biomechanical Analysis of Different Framework Design, Framework Material and Bone Density in the Edentulous Mandible With Fixed Implant-Supported Prostheses: A Three-Dimensional Finite Element Study
    Yu, Wenqian
    Chen, Siyi
    Ma, Li
    Ma, Xiaoni
    Xu, Xin
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 (04): : 309 - 317
  • [27] Effect of different designs of minimally invasive cantilever resin-bonded fixed dental prostheses replacing mandibular premolar: Long-term fracture load and 3D finite element analysis
    Kasem, Ammar T.
    Elsherbiny, Abdallah Ahmed
    Abo-Madina, Manal
    Tribst, Joao Paulo M.
    Al-Zordk, Walid
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 (03): : E41 - E51
  • [28] Influence of Treatment Plans on Stress and Deformation Distribution in Mandibular Implant-Supported Overdenture and Mandibular Bone under Traumatic Load: A 3D FEA
    Manafi Khajeh Pasha, Anahita
    Mahmoudi Sheykhsarmast, Reza
    Manafi Khajeh Pasha, Siavash
    Khashabi, Ehsan
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2021, 41 (04) : 543 - 557
  • [29] Influence of Resin Cement Thickness and Elastic Modulus on the Stress Distribution of Zirconium Dioxide Inlay-Bridge: 3D Finite Element Analysis
    Assaf, Joseph
    Hardan, Louis
    Kassis, Cynthia
    Bourgi, Rim
    Devoto, Walter
    Amm, Elie
    Moussa, Carol
    Sawicki, Jacek
    Lukomska-Szymanska, Monika
    POLYMERS, 2021, 13 (22)
  • [30] Biomechanical Effects of Different Load Cases with an Implant-Supported Full Bridge on Four Implants in an Edentulous Mandible: A Three-Dimensional Finite Element Analysis (3D-FEA)
    Szabo, arpad Laszlo
    Matusovits, Danica
    Slyteen, Haydar
    Lakatos, eva Ilona
    Barath, Zoltan
    Schmidlin, Patrick R.
    DENTISTRY JOURNAL, 2023, 11 (11)