Comparison of the periimplant bone stress distribution on three fixed partial supported prosthesis designs under different loading. A 3D finite element analysis

被引:0
|
作者
deLlanos-Lanchares, Hector [1 ]
Alvarez-Arenal, Angel [1 ]
Bobes Bascaran, Javier [2 ]
Gonzalez-Gutierrez, Carlos [3 ]
Suarez Sanchez, Ana [4 ]
Blanco Alvarez, Francisco [5 ]
机构
[1] Univ Oviedo, Prosthodont & Occlus Dept, Oviedo, Spain
[2] Avsan Holdings Ltd, Luton, Beds, England
[3] Univ Oviedo, Dept Mines Prospecting & Exploitat, Oviedo, Spain
[4] Univ Oviedo, Dept Business Adm, Oviedo, Spain
[5] Univ Oviedo, Dept Mat Sci & Met Engn, Oviedo, Spain
关键词
Three-unit bridge; occlusal loading; bone density; tilted implant; cantilever prosthesis; PROSTATE-CANCER; PARTIAL DENTURES; IMPLANTS; LENGTH;
D O I
10.1080/0952813X.2019.1572656
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Despite high success and survival rates of implant-supported prosthesis therapy, biomechanical complications such as periimplant bone resorption continue to exist due to occlusal overloading. The purpose of this article is to analyse and compare the influence of bone density, direction and distribution of the occlusal load and the design of three-unit implant-supported prostheses. Three-dimensional finite element analysis study was developed to evaluate the influence on the periimplant bone stress distribution of three different designs of a 3-unit bridge supported by two implants (intermediate pontic, tilted implant, cantilever pontic), two different bone qualities (D3 and D4), and different loading directions (axial and non-axial) and distributions (uniform and non-uniform). Bridge configuration with intermediate pontic and parallel implants presents the lowest periimplant stress, whereas the highest stress was found on the tilted implant bridge. Bone D3 is biomechanically more favourable than D4. Non-axial and uniform loading conditions produce more periimplant stress. Distal cantilever and 45? convergent distal tilted implant are the second and third treatment options on a posterior three-unit rehabilitation. Lightening occlusal contacts on the pontic and avoiding non-axial loading, reduce periimplant bone stress. Bone D4 increases periimplant bone strain.
引用
收藏
页码:875 / 888
页数:14
相关论文
共 31 条
  • [1] Comparison of the Periimplant Bone Stress Distribution on Three Fixed Partial Supported Prosthesis Designs Under Different Loading. A 3D Finite Element Analysis
    DeLlanos-Lanchares, Hector
    Alvarez-Arenal, Angel
    Bascaran, Javier Bobes
    Gonzalez-Gutierrez, Carlos
    Suarez Sanchez, Ana
    Blanco Alvarez, Francisco
    INTERNATIONAL JOINT CONFERENCE SOCO'17- CISIS'17-ICEUTE'17 PROCEEDINGS, 2018, 649 : 410 - 418
  • [2] Stress Distribution in Bone and Implants in Mandibular 6-Implant-Supported Cantilevered Fixed Prosthesis: A 3D Finite Element Study
    Padhye, Omkar Vinayak
    Herekar, Manisha
    Patil, Viraj
    Mulani, Shahnawaz
    Sethi, Megha
    Fernandes, Aquaviva
    IMPLANT DENTISTRY, 2015, 24 (06) : 680 - 685
  • [3] Mechanical response of different frameworks for maxillary all-on-four implant-supported fixed dental prosthesis: 3D finite element analysis
    Guclu, Zekiye Begum
    Gurbuz, Ayhan
    Gokay, Gonca Deste
    Durkan, Rukiye
    Oyar, Perihan
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2022, 67 (05): : 419 - 428
  • [4] Three-dimensional finite element analysis of occlusal splint and implant connection on stress distribution in implant-supported fixed dental prosthesis and peri-implantal bone
    Marsico, Vivian dos Santos
    Lehmann, Roberto Brunow
    de Assis Claro, Cristiane Aparecida
    Amaral, Marina
    Vitti, Rafael Pino
    Claro Neves, Ana Christina
    da Silva Concilio, Lais Regiane
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2017, 80 : 141 - 148
  • [5] Stress Distribution in Splinted and Unsplinted Implant-Supported Maxillary Overdentures: A 3D Finite Element Analysis
    Geramy, Allahyar
    Habibzadeh, Sareh
    IMPLANT DENTISTRY, 2018, 27 (01) : 56 - 62
  • [6] Stress Evaluation of Implant-Abutment Connections Under Different Loading Conditions: A 3D Finite Element Study
    Ferreira Koyama Takahashi, Jessica Mie
    Dayrell, Andreza Costa
    Xediek Consani, Rafael Leonardo
    de Arruda Nobilo, Mauro Antonio
    Pessanha Henriques, Guilherme Elias
    Mesquita, Marcelo Ferraz
    Journal of Oral Implantology, 2015, 41 (02) : 133 - 137
  • [7] Influence of prosthesis type and material on the stress distribution in bone around implants: A 3-dimensional finite element analysis
    Meric, Gokce
    Erkmen, Erkan
    Kurt, Ahmet
    Tunc, Yahya
    Eser, Atilim
    JOURNAL OF DENTAL SCIENCES, 2011, 6 (01) : 25 - 32
  • [8] Three-Dimensional Finite Element Analysis of Different Connector Designs for All-Ceramic Implant-Supported Fixed Dental Prostheses
    Alberto, Laura H. J.
    Kalluri, Lohitha
    Esquivel-Upshaw, Josephine F.
    Duan, Yuanyuan
    CERAMICS-SWITZERLAND, 2022, 5 (01): : 34 - 43
  • [9] Short communication: Influence of retainer configuration and loading direction on the stress distribution of lithium disilicate resin-bonded fixed dental prostheses: 3D finite element analysis
    Dal Piva, Amanda M. O.
    Tribst, Joao P. M.
    Saavedra, Guilherme S. F. A.
    Souza, Rodrigo O. A.
    de Melo, Renata M.
    Borges, Alexandre L. S.
    Ozcan, Mutlu
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2019, 100
  • [10] Stress evaluation of different implant lengths on atrophic edentulous mandibles with fixed full-arch implant-supported prosthesis: a finite element analysis
    Benevides, Fernanda
    Cimoes, Renata
    Vajgel, Andre
    Wilmersdorf, Ramiro Brito
    Farias Vajgel, Bruna de Carvalho
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2021, 24 (04) : 358 - 374