Ethnic differences in optic nerve head and retinal nerve fibre layer thickness parameters in children

被引:52
|
作者
Samarawickrama, Chameen [1 ,2 ]
Wang, Jie Jin [1 ,2 ,4 ]
Huynh, Son C. [1 ,2 ]
Pai, Amy [1 ,2 ]
Burlutsky, George [1 ,2 ]
Rose, Kathryn A. [3 ]
Mitchell, Paul [1 ,2 ]
机构
[1] Univ Sydney, Dept Ophthalmol, Ctr Vis Res, Sydney, NSW 2006, Australia
[2] Univ Sydney, Westmead Millennium Inst, Sydney, NSW 2006, Australia
[3] Univ Sydney, Fac Hlth Sci, Sch Appl Vis Sci, Sydney, NSW 2006, Australia
[4] Univ Melbourne, Ctr Eye Res Australia, Melbourne, Vic, Australia
基金
英国医学研究理事会;
关键词
OPEN-ANGLE GLAUCOMA; SINGAPORE MALAY EYE; BLUE MOUNTAINS EYE; COHERENCE-TOMOGRAPHY; VISUAL IMPAIRMENT; MACULAR THICKNESS; POPULATION; PREVALENCE; DISC; AGE;
D O I
10.1136/bjo.2009.158279
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aim To examine ethnic differences in optic nerve head and retinal nerve fibre layer (RNFL) parameters between European Caucasian and East Asian children aged 6-12 years. Methods Of 4118 children examined in the Sydney Childhood Eye Study (incorporating the Sydney Myopia Study) from 34 randomly selected primary and 21 secondary schools during 2003-5, 3382 (82.1%) had optical coherence tomography (OCT; Zeiss Stratus) data suitable for analysis. 'Fast' optic disc and RNFL scans were used. Ethnicity was defined only when both parents were of the same ethnicity. Results East Asian children tended to have a lower birth weight, were shorter with a smaller body mass index and were less hyperopic than European Caucasian children of the same age. After adjusting for age, gender, axial length, birth weight and optic-disc area, East Asian children had similar mean vertical disc diameters to European Caucasians (p=0.38, p=0.64 for 6-12 years, respectively) but 30-43% larger mean vertical cup diameters (p<0.0001 for both), resulting in larger mean cup/disc ratios (p<0.0001 for both). Compared with European Caucasians (101.95 mm and 104.57 mm, respectively), East Asian children had thicker mean average RNFL (105.45 mm and 107.92 mm, respectively; p=0.0006 and 0.0001) and thicker non-nasal RNFL quadrants in both ages. Conclusions Compared with European Caucasian children, East Asian children generally had thicker RNFL and larger mean cup/disc ratios. Given the relatively lower prevalence of open angle glaucoma in Asians, these anatomical variations could contribute to better understanding of apparent racial differences in glaucoma susceptibility.
引用
收藏
页码:871 / 876
页数:6
相关论文
共 50 条
  • [41] Prospective Study on Retinal Nerve Fibre Layer Thickness Changes in Isolated Unilateral Retrobulbar Optic Neuritis
    Yau, Gordon S. K.
    Lee, Jacky W. Y.
    Lau, Patrick P. K.
    Tam, Victor T. Y.
    Wong, Winnie W. Y.
    Yuen, Can Y. F.
    SCIENTIFIC WORLD JOURNAL, 2013,
  • [42] Normative data for macular and retinal nerve fibre layer thickness in healthy German children and adolescents using optical coherence tomography
    Soehnel, Tanja
    Meigen, Christof
    Hiemisch, Andreas
    Wahl, Siegfried
    Ziemssen, Focke
    Truckenbrod, Carolin
    Huebner, Katharina
    Kiess, Wieland
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2023, 43 (04) : 922 - 934
  • [43] Peripapillary retinal nerve fibre layer thickness and its association with refractive error in Chinese children: the Anyang Childhood Eye Study
    Kang, Meng-Tian
    Li, Shi-Ming
    Li, He
    Li, Lei
    Li, Si-Yuan
    Zhu, Bi-Dan
    Guo, Yi-Qin
    Meng, Bo
    Sun, Yun-Yun
    Ran, Anran
    Wang, Yi-Peng
    Liu, Luo-Ru
    Zhan, Si-Yan
    Thomas, Ravi
    Wang, Ningli
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2016, 44 (08) : 701 - 709
  • [44] Optic Nerve Head Deformation in Glaucoma The Temporal Relationship between Optic Nerve Head Surface Depression and Retinal Nerve Fiber Layer Thinning
    Xu, Guihua
    Weinreb, Robert N.
    Leung, Christopher K. S.
    OPHTHALMOLOGY, 2014, 121 (12) : 2362 - 2370
  • [45] Relationship Between Position of Peak Retinal Nerve Fiber Layer Thickness and Retinal Arteries on Sectoral Retinal Nerve Fiber Layer Thickness
    Yamashita, Takehiro
    Asaoka, Ryo
    Tanaka, Minoru
    Kii, Yuya
    Yamashita, Toshifumi
    Nakao, Kumiko
    Sakamoto, Taiji
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (08) : 5481 - 5488
  • [46] Assessing Surface Shapes of the Optic Nerve Head and Peripapillary Retinal Nerve Fiber Layer in Glaucoma with Artificial Intelligence
    Saini, Chhavi
    Shen, Lucy Q.
    Pasquale, Louis R.
    Boland, Michael, V
    Friedman, David S.
    Zebardast, Nazlee
    Fazli, Mojtaba
    Li, Yangjiani
    Eslami, Mohammad
    Elze, Tobias
    Wang, Mengyu
    OPHTHALMOLOGY SCIENCE, 2022, 2 (03):
  • [47] Longitudinal Change of Circumpapillary Retinal Nerve Fiber Layer Thickness in Children With Optic Pathway Gliomas
    Avery, Robert A.
    Cnaan, Avital
    Schuman, Joel S.
    Trimboli-Heidler, Carmelina
    Chen, Chieh-Li
    Packer, Roger J.
    Ishikawa, Hiroshi
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2015, 160 (05) : 944 - 952
  • [48] Time-Course Changes in Optic Nerve Head Blood Flow and Retinal Nerve Fiber Layer Thickness in Eyes with Open-angle Glaucoma
    Kiyota, Naoki
    Shiga, Yukihiro
    Omodaka, Kazuko
    Pak, Kyongsun
    Nakazawa, Toru
    OPHTHALMOLOGY, 2021, 128 (05) : 663 - 671
  • [49] Peripapillary Retinal Nerve Fiber Layer and Optic Nerve Head Characteristics in Eyes With Situs Inversus of the Optic Disc
    Kang, Sunah
    Jin, Sunyoung
    Roh, Kyu Hwa
    Hwang, Young Hoon
    JOURNAL OF GLAUCOMA, 2015, 24 (04) : 306 - 310
  • [50] Sex-Specific Differences in Circumpapillary Retinal Nerve Fiber Layer Thickness
    Li, Dian
    Rauscher, Franziska G.
    Choi, Eun Young
    Wang, Mengyu
    Baniasadi, Neda
    Wirkner, Kerstin
    Kirsten, Toralf
    Thiery, Joachim
    Engel, Christoph
    Loeffler, Markus
    Elze, Tobias
    OPHTHALMOLOGY, 2020, 127 (03) : 357 - 368