Determination of organochlorine compounds in fish liver by ultrasound-assisted dispersive liquid-liquid microextraction based on solidification of organic droplet coupled with gas chromatography-electron capture detection

被引:25
作者
Asati, Ankita [1 ,2 ]
Satyanarayana, G. N. V. [2 ,3 ]
Srivastava, V. Tanmya [2 ]
Patel, Devendra K. [1 ,2 ]
机构
[1] Acad Sci & Innovat Res AcSIR, CSIR IITR Campus, Lucknow, Uttar Pradesh, India
[2] CSIR Indian Inst Toxicol Res, Analyt Chem Lab, Regulatory Toxicol Grp, Vishvigyan Bhawan 31,Mahatma Gandhi Marg, Lucknow 226001, Uttar Pradesh, India
[3] Babu Banarasi Das Univ, Sch Appl Sci, Dept Chem, Faizabad Rd, Lucknow 226028, Uttar Pradesh, India
关键词
Polychlorinated biphenyls; Organochlorine pesticides; US-DLLME-SFO; Design of experiment; Fish liver; GC-mu ECD; SOLID-PHASE-MICROEXTRACTION; POLYCYCLIC AROMATIC-HYDROCARBONS; SUPERCRITICAL-FLUID EXTRACTION; POLYCHLORINATED-BIPHENYLS PCBS; TANDEM MASS-SPECTROMETRY; PESTICIDES OCPS; WATER SAMPLES; EMULSIFICATION-MICROEXTRACTION; EXPERIMENTAL-DESIGN; EDIBLE FISH;
D O I
10.1016/j.chroma.2018.05.035
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple and rapid method for the extraction of organochlorine compounds (OCs) including polychlorinated biphenyls (PCBs) and organochlorine pesticides (OCPs) in fish liver using ultrasound assisted dispersive liquid-liquid microextraction based on the solidification of floating organic droplet (US-DLLME-SFO) was developed. For reducing the complexity of the matrix, the sample was pre-treated prior to microextraction. Factors affecting US-DLLME-SFO were optimized by using statistical design of experiment (DoE). The analysis was carried out by Gas Chromatography (GC) equipped with micro electron capture detector (mu-ECD). The optimized parameters were 4.8 min of ultrasound, 3.0 mL of Milli-Q and 24 mu L of 1-undecanol as an extraction solvent as determined by DoE. US-DLLME-SFO was validated in terms of limit of detection, limit of quantification, dynamic linearity range, coefficient of determination (linearity) and extraction recovery in fish liver for OCs, and the respective values were (1.06-3.84 ng g(-1)), (3.50-12.67 ng g(-1)), (1.0-500 ng g(-1)), (R-2 = 0.994-0.999), (88.5-108.4%). Interday and intraday precisions were evaluated as relative standard deviation (% RSD) and the values were <= 10%. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:20 / 27
页数:8
相关论文
共 41 条
  • [11] Capote F. P., 2007, ANAL APPL ULTRASOUND, P26
  • [12] Dispersive liquid-liquid microextraction based on the solidification of floating organic droplet for the determination of polychlorinated biphenyls in aqueous samples
    Dai, Liping
    Cheng, Jing
    Matsadiq, Guzalnur
    Liu, Lu
    Li, Jun-Kai
    [J]. ANALYTICA CHIMICA ACTA, 2010, 674 (02) : 201 - 205
  • [13] Simultaneous analysis of polychlorinated biphenyls and organochlorine pesticides in water by headspace solid-phase microextraction with gas chromatography-tandem mass spectrometry
    Derouiche, Abdelkader
    Driss, Mohamed Ridha
    Morizur, Jean-Pierre
    Taphanel, Marie-Helene
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2007, 1138 (1-2) : 231 - 243
  • [14] PCB CONGENERS, HEXACHLOROBENZENE, AND ORGANOCHLORINE INSECTICIDES IN HUMAN FAT IN ITALY
    FOCARDI, S
    FOSSI, C
    LEONZIO, C
    ROMEI, R
    [J]. BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 1986, 36 (05) : 644 - 650
  • [15] Guide Eurchem., 2014, The Fitness for Purpose of Analytical Methods
  • [16] Supercritical fluid extraction with solid-phase trapping of chlorinated and brominated pollutants from sediment samples
    Hartonen, K
    Bowadt, S
    Hawthorne, SB
    Riekkola, ML
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1997, 774 (1-2) : 229 - 242
  • [17] Solid-Phase-Microextraction Measurement of 62 Polychlorinated Biphenyl Congeners in Milliliter Sediment Pore Water Samples and Determination of KDOC Values
    Hawthorne, Steven B.
    Grabanski, Carol B.
    Miller, David J.
    [J]. ANALYTICAL CHEMISTRY, 2009, 81 (16) : 6936 - 6943
  • [18] Dispersive liquid-liquid microextraction followed by gas chromatography-electron capture detection for determination of polychlorinated biphenyls in fish
    Hu, Jia
    Li, Yanyan
    Zhang, Wei
    Wang, Huili
    Huang, Changjiang
    Zhang, Minghua
    Wang, Xuedong
    [J]. JOURNAL OF SEPARATION SCIENCE, 2009, 32 (12) : 2103 - 2108
  • [19] Dispersive liquid-liquid microextraction combined with gas chromatography-electron capture detection for the determination of polychlorinated biphenyls in soils
    Hu, Jia
    Fu, Lingyan
    Zhao, Xinna
    Liu, Xiujuan
    Wang, Huili
    Wang, Xuedong
    Dai, Liyan
    [J]. ANALYTICA CHIMICA ACTA, 2009, 640 (1-2) : 100 - 105
  • [20] Polychlorinated biphenyls (PCBs) and organochlorine pesticides (OCPs) in the sediments of an Italian drinking water reservoir
    Kalajzic, T
    Bianchi, M
    Muntau, H
    Kettrup, A
    [J]. CHEMOSPHERE, 1998, 36 (07) : 1615 - 1625