Determination of organochlorine compounds in fish liver by ultrasound-assisted dispersive liquid-liquid microextraction based on solidification of organic droplet coupled with gas chromatography-electron capture detection

被引:25
作者
Asati, Ankita [1 ,2 ]
Satyanarayana, G. N. V. [2 ,3 ]
Srivastava, V. Tanmya [2 ]
Patel, Devendra K. [1 ,2 ]
机构
[1] Acad Sci & Innovat Res AcSIR, CSIR IITR Campus, Lucknow, Uttar Pradesh, India
[2] CSIR Indian Inst Toxicol Res, Analyt Chem Lab, Regulatory Toxicol Grp, Vishvigyan Bhawan 31,Mahatma Gandhi Marg, Lucknow 226001, Uttar Pradesh, India
[3] Babu Banarasi Das Univ, Sch Appl Sci, Dept Chem, Faizabad Rd, Lucknow 226028, Uttar Pradesh, India
关键词
Polychlorinated biphenyls; Organochlorine pesticides; US-DLLME-SFO; Design of experiment; Fish liver; GC-mu ECD; SOLID-PHASE-MICROEXTRACTION; POLYCYCLIC AROMATIC-HYDROCARBONS; SUPERCRITICAL-FLUID EXTRACTION; POLYCHLORINATED-BIPHENYLS PCBS; TANDEM MASS-SPECTROMETRY; PESTICIDES OCPS; WATER SAMPLES; EMULSIFICATION-MICROEXTRACTION; EXPERIMENTAL-DESIGN; EDIBLE FISH;
D O I
10.1016/j.chroma.2018.05.035
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple and rapid method for the extraction of organochlorine compounds (OCs) including polychlorinated biphenyls (PCBs) and organochlorine pesticides (OCPs) in fish liver using ultrasound assisted dispersive liquid-liquid microextraction based on the solidification of floating organic droplet (US-DLLME-SFO) was developed. For reducing the complexity of the matrix, the sample was pre-treated prior to microextraction. Factors affecting US-DLLME-SFO were optimized by using statistical design of experiment (DoE). The analysis was carried out by Gas Chromatography (GC) equipped with micro electron capture detector (mu-ECD). The optimized parameters were 4.8 min of ultrasound, 3.0 mL of Milli-Q and 24 mu L of 1-undecanol as an extraction solvent as determined by DoE. US-DLLME-SFO was validated in terms of limit of detection, limit of quantification, dynamic linearity range, coefficient of determination (linearity) and extraction recovery in fish liver for OCs, and the respective values were (1.06-3.84 ng g(-1)), (3.50-12.67 ng g(-1)), (1.0-500 ng g(-1)), (R-2 = 0.994-0.999), (88.5-108.4%). Interday and intraday precisions were evaluated as relative standard deviation (% RSD) and the values were <= 10%. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:20 / 27
页数:8
相关论文
共 41 条
  • [1] Dioxin-like PCBs in the environment - Human exposure and the significance of sources
    Alcock, RE
    Behnisch, PA
    Jones, KC
    Hagenmaier, H
    [J]. CHEMOSPHERE, 1998, 37 (08) : 1457 - 1472
  • [2] [Anonymous], 1951, BREAKTHROUGHS STAT, DOI DOI 10.1007/978-1-4612-4380-9_23
  • [3] Comparison of two microextraction methods based on solidification of floating organic droplet for the determination of multiclass analytes in river water samples by liquid chromatography tandem mass spectrometry using Central Composite Design
    Asati, Ankita
    Satyanarayana, G. N. V.
    Patel, Devendra K.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2017, 1513 : 157 - 171
  • [4] Ionic liquid based vortex assisted liquid-liquid microextraction combined with liquid chromatography mass spectrometry for the determination of bisphenols in thermal papers with the aid of response surface methodology
    Asati, Ankita
    Satyanarayana, G. N. V.
    Panchal, Smita
    Thakur, Ravindra Singh
    Ansari, Nasreen G.
    Patel, Devendra K.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2017, 1509 : 35 - 42
  • [5] Vortex-assisted surfactant-enhanced emulsification microextraction combined with LC-MS/MS for the determination of glucocorticoids in water with the aid of experimental design
    Asati, Ankita
    Satyanarayana, G. N. V.
    Patel, Devendra K.
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2017, 409 (11) : 2905 - 2918
  • [6] Application of liquid-phase microextraction and gas chromatography-mass spectrometry for the determination of polychlorinated biphenyls in blood plasma
    Basheer, C
    Lee, HK
    Obbard, JP
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2004, 1022 (1-2) : 161 - 169
  • [7] THE NEED FOR ADEQUATE BIOLOGICAL SAMPLING IN ECOTOXICOLOGICAL INVESTIGATIONS - A RETROSPECTIVE STUDY OF 20 YEARS POLLUTION MONITORING
    BIGNERT, A
    GOTHBERG, A
    JENSEN, S
    LITZEN, K
    ODSJO, T
    OLSSON, M
    REUTERGARDH, L
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 1993, 128 (2-3) : 121 - 139
  • [8] INDEPENDENT COMPARISON OF SOXHLET AND SUPERCRITICAL-FLUID EXTRACTION FOR THE DETERMINATION OF PCBS IN AN INDUSTRIAL SOIL
    BOWADT, S
    JOHANSSON, B
    WUNDERLI, S
    ZENNEGG, M
    DEALENCASTRO, LF
    GRANDJEAN, D
    [J]. ANALYTICAL CHEMISTRY, 1995, 67 (14) : 2424 - 2430
  • [9] MULTI-FACTOR EXPERIMENTAL-DESIGNS FOR EXPLORING RESPONSE SURFACES
    BOX, GEP
    HUNTER, JS
    [J]. ANNALS OF MATHEMATICAL STATISTICS, 1957, 28 (01): : 195 - 241
  • [10] Report of the WHO working group on the assessment of health risks for human infants from exposure to PCDDs, PCDFs and PCBs.
    Brouwer, A
    Ahlborg, UG
    van Leeuwen, FXR
    Feeley, MM
    [J]. CHEMOSPHERE, 1998, 37 (9-12) : 1627 - 1643