Hamstring tendon fixation using interference screws: A biomechanical study in calf tibial bone

被引:163
作者
Weiler, A
Hoffmann, RFG
Stahelin, AC
Bail, HJ
Siepe, CJ
Sudkamp, NP
机构
[1] Humboldt Univ, Klinikum Rudolf Virchow, D-13353 Berlin, Germany
[2] Orthopaed Surg FMH, Basel, Switzerland
来源
ARTHROSCOPY | 1998年 / 14卷 / 01期
关键词
anterior cruciate ligament; hamstring tendons; biodegradable; poly-(D; L-lactide); interference screw; pullout force;
D O I
10.1016/S0749-8063(98)70117-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
It has recently been shown that graft fixation close to the ACL insertion site is optimal in order to increase anterior knee stability. Hamstring tendon fixation using interference screws offers this possibility and a round threaded titanium interference screw has been previously developed. The use of a round threaded biodegradable interference screw may be equivalent. In addition, to increase initial fixation strength, graft harvest with a distally attached bone plug may be advantageous, but biomechanical data do not exist. This study compares the initial pullout force, stiffness of fixation, and failure modes of three strand semitendinosus grafts in 36 proximal calf tibiae using either biodegradable poly-(D,L-lactide) (Sysorb; Sulzer Orthopaedics Ltd, Munsingen, Switzerland) or round threaded titanium (RCI; Smith & Nephew DonJoy, Carlsbad, CA) interference screws, harvested either without (biodegradable: group I, titanium III) or with (biodegradable: group II, titanium: group IV) attached tibial bone plugs. Maximum pullout force in group I (507 +/- 93 N) was significantly higher than in group III (419 +/- 77 N). Pullout force of bone plug fixation was significantly higher than that of direct tendon fixation (717 +/- 90 N in group II and 602 +/- 117 N in group TV). Pullout force of biodegradable fixation was significantly higher in both settings. These results indicate that initial pullout force of hamstring-tendon graft interference screw fixation can be increased by using a biodegradable interference screw. In addition, initial pullout force of hamstring-tendon graft fixation with an interference screw can be greatly increased by harvesting the graft with its distally attached tibial bone plug.
引用
收藏
页码:29 / 37
页数:9
相关论文
共 79 条
[1]   PATELLAR TENDON VERSUS DOUBLED SEMITENDINOSUS AND GRACILIS TENDONS FOR ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION [J].
AGLIETTI, P ;
BUZZI, R ;
ZACCHEROTTI, G ;
DEBIASE, P .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1994, 22 (02) :211-218
[2]  
AGLIETTI P, 1993, CLIN ORTHOP RELAT R, P195
[3]   THE STRENGTH OF ARTIFICIAL LIGAMENT ANCHORAGES - A COMPARATIVE EXPERIMENTAL-STUDY [J].
AMIS, AA .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1988, 70 (03) :397-403
[4]  
BARBER F, 1995, ARTHROSCOPY, V11, P573
[5]  
BARBER FA, 1991, AM J KNEE SURG, V4, P84
[6]   RUPTURE OF THE PATELLAR LIGAMENT AFTER USE OF ITS CENTRAL 3RD FOR ANTERIOR CRUCIATE RECONSTRUCTION - A REPORT OF 2 CASES [J].
BONAMO, JJ ;
KRINICK, RM ;
SPORN, AA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1984, 66A (08) :1294-1297
[7]  
Bonatus T J, 1991, Orthop Rev, V20, P770
[8]  
BOUCHARD C, 1993, CLIN J SPORT MED, V3, P118
[9]  
BROWN C, 1995, P SPORTS MED 2000
[10]  
BROWN CH, 1993, CLIN SPORT MED, V12, P723