Quantification of Regional Myocardial Oxygenation by Magnetic Resonance Imaging Validation With Positron Emission Tomography

被引:25
|
作者
McCommis, Kyle S. [1 ]
Goldstein, Thomas A. [1 ]
Abendschein, Dana R. [2 ]
Herrero, Pilar [1 ]
Misselwitz, Bernd [3 ]
Gropler, Robert J. [1 ]
Zheng, Jie [1 ]
机构
[1] Washington Univ, Sch Med, Mallinckrodt Inst Radiol, St Louis, MO 63110 USA
[2] Washington Univ, Sch Med, Cardiovasc Res Ctr, St Louis, MO 63110 USA
[3] Bayer Schering Pharma AG, Berlin, Germany
基金
美国国家卫生研究院;
关键词
MRI; perfusion; ischemia; oxygen consumption; BLOOD-FLOW; SUSCEPTIBILITY CONTRAST; PERFUSION; MRI; DIPYRIDAMOLE; CONSUMPTION; STRESS; VOLUME; RESERVE; MODEL;
D O I
10.1161/CIRCIMAGING.109.897546
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-A comprehensive evaluation of myocardial ischemia requires measures of both oxygen supply and demand. Positron emission tomography (PET) is currently the gold standard for such evaluations, but its use is limited because of its ionizing radiation, limited availability, and high cost. A cardiac MRI method was developed for assessing myocardial oxygenation. The purpose of this study was to evaluate and validate this technique compared with PET during pharmacological stress in a canine model of coronary artery stenosis. Methods and Results-Twenty-one beagles and small mongrel dogs without coronary artery stenosis (controls) or with moderate to severe acute coronary artery stenosis underwent MRI and PET imaging at rest and during dipyridamole vasodilation or dobutamine stress to induce a wide range of changes in cardiac perfusion and oxygenation. MRI first-pass perfusion imaging was performed to quantify myocardial blood flow and volume. The MRI blood oxygen level-dependent technique was used to determine the myocardial oxygen extraction fraction during pharmacological hyperemia. Myocardial oxygen consumption was determined by the Fick law. In the same dogs, O-15-water and C-11-acetate were used to measure myocardial blood flow and myocardial oxygen consumption, respectively, by PET. Regional assessments were performed for both MR and PET. MRI data correlated nicely with PET values for myocardial blood flow (R-2 = 0.79, P <0.001), myocardial oxygen consumption (R-2=0.74, P<0.001), and oxygen extraction fraction (R-2=0.66, P<0.01). Conclusions-Cardiac MRI methods may provide an alternative to radionuclide imaging in settings of myocardial ischemia. Our newly developed quantitative MRI oxygenation imaging technique may be a valuable noninvasive tool to directly evaluate myocardial energetics and efficiency. (Circ Cardiovasc Imaging. 2010;3:41-46.)
引用
收藏
页码:41 / U60
页数:9
相关论文
共 50 条
  • [31] Added prognostic value of myocardial blood flow quantitation in rubidium-82 positron emission tomography imaging
    Farhad, Hoshang
    Dunet, Vincent
    Bachelard, Kim
    Allenbach, Gilles
    Kaufmann, Philipp A.
    Prior, John O.
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2013, 14 (12) : 1203 - 1210
  • [32] A Welcomed New Myocardial Perfusion Imaging Agent for Positron Emission Tomography
    Beller, George A.
    Watson, Denny D.
    CIRCULATION, 2009, 119 (17) : 2299 - 2301
  • [33] Review of cardiovascular imaging in the Journal of Nuclear Cardiology 2018. Part 1 of 2: Positron emission tomography, computed tomography, and magnetic resonance
    AlJaroudi, Wael A.
    Hage, Fadi G.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2019, 26 (02) : 524 - 535
  • [34] IMAGING OF MYOCARDIAL-METABOLISM BY POSITRON EMISSION TOMOGRAPHY
    RIGO, P
    DELANDSHEERE, C
    MELON, P
    KULBERTUS, H
    CARDIOVASCULAR DRUGS AND THERAPY, 1990, 4 : 847 - 852
  • [35] Magnetic Resonance Stress Imaging of Myocardial Perfusion and Wall Motion
    Kawel-Boehm, Nadine
    Bremerich, Jens
    JOURNAL OF THORACIC IMAGING, 2014, 29 (01) : 30 - 37
  • [36] Quantitative Assessment of Myocardial Ischemia With Positron Emission Tomography
    Sohn, Jae Ho
    Behr, Spencer C.
    Pampaloni, Miguel Hernandez
    Seo, Youngho
    JOURNAL OF THORACIC IMAGING, 2023, 38 (04) : 247 - 259
  • [37] Does the mismatch match the penumbra? Magnetic resonance imaging and positron emission tomography in early ischemic stroke
    Sobesky, J
    Zaro-Weber, O
    Lehnhardt, FG
    Hesselmann, V
    Neveling, M
    Jacobs, A
    Heiss, WD
    STROKE, 2005, 36 (05) : 980 - 985
  • [38] Combined Positron Emission Tomography and Magnetic Resonance as Translational Tool in Cardiology
    Schwaiger, Markus
    CIRCULATION-CARDIOVASCULAR IMAGING, 2016, 9 (03)
  • [39] Interest of positron-emission tomography and magnetic resonance imaging for radiotherapy planning and control
    Crehange, G.
    Soussan, M.
    Gensanne, D.
    Decazes, P.
    Thariat, J.
    Thureau, S.
    CANCER RADIOTHERAPIE, 2020, 24 (05): : 398 - 402
  • [40] A Baboon Brain Atlas for Magnetic Resonance Imaging and Positron Emission Tomography Image Analysis
    Agaronyan, Artur
    Syed, Raeyan
    Kim, Ryan
    Hsu, Chao-Hsiung
    Love, Scott A.
    Hooker, Jacob M.
    Reid, Alicia E.
    Wang, Paul C.
    Ishibashi, Nobuyuki
    Kang, Yeona
    Tu, Tsang-Wei
    FRONTIERS IN NEUROANATOMY, 2022, 15