On the use of water phantom images to calibrate and correct eddy current induced artefacts in MR diffusion tensor imaging

被引:44
作者
Bastin, ME [1 ]
Armitage, PA [1 ]
机构
[1] Univ Edinburgh, Western Gen Hosp, Dept Med Phys & Med Engn, Edinburgh EH4 2XU, Midlothian, Scotland
关键词
diffusion; echo-planar; distortion; warping;
D O I
10.1016/S0730-725X(00)00158-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The accurate determination of absolute measures of diffusion anisotropy in vivo using single-shot, echo-planar imaging techniques requires the acquisition of a set of high signal-to-noise ratio, diffusion-weighted images that are free from eddy current induced image distortions. Such geometric distortions can be characterized and corrected in brain imaging data using magnification (M), translation (T), and shear (S) distortion parameters derived from separate water phantom calibration experiments. Here we examine the practicalities of using separate phantom calibration data to correct high b-value diffusion tensor imaging data by investigating the stability of these distortion parameters, and hence the eddy currents, with time. It is found that M, T, and S vary only slowly with time (i.e., on the order of weeks), so that calibration scans need not be performed after every patient examination. This not only minimises the scan time required to collect the calibration data, but also the computational time needed to characterize these eddy current induced distortions. Examples of how measurements of diffusion anisotropy are improved using this post-processing scheme are also presented. (C) 2000 Elsevier Science Inc. All rights reserved.
引用
收藏
页码:681 / 687
页数:7
相关论文
共 23 条
[1]   Elimination of eddy current artifacts in diffusion-weighted echo-planar images: The use of bipolar gradients [J].
Alexander, AL ;
Tsuruda, JS ;
Parker, DL .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (06) :1016-1021
[2]  
BASSER P, 1996, J MAGN RESON SER B, V11, P209
[3]   A simplified method to measure the diffusion tensor from seven MR images [J].
Basser, PJ ;
Pierpaoli, C .
MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (06) :928-934
[4]   Inferring microstructural features and the physiological state of tissues from diffusion-weighted images [J].
Basser, PJ .
NMR IN BIOMEDICINE, 1995, 8 (7-8) :333-344
[5]   ESTIMATION OF THE EFFECTIVE SELF-DIFFUSION TENSOR FROM THE NMR SPIN-ECHO [J].
BASSER, PJ ;
MATTIELLO, J ;
LEBIHAN, D .
JOURNAL OF MAGNETIC RESONANCE SERIES B, 1994, 103 (03) :247-254
[6]   Correction of eddy current-induced artefacts in diffusion tensor imaging using iterative cross-correlation [J].
Bastin, ME .
MAGNETIC RESONANCE IMAGING, 1999, 17 (07) :1011-1024
[7]  
Calamante F, 1999, MAGN RESON MED, V41, P95, DOI 10.1002/(SICI)1522-2594(199901)41:1<95::AID-MRM14>3.0.CO
[8]  
2-T
[9]  
Cercignani M, 1999, J MAGN RESON, V140, P58, DOI 10.1006/jmre/1999.1830
[10]  
DECRESPIGNY AJ, 1998, 6 ANN M INT SOC MAGN, V1, P661