A CORRELATION BETWEEN BONE (B), INSERTION TORQUE (IT), AND IMPLANT STABILITY (S): BITS SCORE

被引:37
作者
Herekar, Manisha [1 ]
Sethi, Megha [1 ]
Ahmad, Tousif [1 ]
Fernandes, Aquaviva Sebasteao
Patil, Viraj [1 ]
Kulkarni, Harish [2 ]
机构
[1] Maratha Mandals Nathajirao G Halgekar Inst Dent S, Dept Prosthodont, Belgaum, Karnataka, India
[2] Tatyasaheb Kore Dent Coll & Res Ctr, Dept Oral & Maxillofacial Surg, Warnanagar, Maharashtra, India
关键词
RESONANCE FREQUENCY-ANALYSIS; COMPUTERIZED-TOMOGRAPHY VALUES; BIOMECHANICAL ASPECTS; ENDOSSEOUS IMPLANTS; TITANIUM IMPLANTS; DENSITY; PLACEMENT;
D O I
10.1016/j.prosdent.2014.02.011
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Although criteria for assessing bone quality have been reported, an overall score that correlates bone quality with the primary stability and secondary stability of implants is not yet available. Purpose. The purpose of this article was to propose a scoring index that will establish a correlation among the bone density values from computed tomography, maximum insertion torque values, and resonance frequency analysis in different phases of implant treatment. Material and methods. In this study, 60 implant sites were evaluated to assess bone density (Hounsfield units), insertion torque values (Ncm), and primary stability and secondary stability (implant stability quotient values obtained by using resonance frequency analysis). On the basis of computed tomography data, the bone was classified as D1 to D4. The insertion torque was noted and classified into 2 groups, A and B. The implant stability quotient values obtained from resonance frequency analysis depicting primary stability and secondary stability were classified into 5 groups. The primary score noted was a result of the values obtained for the 3 parameters at the time of implant placement. The secondary score was obtained by considering the values of the bone density and resonance frequency analysis recorded at different time intervals. Results. Bone densities of D2, D3, and D4 were noted, dividing the bone type into 3 groups. The maximum torque noted in the study was 40 Ncm. The difference between various insertion torque values and bone types was found to be statistically nonsignificant. Higher mean implant stability quotient values were obtained for primary and secondary stability for the D2 bone than for D3 and D4 bone. When analyzed according to the time of insertion, the mean values increased at second stage surgery in all bone types. The difference in mean values among all bone types was found to be statistically significant (P<.001). A comparison of primary and secondary implant stability quotient values in all bone types did not find any statistical significance (P=.780). A score was recorded at the time of implant placement and at the time of second stage surgery, and the prosthetic treatment was planned accordingly. Conclusions. The score highlight the importance of considering the association of bone quality, insertion torque values, and stability as denoted by implant stability quotient throughout treatment. Based on the variation. in the score noted at recall visits, alterations in the treatment plan can be made with respect to the healing period and prosthetic design.
引用
收藏
页码:805 / 810
页数:6
相关论文
共 50 条
  • [41] Assessment of correlation between computerized tomography values of the bone, and maximum torque and resonance frequency values at dental implant placement
    Turkyilmaz, I.
    Toezuem, T. F.
    Tumer, C.
    Ozbek, E. N.
    JOURNAL OF ORAL REHABILITATION, 2006, 33 (12) : 881 - 888
  • [42] Bone tissue microarchitectural characteristics at dental implant sites part 2: correlation with bone classification and primary stability
    Ribeiro-Rotta, Rejane Faria
    Gomes de Oliveira, Rubelisa Candido
    Dias, Danilo Rocha
    Lindh, Christina
    Leles, Claudio Rodrigues
    CLINICAL ORAL IMPLANTS RESEARCH, 2014, 25 (02) : E47 - E53
  • [43] A Comparative Study of Crestal Bone Loss and Implant Stability between Osteotome and Conventional Implant Insertion Techniques: A Randomized Controlled Clinical Trial Study
    Shayesteh, Yadollah Soleimani
    Khojasteh, Arash
    Siadat, Hakimeh
    Monzavi, Abbas
    Bassir, Seyed Hossein
    Hossaini, Mehran
    Alikhasi, Marzieh
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2013, 15 (03) : 350 - 357
  • [44] ASSOCIATION BETWEEN PERI IMPLANT CRESTAL BONE LOSS AND INSERTION TORQUE IN IMPLANTS PLACED IN EDENTULOUS MAXILLA AND MANDIBLE- A RETROSPECTIVE ANALYSIS
    Ramamoorthy, Jagadheeswari
    Rajasekar, Arvina
    INTERNATIONAL JOURNAL OF MEDICAL DENTISTRY, 2023, 27 (01) : 128 - 133
  • [45] Correlation Between Bone Quality Evaluated by Cone-Beam Computerized Tomography and Implant Primary Stability
    Song, Young-Dai
    Jun, Sang-Ho
    Kwon, Jong-Jin
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2009, 24 (01) : 59 - 64
  • [46] A New Site Preparation Protocol That Supports Bone Quality Evaluation and Provides Predictable Implant Insertion Torque
    Velikov, Stefan
    Susin, Cristiano
    Heuberger, Peter
    Irastorza-Landa, Ainara
    JOURNAL OF CLINICAL MEDICINE, 2020, 9 (02)
  • [47] The correlation of CBCT analysis derived bone density parameters with primary implant stability - a clinical study
    Mikic, Mirko
    Vlahovic, Zoran
    Nenezic, Dragoslav
    Videnovic, Goran
    Ilic, Danijela
    Mladenovic, Rasa
    VOJNOSANITETSKI PREGLED, 2021, 78 (08) : 811 - 817
  • [48] The effects of implant design, bone quality, and insertion process on primary stability of dental implants: an in-vitro study
    Rismanchian, Mansour
    Afshari, Mojtaba
    INTERNATIONAL JOURNAL OF BIOMEDICAL ENGINEERING AND TECHNOLOGY, 2020, 34 (04) : 319 - 333
  • [49] Strain of bone-implant interface and insertion torque regarding different miniscrew thread designs using an artificial bone model
    Cha, Jung-Yul
    Hwang, Chung-Ju
    Kwon, Sung Hwang
    Jung, Han-Sung
    Kim, Kwang-Mahn
    Yu, Hyung Seog
    EUROPEAN JOURNAL OF ORTHODONTICS, 2015, 37 (03) : 268 - 274
  • [50] Clinical study of the relationship between implant stability measurements using Periotest and Osstell mentor and bone quality assessment
    Oh, Ji-Su
    Kim, Su-Gwan
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2012, 113 (03): : E35 - E40