A CORRELATION BETWEEN BONE (B), INSERTION TORQUE (IT), AND IMPLANT STABILITY (S): BITS SCORE

被引:37
作者
Herekar, Manisha [1 ]
Sethi, Megha [1 ]
Ahmad, Tousif [1 ]
Fernandes, Aquaviva Sebasteao
Patil, Viraj [1 ]
Kulkarni, Harish [2 ]
机构
[1] Maratha Mandals Nathajirao G Halgekar Inst Dent S, Dept Prosthodont, Belgaum, Karnataka, India
[2] Tatyasaheb Kore Dent Coll & Res Ctr, Dept Oral & Maxillofacial Surg, Warnanagar, Maharashtra, India
关键词
RESONANCE FREQUENCY-ANALYSIS; COMPUTERIZED-TOMOGRAPHY VALUES; BIOMECHANICAL ASPECTS; ENDOSSEOUS IMPLANTS; TITANIUM IMPLANTS; DENSITY; PLACEMENT;
D O I
10.1016/j.prosdent.2014.02.011
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Although criteria for assessing bone quality have been reported, an overall score that correlates bone quality with the primary stability and secondary stability of implants is not yet available. Purpose. The purpose of this article was to propose a scoring index that will establish a correlation among the bone density values from computed tomography, maximum insertion torque values, and resonance frequency analysis in different phases of implant treatment. Material and methods. In this study, 60 implant sites were evaluated to assess bone density (Hounsfield units), insertion torque values (Ncm), and primary stability and secondary stability (implant stability quotient values obtained by using resonance frequency analysis). On the basis of computed tomography data, the bone was classified as D1 to D4. The insertion torque was noted and classified into 2 groups, A and B. The implant stability quotient values obtained from resonance frequency analysis depicting primary stability and secondary stability were classified into 5 groups. The primary score noted was a result of the values obtained for the 3 parameters at the time of implant placement. The secondary score was obtained by considering the values of the bone density and resonance frequency analysis recorded at different time intervals. Results. Bone densities of D2, D3, and D4 were noted, dividing the bone type into 3 groups. The maximum torque noted in the study was 40 Ncm. The difference between various insertion torque values and bone types was found to be statistically nonsignificant. Higher mean implant stability quotient values were obtained for primary and secondary stability for the D2 bone than for D3 and D4 bone. When analyzed according to the time of insertion, the mean values increased at second stage surgery in all bone types. The difference in mean values among all bone types was found to be statistically significant (P<.001). A comparison of primary and secondary implant stability quotient values in all bone types did not find any statistical significance (P=.780). A score was recorded at the time of implant placement and at the time of second stage surgery, and the prosthetic treatment was planned accordingly. Conclusions. The score highlight the importance of considering the association of bone quality, insertion torque values, and stability as denoted by implant stability quotient throughout treatment. Based on the variation. in the score noted at recall visits, alterations in the treatment plan can be made with respect to the healing period and prosthetic design.
引用
收藏
页码:805 / 810
页数:6
相关论文
共 50 条
  • [31] Relation between initial implant stability quotient and bone-implant contact percentage: an in vitro model study
    Huang, Heng-Li
    Tsai, Ming-Tzu
    Su, Kuo-Chih
    Li, Yu-Fen
    Hsu, Jui-Ting
    Chang, Chih-Han
    Fuh, Lih-Jyh
    Wu, Aaron Yu-Jen
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2013, 116 (05): : E356 - E361
  • [32] Relationship between cortical bone thickness and implant stability at the time of surgery and secondary stability after osseointegration measured using resonance frequency analysis
    Tanaka, Kenko
    Sailer, Irena
    Iwama, Ryosuke
    Yamauchi, Kensuke
    Nogami, Shinnosuke
    Yoda, Nobuhiro
    Takahashi, Tetsu
    JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, 2018, 48 (06) : 360 - 372
  • [33] Relationship between the CT Value and Cortical Bone Thickness at Implant Recipient Sites and Primary Implant Stability with Comparison of Different Implant Types
    Howashi, Miori
    Tsukiyama, Yoshihiro
    Ayukawa, Yasunori
    Isoda-Akizuki, Kei
    Kihara, Masafumi
    Imai, Yu
    Sogo, Motofumi
    Koyano, Kiyoshi
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2016, 18 (01) : 107 - 116
  • [34] Evaluation of the insertion torque, implant stability quotient and drilled hole quality for different drill design: an invitro Investigation
    Alexandre Gehrke, Sergio
    Calvo Guirado, Jose Luis
    Bettach, Raphael
    Del Fabbro, Massimo
    Perez-Albacete Martinez, Carlos
    Shibli, Jamil Awad
    CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 (06) : 656 - 662
  • [35] Correlation of Bone Vascularity in the Posterior Mandible and Subsequent Implant Stability: A Preliminary Study
    Kokovic, Vladimir
    Krsljak, Elena
    Andric, Miroslav
    Brkovic, Bozidar
    Milicic, Biljana
    Jurisic, Milan
    Rahman, Muhammed Mustahsen
    Haemmerle, Christoph H. F.
    IMPLANT DENTISTRY, 2014, 23 (02) : 200 - 205
  • [36] Correlation Between Resonance Frequency Analysis and Bone Quality Assessments at Dental Implant Recipient Sites
    Fu, Min-Wen
    Fu, Earl
    Lin, Fu-Gong
    Chang, Wei-Jeng
    Hsieh, Yao-Dung
    Shen, E-Chin
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (01) : 180 - 187
  • [37] The Influence of Low Insertion Torque on Primary Stability, Implant Survival, and Maintenance of Marginal Bone Levels: A Closed-Cohort Prospective Study
    Norton, Michael R.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (04) : 849 - 857
  • [38] Relationship between implant primary stability (torque and ISQ) and bone density assessed by CBCT-clinical trial
    Gomes, R. Z.
    Lopes da Silva, L.
    Coimbra, J.
    Guerra, I.
    Vasconcelos, M.
    Correia, A.
    Braga, A. C.
    BIODENTAL ENGINEERING III, 2014, : 125 - 130
  • [39] Randomized Clinical Trial Comparing Insertion Torque and Implant Stability of Two Different Implant Macrogeometries in the Initial Periods of Osseointegration
    Gehrke, Sergio Alexandre
    Cortellari, Guillermo Castro
    Fernandes, Gustavo Vicentis de Oliveira
    Scarano, Antonio
    Martins, Rafael Garcia
    Cancado, Renata Moreira
    Mesquita, Alfredo Mikail Melo
    MEDICINA-LITHUANIA, 2023, 59 (01):
  • [40] The relationship between implant stability quotient values and implant insertion variables: a clinical study
    Park, K-J
    Kwon, J-Y
    Kim, S-K
    Heo, S-J
    Koak, J-Y
    Lee, J-H
    Lee, S-J
    Kim, T-H
    Kim, M-J
    JOURNAL OF ORAL REHABILITATION, 2012, 39 (02) : 151 - 159