A CORRELATION BETWEEN BONE (B), INSERTION TORQUE (IT), AND IMPLANT STABILITY (S): BITS SCORE

被引:37
作者
Herekar, Manisha [1 ]
Sethi, Megha [1 ]
Ahmad, Tousif [1 ]
Fernandes, Aquaviva Sebasteao
Patil, Viraj [1 ]
Kulkarni, Harish [2 ]
机构
[1] Maratha Mandals Nathajirao G Halgekar Inst Dent S, Dept Prosthodont, Belgaum, Karnataka, India
[2] Tatyasaheb Kore Dent Coll & Res Ctr, Dept Oral & Maxillofacial Surg, Warnanagar, Maharashtra, India
关键词
RESONANCE FREQUENCY-ANALYSIS; COMPUTERIZED-TOMOGRAPHY VALUES; BIOMECHANICAL ASPECTS; ENDOSSEOUS IMPLANTS; TITANIUM IMPLANTS; DENSITY; PLACEMENT;
D O I
10.1016/j.prosdent.2014.02.011
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Although criteria for assessing bone quality have been reported, an overall score that correlates bone quality with the primary stability and secondary stability of implants is not yet available. Purpose. The purpose of this article was to propose a scoring index that will establish a correlation among the bone density values from computed tomography, maximum insertion torque values, and resonance frequency analysis in different phases of implant treatment. Material and methods. In this study, 60 implant sites were evaluated to assess bone density (Hounsfield units), insertion torque values (Ncm), and primary stability and secondary stability (implant stability quotient values obtained by using resonance frequency analysis). On the basis of computed tomography data, the bone was classified as D1 to D4. The insertion torque was noted and classified into 2 groups, A and B. The implant stability quotient values obtained from resonance frequency analysis depicting primary stability and secondary stability were classified into 5 groups. The primary score noted was a result of the values obtained for the 3 parameters at the time of implant placement. The secondary score was obtained by considering the values of the bone density and resonance frequency analysis recorded at different time intervals. Results. Bone densities of D2, D3, and D4 were noted, dividing the bone type into 3 groups. The maximum torque noted in the study was 40 Ncm. The difference between various insertion torque values and bone types was found to be statistically nonsignificant. Higher mean implant stability quotient values were obtained for primary and secondary stability for the D2 bone than for D3 and D4 bone. When analyzed according to the time of insertion, the mean values increased at second stage surgery in all bone types. The difference in mean values among all bone types was found to be statistically significant (P<.001). A comparison of primary and secondary implant stability quotient values in all bone types did not find any statistical significance (P=.780). A score was recorded at the time of implant placement and at the time of second stage surgery, and the prosthetic treatment was planned accordingly. Conclusions. The score highlight the importance of considering the association of bone quality, insertion torque values, and stability as denoted by implant stability quotient throughout treatment. Based on the variation. in the score noted at recall visits, alterations in the treatment plan can be made with respect to the healing period and prosthetic design.
引用
收藏
页码:805 / 810
页数:6
相关论文
共 50 条
  • [1] The Correlation Between Immediate Implant Insertion Torque and Implant Stability Quotient
    Levin, Barry P.
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2016, 36 (06) : 833 - 840
  • [2] Correlation Between Implant Geometry, Implant Surface, Insertion Torque, and Primary Stability: In Vitro Biomechanical Analysis
    Falco, Antonello
    Berardini, Marco
    Trisi, Paolo
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (04) : 824 - 830
  • [3] Implant Primary Stability Determined by Resonance Frequency Analysis: Correlation With Insertion Torque, Histologic Bone Volume, and Torsional Stability at 6 Weeks
    Makary, Christian
    Rebaudi, Alberto
    Sammartino, Gilberto
    Naaman, Nada
    IMPLANT DENTISTRY, 2012, 21 (06) : 474 - 480
  • [4] Correlation of Radiographic Fractal Analysis with Implant Insertion Torque in a Rabbit Trabecular Bone Model
    Veltri, Mario
    Ferrari, Marco
    Balleri, Piero
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2011, 26 (01) : 108 - 114
  • [5] Resonance Frequency Analysis, Insertion Torque, and Bone to Implant Contact of 4 Implant Surfaces: Comparison and Correlation Study in Sheep
    Dagher, Maroun
    Mokbel, Nadim
    Jabbour, Gabriel
    Naaman, Nada
    IMPLANT DENTISTRY, 2014, 23 (06) : 672 - 678
  • [6] Evaluation of the correlation between insertion torque and primary stability of dental implants using a block bone test
    Bayarchimeg, Dorjpalam
    Namgoong, Hee
    Kim, Byung Kook
    Kim, Myung Duk
    Kim, Sungtae
    Kim, Tae-Il
    Seol, Yang Jo
    Lee, Yong Moo
    Ku, Young
    Rhyu, In-Chul
    Lee, Eun Hee
    Koo, Ki-Tae
    JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, 2013, 43 (01) : 30 - 36
  • [7] Correlation between resonance frequency, insertion torque and bone-implant contact in self-cutting threaded implants
    Acil, Yahya
    Sievers, Jan
    Guelses, Aydin
    Ayna, Mustafa
    Wiltfang, Joerg
    Terheyden, Hendrik
    ODONTOLOGY, 2017, 105 (03) : 347 - 353
  • [8] Insertion Torque Value and Implant Stability Quotient: Separate Evaluation and Correlation for Different Clinical Parameters
    Ferreira, Jose Joaquim Da Rocha
    Machado, Luis Filipe Meira
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2022, 37 (04) : 812 - 822
  • [9] Correlation Between Dental Implant Insertion Torque and Mandibular Alveolar Bone Density in Osteopenic and Osteoporotic Subjects
    Chai, John
    Chau, Anson C. M.
    Chu, Frederick C. S.
    Chow, Tak W.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2012, 27 (04) : 888 - 893
  • [10] A biomechanical assessment of the relation between the oral implant stability at insertion and subjective bone quality assessment
    Alsaadi, Ghada
    Quirynen, Marc
    Michiels, Katleen
    Jacobs, Reinhilde
    van Steenberghe, Daniel
    JOURNAL OF CLINICAL PERIODONTOLOGY, 2007, 34 (04) : 359 - 366