Research and Fabrication of High-Frequency Broadband and Omnidirectional Transmitting Transducer

被引:30
作者
Hao, Shaohua [1 ]
Wang, Hongwei [1 ]
Zhong, Chao [2 ]
Wang, Likun [2 ]
Zhang, Hao [1 ]
机构
[1] Beijing Informat Sci & Technol, Sch Sci, Beijing 100192, Peoples R China
[2] Beijing Informat Sci & Technol Univ, Sensing Technol Res Ctr, Beijing 100101, Peoples R China
基金
中国国家自然科学基金;
关键词
composite materials; multimode coupling; curved-surface forming; high frequency; broadband; horizontal omnidirectional emission; underwater acoustic transducer; ULTRASONIC TRANSDUCER; FINITE-ELEMENT; COMPOSITE; DESIGN;
D O I
10.3390/s18072347
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A wide-band cylindrical transducer was developed by using the wide band of the composite material and the matched matching layer for multimode coupling. Firstly, the structure size of the transducer's sensitive component was designed by using ANSYS simulation software. Secondly, the piezoelectric composite ring-shaped sensitive component was fabricated by the piezoelectric composite curved-surface forming process, and the matching layer was coated on the periphery of the ring-shaped piezoelectric composite material. Finally, it was encapsulated and the electrodes were drawn out to make a high-frequency broadband horizontal omnidirectional water acoustic transducer prototype. After testing, the working frequency range of the transducer was 230-380 kHz, and the maximum transmission voltage response was 168 dB in the water.
引用
收藏
页数:15
相关论文
共 22 条
[1]  
[Anonymous], P IEEE 7 INT S APPL
[2]   Coupled vibration analysis of the thin-walled cylindrical piezoelectric ceramic transducers (vol 125, pg 803, 2009) [J].
Aronov, Boris .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2009, 125 (05) :3467-3467
[3]   Recent advances in 1-3 piezoelectric polymer composite transducer technology for AUV/UUV acoustic Imaging applications [J].
Benjamin, KC .
JOURNAL OF ELECTROCERAMICS, 2002, 8 (02) :145-154
[4]   The design, fabrication, and measured acoustic performance of a 1-3 piezoelectric composite Navy calibration standard transducer [J].
Benjamin, KC ;
Petrie, S .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2001, 109 (05) :1973-1978
[5]  
Butler J. L., 2007, Transducers and Arrays for Underwater Sound
[6]   SIMPLE-MODEL FOR PIEZOELECTRIC CERAMIC POLYMER 1-3 COMPOSITES USED IN ULTRASONIC TRANSDUCER APPLICATIONS [J].
CHAN, HLW ;
UNSWORTH, J .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1989, 36 (04) :434-441
[7]   Multiple acoustical matching layer design of ultrasonic transducer for medical application [J].
Chen, YC ;
Wu, S .
JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2002, 41 (10) :6098-6107
[8]  
Cochran S, 2005, ULTRASON, P231
[9]   Advanced bode plot techniques for ultrasonic transducers [J].
DeAngelis, D. A. ;
Schulze, G. W. .
43RD ANNUAL UIA SYMPOSIUM, 2015, 63 :2-10
[10]   Finite element and experimental study of impedance matching layer optimization [J].
Draheim, MR ;
Cao, WW .
ULTRASONIC TRANSDUCER ENGINEERING: MEDICAL IMAGING 1997, 1997, 3037 :135-139