The effects of an interspinous implant on intervertebral disc pressures

被引:186
作者
Swanson, KE
Lindsey, DP
Hsu, KY
Zucherman, JF
Yerby, SA
机构
[1] St Francis Med Technol, Concord, CA 94520 USA
[2] St Marys Spine Ctr, San Francisco, CA USA
[3] VA Rehab R&D, Palo Alto, CA USA
[4] San Francisco Orthopaed Residency Program, San Francisco, CA USA
关键词
disc pressure; interspinous implant; neurogenic intermittent claudication; spinal stenosis;
D O I
10.1097/00007632-200301010-00008
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. Measurement of intradiscal pressure was performed after placement of an interspinous implant in a cadaver model. Objective. To understand the likelihood of accelerated adjacent-level disc degeneration as a result of the implant. Summary of Background Data. An interspinous implant has been developed to treat lumbar neurogenic claudication secondary to spinal stenosis that places the stenotic segment in slight flexion and prevents extension. Previous biomechanical studies demonstrated that fusing one level may significantly increase the intradiscal pressures at adjacent levels. Moreover, clinical studies have reported an increased incidence of adjacent-level degeneration after lumbar spinal fusion. Methods. Eight cadaver lumbar specimens (L2-L5) were loaded in flexion, neutral, and extension. A pressure transducer measured intradiscal pressure and annular stresses during each of the three positions at each of the three disc levels. An appropriately sized implant was placed at L3-L4 and the pressure measurements were repeated. Results. The pressures at the adjacent discs were not significantly affected by the interspinous implant insertion. There was a significant decrease in intradiscal pressure at the L3-L4 disc in the posterior annulus and nucleus in the neutral and extended positions. Conclusions. The implant does not significantly change the intradiscal pressures at the adjacent levels, yet it significantly unloads the intervertebral disc at the instrumented level in the neutral and extended positions. On the basis of the current findings, it does not appear that the implant causes accelerated disc degeneration at the adjacent levels.
引用
收藏
页码:26 / 32
页数:7
相关论文
共 63 条
  • [1] ADAMS M, 1999, IS LUMBAR SPINE LOAD, P131
  • [2] 'Stress' distributions inside intervertebral discs - The effects of age and degeneration
    Adams, MA
    McNally, DS
    Dolan, P
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1996, 78B (06): : 965 - 972
  • [3] MECHANICAL TESTING OF THE SPINE - AN APPRAISAL OF METHODOLOGY, RESULTS, AND CONCLUSIONS
    ADAMS, MA
    [J]. SPINE, 1995, 20 (19) : 2151 - 2156
  • [4] Effects of backward bending on lumbar intervertebral discs - Relevance to physical therapy treatments for low back pain
    Adams, MA
    May, S
    Freeman, BJC
    Morrison, HP
    Dolan, P
    [J]. SPINE, 2000, 25 (04) : 431 - 437
  • [5] LUMBAR SPINAL STENOSIS - CLINICAL AND RADIOLOGIC FEATURES
    AMUNDSEN, T
    WEBER, H
    LILLEAS, F
    NORDAL, HJ
    ABDELNOOR, M
    MAGNAES, B
    [J]. SPINE, 1995, 20 (10) : 1178 - 1186
  • [6] Andersson G., 1976, SPINE, V1, P178, DOI [10.1097/00007632-197609000-00009, DOI 10.1097/00007632-197609000-00009]
  • [7] ANDERSSON GBJ, 1977, CLIN ORTHOP RELAT R, P156
  • [8] POSTFUSION INSTABILITY AT THE ADJACENT SEGMENTS AFTER RIGID PEDICLE SCREW FIXATION FOR DEGENERATIVE LUMBAR SPINAL-DISORDERS
    AOTA, Y
    KUMANO, K
    HIRABAYASHI, S
    [J]. JOURNAL OF SPINAL DISORDERS, 1995, 8 (06): : 464 - 473
  • [9] ARNOLDI CC, 1976, CLIN ORTHOP RELAT R, P4
  • [10] Effects of short anterior lumbar interbody fusion on biomechanics of neighboring unfused segments
    Chow, DHK
    Luk, KDK
    Evans, JH
    Leong, JCY
    [J]. SPINE, 1996, 21 (05) : 549 - 555