High sensitivity radiochromic film dose comparisons

被引:28
作者
Butson, MJ [1 ]
Yu, PKN
Cheung, T
Metcalfe, P
机构
[1] City Univ Hong Kong, Dept Phys & Mat Sci, Kowloon, Hong Kong, Peoples R China
[2] Dept Med Phys, Illawarra Canc Care Ctr, Wollongong, NSW 2500, Australia
关键词
D O I
10.1088/0031-9155/47/22/402
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This short note investigates the dose characteristics of a relatively new high sensitivity radiochromic film (Gafchromic HS) and compares dose and energy response to various Gafchromic film types and radiographic (EDR-2) film. The original MD-55-1 and two improved sensitivity films, MD-55-2 and HS film, were investigated for energy and dose response. Results show that the energy response of the new HS film is relatively the same as the original MD-55-1 and MD-55-2 films with a decrease in sensitivity at lower x-ray energies, with response decreasing down to approximately 0.64 (normalized to I for a 6 MV beam) for a 28 keV effective energy beam This is compared to an over response of 9.2 at the same energy for EDR-2 film. The dose response at the maximum absorption peak was found to be approximately 3.8 and 1.9 times more sensitive than MD-55-1 and MD-55-2 films, respectively. At the absorption peak yielding the maximum optical density change, HS was found to be approximately 0.2 to 0.25 times the sensitivity of EDR-2.
引用
收藏
页码:N291 / N295
页数:5
相关论文
共 7 条
  • [1] Butson Martin J., 1995, Australasian Physical and Engineering Sciences in Medicine, V18, P133
  • [2] Effects of read-out light sources and ambient light on radiochromic film
    Butson, MJ
    Yu, PKN
    Metcalfe, PE
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (08) : 2407 - 2412
  • [3] A SOLID WATER PHANTOM MATERIAL FOR RADIOTHERAPY X-RAY AND GAMMA-RAY BEAM CALIBRATIONS
    CONSTANTINOU, C
    ATTIX, FH
    PALIWAL, BR
    [J]. MEDICAL PHYSICS, 1982, 9 (03) : 436 - 441
  • [4] GafChromic MD-55: Investigated as a precision dosimeter
    Klassen, NV
    van der Zwan, L
    Cygler, J
    [J]. MEDICAL PHYSICS, 1997, 24 (12) : 1924 - 1934
  • [5] SENSITOMETRY OF THE RESPONSE OF A NEW RADIOCHROMIC FILM DOSIMETER TO GAMMA-RADIATION AND ELECTRON-BEAMS
    MCLAUGHLIN, WL
    YUNDONG, C
    SOARES, CG
    MILLER, A
    VANDYK, G
    LEWIS, DF
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 302 (01) : 165 - 176
  • [6] Dosimetric characteristics of an improved radiochromic film
    Meigooni, AS
    Sanders, MF
    Ibbott, GS
    Szeglin, SR
    [J]. MEDICAL PHYSICS, 1996, 23 (11) : 1883 - 1888
  • [7] Radiochromic film dosimetry: Recommendations of AAPM Radiation Therapy Committee Task Group 55
    Niroomand-Rad, A
    Blackwell, CR
    Coursey, BM
    Gall, KP
    Galvin, JM
    McLaughlin, WL
    Meigooni, AS
    Nath, R
    Rodgers, JE
    Soares, CG
    [J]. MEDICAL PHYSICS, 1998, 25 (11) : 2093 - 2115