Research on the Multiphysics Field-Circuit Coupling Model of Press Pack IGBT Considering the Application of Hybrid HVDC Breakers

被引:19
作者
Deng, Erping [1 ]
Wenzel, Oliver [1 ]
Zhao, Zhibin [1 ]
Zhang, Yiming [1 ]
Ying, Xiaoliang [1 ,2 ]
Li, Jinyuan [2 ]
Huang, Yongzhang [1 ]
机构
[1] North China Elect Power Univ, State Key Lab Alternate Elect Power Syst Renewabl, Beijing 102206, Peoples R China
[2] North China Elect Power Univ, State Grid Global Energy Interconnect Res Inst, Beijing 102211, Peoples R China
基金
中国国家自然科学基金;
关键词
Insulated gate bipolar transistors; HVDC transmission; Integrated circuit modeling; Fault currents; Solid modeling; Clamps; Couplings; Electro-thermo-mechanical model; field-circuit coupling model; hybrid high voltage direct current (HVdc) breakers; press pack insulated gate bipolar transistor (PP IGBT); MECHANICAL ANALYSIS;
D O I
10.1109/JESTPE.2020.3019433
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Press pack insulated gate bipolar transistor (PP IGBT) is suitable for the hybrid high voltage direct current (HVdc) breaker to clear the fault current of the flexible HVdc transmission system with its advantages of double-side cooling, short-circuit failure mode, and easy to connect in series. However, it should have the ability to transmit the fault current, which is up to five or six times of its rated current, within several milliseconds depending on the distances between two stations without external cooling system. The junction temperature of PP IGBT will increase sharply and it is not possible to be measured during that situation. Therefore, the accurate prediction of junction temperature is extremely important for the packaging design of PP IGBT according to its working condition. In this article, an electro-thermo-mechanical multiphysics field-circuit coupling model of PP IGBT, which is coupled with the electrical, thermal, and mechanical fields, is proposed to predict the collector current, clamping force, and junction temperature. The 3-D mechanical model is decoupled with the 1-D electro-thermal Cauer network model to simplify this multiphysics model without reducing its accuracy. Both the normal and worst working conditions are analyzed through this multiphysics field-circuit model.
引用
收藏
页码:4854 / 4864
页数:11
相关论文
共 26 条
[1]  
Backlund B, 2002, 5SYA203601 ABB 5SYA203601 ABB
[2]  
Bejan A., 2003, HEAT TRANSFER HDB
[3]  
Busca C, 2013, IEEE IND ELEC, P677, DOI 10.1109/IECON.2013.6699216
[4]  
Callavik M., 2012, Technical Paper, V361, P143
[5]   Power cycling on press-pack IGBTs: measurements and thermomechanical simulation [J].
Cova, P ;
Nicoletto, G ;
Pirondi, A ;
Portesine, M ;
Pasqualetti, M .
MICROELECTRONICS RELIABILITY, 1999, 39 (6-7) :1165-1170
[6]   COMPUTERIZED THERMAL-ANALYSIS OF HYBRID CIRCUITS [J].
DAVID, RF .
IEEE TRANSACTIONS ON PARTS HYBRIDS AND PACKAGING, 1977, 13 (03) :283-290
[7]  
Deng E, IN PRESS, V32, P201
[8]   Influence of Temperature on the Pressure Distribution Within Press Pack IGBTs [J].
Deng, Erping ;
Zhao, Zhibin ;
Lin, Zhongkang ;
Han, Ronggang ;
Huang, Yongzhang .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2018, 33 (07) :6048-6059
[9]   Optimization of the thermal contact resistance within press pack IGBTs [J].
Deng, Erping ;
Zhao, Zhibin ;
Zhang, Peng ;
Huang, Yongzhang ;
Li, Jinyuan .
MICROELECTRONICS RELIABILITY, 2017, 69 :17-28
[10]  
Guenin B. M, 2003, ELECT COOLING, V9, P10