Automatic detection on intracranial aneurysm from digital subtraction angiography with cascade convolutional neural networks

被引:32
|
作者
Duan, Haihan [1 ]
Huang, Yunzhi [2 ,3 ]
Liu, Lunxin [4 ]
Dai, Huming [1 ]
Chen, Liangyin [1 ,5 ]
Zhou, Liangxue [4 ,5 ]
机构
[1] Sichuan Univ, Coll Comp Sci, South Sect 1,Yihuan Rd, Chengdu 610065, Sichuan, Peoples R China
[2] Sichuan Univ, Coll Elect Engn, South Sect 1,Yihuan Rd, Chengdu 610065, Sichuan, Peoples R China
[3] Sichuan Univ, Coll Mat Sci & Engn, Dept Biomed Engn, South Sect 1,Yihuan Rd, Chengdu 610065, Sichuan, Peoples R China
[4] Sichuan Univ, West China Hosp, Dept Neurosurg, 37 Guo Xue Xiang, Chengdu 610041, Sichuan, Peoples R China
[5] Sichuan Univ, Inst Ind Internet Res, South Sect 1,Yihuan Rd, Chengdu 610065, Sichuan, Peoples R China
关键词
Intracranial aneurysm; Computer-aided diagnosis; Digital subtraction angiography; Object detection; Convolutional neural networks; CEREBRAL ANEURYSMS; MITOSIS DETECTION; CANCER;
D O I
10.1186/s12938-019-0726-2
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background An intracranial aneurysm is a cerebrovascular disorder that can result in various diseases. Clinically, diagnosis of an intracranial aneurysm utilizes digital subtraction angiography (DSA) modality as gold standard. The existing automatic computer-aided diagnosis (CAD) research studies with DSA modality were based on classical digital image processing (DIP) methods. However, the classical feature extraction methods were badly hampered by complex vascular distribution, and the sliding window methods were time-consuming during searching and feature extraction. Therefore, developing an accurate and efficient CAD method to detect intracranial aneurysms on DSA images is a meaningful task. Methods In this study, we proposed a two-stage convolutional neural network (CNN) architecture to automatically detect intracranial aneurysms on 2D-DSA images. In region localization stage (RLS), our detection system can locate a specific region to reduce the interference of the other regions. Then, in aneurysm detection stage (ADS), the detector could combine the information of frontal and lateral angiographic view to identify intracranial aneurysms, with a false-positive suppression algorithm. Results Our study was experimented on posterior communicating artery (PCoA) region of internal carotid artery (ICA). The data set contained 241 subjects for model training, and 40 prospectively collected subjects for testing. Compared with the classical DIP method which had an accuracy of 62.5% and an area under curve (AUC) of 0.69, the proposed architecture could achieve accuracy of 93.5% and the AUC of 0.942. In addition, the detection time cost of our method was about 0.569 s, which was one hundred times faster than the classical DIP method of 62.546 s. Conclusion The results illustrated that our proposed two-stage CNN-based architecture was more accurate and faster compared with the existing research studies of classical DIP methods. Overall, our study is a demonstration that it is feasible to assist physicians to detect intracranial aneurysm on DSA images using CNN.
引用
收藏
页数:18
相关论文
共 50 条
  • [41] ECHOCARDIOGRAPHY AND DIGITAL SUBTRACTION ANGIOGRAPHY IN DETECTION OF MYCOTIC FALSE ANEURYSM COMPLICATING COARCTATION OF THE AORTA
    DESA, EL
    GARCIAFERNANDEZ, F
    RAMOS, A
    SOTILLO, J
    VALENCIA, E
    KHAMASHTA, MA
    ARTERO, G
    AMERICAN HEART JOURNAL, 1988, 115 (04) : 898 - 900
  • [42] Deep learning based detection of intracranial aneurysms on digital subtraction angiography: A feasibility study
    Hainc, Nicolin
    Mannil, Manoj
    Anagnostakou, Vaia
    Alkadhi, Hatem
    Bluthgen, Christian
    Wacht, Lorenz
    Bink, Andrea
    Husain, Shakir
    Kulcsar, Zsolt
    Winklhofer, Sebastian
    NEURORADIOLOGY JOURNAL, 2020, 33 (04): : 311 - 317
  • [43] Convolutional neural network for automatic detection and characterization of abdominal aortic aneurysm
    Lareyre, Fabien
    Adam, Cedric
    Carrier, Marion
    Raffort, Juliette
    JOURNAL OF VASCULAR SURGERY CASES INNOVATIONS AND TECHNIQUES, 2023, 9 (01):
  • [44] Automatic detection of fatigue crack paths using digital image correlation and convolutional neural networks
    Strohmann, Tobias
    Starostin-Penner, Denis
    Breitbarth, Eric
    Requena, Guillermo
    FATIGUE & FRACTURE OF ENGINEERING MATERIALS & STRUCTURES, 2021, 44 (05) : 1336 - 1348
  • [45] Three-dimensional digital subtraction angiography vs two-dimensional digital subtraction angiography for detection of ruptured intracranial aneurysms:: a study of 86 aneurysms
    Kawashima, M
    Kitahara, T
    Soma, K
    Fujii, K
    NEUROLOGY INDIA, 2005, 53 (03) : 287 - 289
  • [46] TECHNIQUE FOR AUTOMATIC MOTION CORRECTION IN DIGITAL SUBTRACTION ANGIOGRAPHY
    FITZPATRICK, JM
    PICKENS, DR
    GREFENSTETTE, JJ
    PRICE, RR
    JAMES, AE
    OPTICAL ENGINEERING, 1987, 26 (11) : 1085 - 1093
  • [47] Three-dimensional computed tomographic angiography versus digital subtraction angiography in the detection of intracranial aneurysms in SAH
    Jethwa, P
    Sabit, A
    Russin, J
    Prestigiacomo, C
    JOURNAL OF NEUROSURGERY, 2006, 104 (04) : A644 - A644
  • [48] Computed Tomography Angiography Versus Digital Subtraction Angiography for Postclipping Aneurysm Obliteration Detection A Meta-Analysis
    Uricchio, Matthew
    Gupta, Saksham
    Jakowenko, Nicholas
    Levito, Marissa
    Nguyen Vu
    Doucette, Joanne
    Liew, Aaron
    Papatheodorou, Stefania
    Khawaja, Ayaz M.
    Aglio, Linda S.
    Aziz-Sultan, Mohammad Ali
    Zaidi, Hasan
    Smith, Timothy R.
    Mekary, Rania A.
    STROKE, 2019, 50 (02) : 381 - 388
  • [49] A comparative study of 64-channel multidetector CT angiography and digital subtraction angiography for the detection of intracranial aneurysms
    Xie, Peng
    Lu, Fajin
    Li, Qi
    Lao, Tianyou
    Li, Yongmei
    NEUROLOGY, 2008, 70 (11) : A462 - A462
  • [50] Bone subtraction CT angiography for the detection of intracranial aneurysms
    Ramasundara, S.
    Mitchell, P. J.
    Dowling, R. J.
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2010, 54 (06) : 526 - 533