Solid-state tris(2,2′-bipyridyl)ruthenium(II) electrogenerated chemiluminescence sensor based on ionic liquid/sol-gel titania/Nafion composite film

被引:13
作者
Jang, Junho [1 ]
Lee, Won-Yong [1 ]
机构
[1] Yonsei Univ, Dept Chem, Seoul 120749, South Korea
基金
新加坡国家研究基金会;
关键词
Chemiluminescence; ECL; Ionic liquid; Sol-gel titania; Composite film; DANSYL AMINO-ACIDS; MODIFIED ELECTRODE; BETA-BLOCKERS; ELECTROCHEMILUMINESCENCE; CHROMATOGRAPHY; NAFION; TRIS(2,2'-BIPYRIDINE)RUTHENIUM(II); TRIS(2,2-BIPYRIDYL)RUTHENIUM(II); ELECTROCHEMISTRY; RUTHENIUM;
D O I
10.1016/j.jelechem.2014.10.027
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The feasibility of being able to control the selectivity of solid-state tris(2,2'-bipyridyl)ruthenium(II) (Ru(bpy)(3)(2+)) electrogenerated chemiluminescence (ECL) sensor is proposed by selecting ionic liquids with appropriate hydrophobicity in the sol-gel titania/Nafion composite film. Four different kinds of ionic liquids with different hydrophobicity such as 1-butyl-3-methylimidazolium hexafluorophosphate (BMImPF(6)), 1-ethyl-3-methylimidazolium hexafluorophosphate (EMImPF(6)), 1-hexyl-3-methylimidazolium hexafluorophosphate (HMImPF(6)), 1-benzyl-3-methylimidazolium hexafluorophosphate (BnMImPF(6)) were incorporated in the sol-gel titania/Nafion composite films. The sequence of the observed ECL intensities for hydrophobic analytes is closely related to the sequence of the hydrophobicity of the ionic liquids used in the composite-based ECL sensor. In contrast, the observed ECL sequence for hydrophilic analytes such as ascorbic acid and oxalate is the opposite to the sequence of the hydrophobicity of the ionic liquids used in the composite film. Due to the decreased electron transfer resistance in the ionic liquid-based sol gel titania/Nafion composite films, the present ECL sensor based on the BMImPF(6)/titania/Nafion composite film gave a remarkable detection limit (S/N = 3) of 0.48 nM for TPA. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:55 / 60
页数:6
相关论文
共 57 条
[21]  
LEE WY, 1994, J CHROMATOGR A, V659, P111
[22]   EVALUATION OF USE OF TRIS(2,2'-BIPYRIDYL)RUTHENIUM(III) AS A CHEMILUMINESCENT REAGENT FOR QUANTITATION IN FLOWING STREAMS [J].
LEE, WY ;
NIEMAN, TA .
ANALYTICAL CHEMISTRY, 1995, 67 (11) :1789-1796
[23]   Tris (2,2'-bipyridyl)ruthenium(II) electrogenerated chemiluminescence in analytical science [J].
Lee, WY .
MIKROCHIMICA ACTA, 1997, 127 (1-2) :19-39
[24]   Ionic liquids as selectors for the enhanced detection of proteins [J].
Li, Tao ;
Li, Bingling ;
Dong, Shaojun ;
Wang, Erkang .
CHEMISTRY-A EUROPEAN JOURNAL, 2007, 13 (30) :8516-8521
[25]   Light emission from ruthenium-labeled penicillins signaling their hydrolysis by beta-lactamase [J].
Liang, P ;
Dong, LW ;
Martin, MT .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1996, 118 (38) :9198-9199
[26]   Electrochemiluminescence-based detection of beta-lactam antibiotics and beta-lactamases [J].
Liang, P ;
Sanchez, RI ;
Martin, MT .
ANALYTICAL CHEMISTRY, 1996, 68 (14) :2426-2431
[27]   An ionic liquid-type carbon paste polyoxometalate-modified electrode and its properties [J].
Liu, HT ;
He, P ;
Li, ZY ;
Sun, CY ;
Shi, LH ;
Liu, Y ;
Zhu, GY ;
Li, JH .
ELECTROCHEMISTRY COMMUNICATIONS, 2005, 7 (12) :1357-1363
[28]   Highly active horseradish peroxidase immobilized in 1-butyl-3-methylimidazolium tetrafluoroborate room-temperature ionic liquid based sol-gel host materials [J].
Liu, Y ;
Wang, MJ ;
Li, J ;
Li, ZY ;
He, P ;
Liu, HT ;
Li, JH .
CHEMICAL COMMUNICATIONS, 2005, (13) :1778-1780
[29]   GLUCOSE QUANTITATION USING AN IMMOBILIZED GLUCOSE-DEHYDROGENASE ENZYME REACTOR AND A TRIS(2,2'-BIPYRIDYL) RUTHENIUM(II) CHEMILUMINESCENT SENSOR [J].
MARTIN, AF ;
NIEMAN, TA .
ANALYTICA CHIMICA ACTA, 1993, 281 (03) :475-481
[30]   Chemiluminescence biosensors using tris(2,2'-bipyridyl)ruthenium(II) and dehydrogenases immobilized in cation exchange polymers [J].
Martin, AF ;
Nieman, TA .
BIOSENSORS & BIOELECTRONICS, 1997, 12 (06) :479-489