Lung Stereotactic Body Radiotherapy (SBRT) Using Spot-Scanning Proton Arc (SPArc) Therapy: A Feasibility Study

被引:24
|
作者
Liu, Gang [1 ,2 ]
Zhao, Lewei [2 ]
Qin, An [2 ]
Grills, Inga [2 ]
Deraniyagala, Rohan [2 ]
Stevens, Craig [2 ]
Zhang, Sheng [1 ]
Yan, Di [2 ]
Li, Xiaoqiang [2 ]
Ding, Xuanfeng [2 ]
机构
[1] Huazhong Univ Sci & Technol, Union Hosp, Tongji Med Coll, Canc Ctr, Wuhan, Peoples R China
[2] Beaumont Hlth Syst, Dept Radiat Oncol, Royal Oak, MI 48073 USA
来源
FRONTIERS IN ONCOLOGY | 2021年 / 11卷
关键词
lung; stereotactic body radiation therapy; spot-scanning; proton arc therapy; interplay effect; CANCER; IMPROVE;
D O I
10.3389/fonc.2021.664455
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose We developed a 4D interplay effect model to quantitatively evaluate breathing-induced interplay effects and assess the feasibility of utilizing spot-scanning proton arc (SPArc) therapy for hypo-fractionated lung stereotactic body radiotherapy (SBRT). The model was then validated by retrospective application to clinical cases. Materials and Methods A digital lung 4DCT phantoms was used to mimic targets in diameter of 3cm with breathing motion amplitudes: 5, 10, 15, and 20 mm, respectively. Two planning groups based on robust optimization were generated: (1) Two-field Intensity Modulated Proton Therapy (IMPT) plans and (2) SPArc plans via a partial arc. 5,000 cGy relative biological effectiveness (RBE) was prescribed to the internal target volume (ITV) in five fractions. To quantitatively assess the breathing induced interplay effect, the 4D dynamic dose was calculated by synchronizing the breathing pattern with the simulated proton machine delivery sequence, including IMPT, Volumetric repainting (IMPTvolumetric), iso-layered repainting (IMPTlayer) and SPArc. Ten lung patients' 4DCT previously treated with VMAT SBRT, were used to validate the digital lung tumor model. Normal tissue complicated probability (NTCP) of chestwall toxicity was calculated. Result Target dose were degraded as the tumor motion amplitude increased. The 4D interplay effect phantom model indicated that motion mitigation effectiveness using SPArc was about five times of IMPTvolumetric or IMPTlayer using maximum MU/spot as 0.5 MU at 20 mm motion amplitude. The retrospective study showed that SPArc has an advantage in normal tissue sparing. The probability of chestwall's toxicity were significantly improved from 40.2 +/- 29.0% (VMAT) (p = 0.01) and 16.3 +/- 12.0% (IMPT) (p = 0.01) to 10.1 +/- 5.4% (SPArc). SPArc could play a significant role in the interplay effect mitigation with breathing-induced motion more than 20 mm, where the target D99 of 4D dynamic dose for patient #10 was improved from 4,514 +/- 138 cGy [RBE] (IMPT) vs. 4,755 +/- 129 cGy [RBE] (SPArc) (p = 0.01). Conclusion SPArc effectively mitigated the interplay effect for proton lung SBRT compared to IMPT with repainting and was associated with normal tissue sparing. This technology may make delivery of proton SBRT more technically feasible and less complex with fewer concerns over underdosing the target compared to other proton therapy techniques.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Quantitative analysis of treatments using real-time image gated spot-scanning with synchrotron-based proton beam therapy system log data
    Yoshimura, Takaaki
    Shimizu, Shinichi
    Hashimoto, Takayuki
    Nishioka, Kentaro
    Katoh, Norio
    Taguchi, Hiroshi
    Yasuda, Koichi
    Matsuura, Taeko
    Takao, Seishin
    Tamura, Masaya
    Tanaka, Sodai
    Ito, Yoichi M.
    Matsuo, Yuto
    Tamura, Hiroshi
    Horita, Kenji
    Umegaki, Kikuo
    Shirato, Hiroki
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (12): : 10 - 19
  • [42] The evaluation of lung doses for radiation pneumonia risk in stereotactic body radiotherapy: A comparison of intensity modulated radiotherapy, intensity modulated arc therapy, cyberknife and helical tomotherapy
    Okutan, M.
    Franko, A.
    Koksal, C.
    Goksel, E. O.
    Karaman, S.
    Akpinar, Y. Emre
    Dagoglu, N.
    Demir, B.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2020, 18 (04): : 633 - 640
  • [43] Simulation study using the spots deletion technique in spot scanning proton beam therapy for prostate cancers
    Fukumitsu, Nobuyoshi
    Hayakawa, Tomokatsu
    Yamashita, Tomohiro
    Mima, Masayuki
    Demizu, Yusuke
    Suzuki, Takeshi
    Soejima, Toshinori
    MOLECULAR AND CLINICAL ONCOLOGY, 2022, 16 (01)
  • [44] Development and evaluation of a clinical model for lung cancer patients using stereotactic body radiotherapy (SBRT) within a knowledge-based algorithm for treatment planning
    Snyder, Karen Chin
    Kim, Jinkoo
    Reding, Anne
    Fraser, Corey
    Gordon, James
    Ajlouni, Munther
    Movsas, Benjamin
    Chetty, Indrin J.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (06): : 263 - 275
  • [45] Feasibility of postoperative spine stereotactic body radiation therapy in proximity of carbon and titanium hybrid implants using a robotic radiotherapy device
    Henzen, Dominik
    Schmidhalter, Daniel
    Guyer, Gian
    Stenger-Weisser, Anna
    Ermis, Ekin
    Poel, Robert
    Deml, Moritz Caspar
    Fix, Michael Karl
    Manser, Peter
    Aebersold, Daniel Matthias
    Hemmatazad, Hossein
    RADIATION ONCOLOGY, 2022, 17 (01)
  • [46] Stereotactic Body Radiotherapy: Volumetric Modulated Arc Therapy Versus 3D Non-coplanar Conformal Radiotherapy for the Treatment of Early Stage Lung Cancer
    Herbert, C.
    Kwa, W.
    Nakano, S.
    James, K.
    Moiseenko, V.
    Wu, J.
    Schellenberg, D.
    Liu, M.
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2013, 12 (06) : 511 - 516
  • [47] Flattening filter-free technique in volumetric modulated arc therapy for lung stereotactic body radiotherapy: A clinical comparison with the flattening filter technique
    Aoki, Shuri
    Yamashita, Hideomi
    Haga, Akihiro
    Nawa, Kanabu
    Imae, Toshikazu
    Takahashi, Wataru
    Abe, Osamu
    Nakagawa, Keiichi
    ONCOLOGY LETTERS, 2018, 15 (03) : 3928 - 3936
  • [48] Treatment plan comparison of volumetric-modulated arc therapy to intensity-modulated radiotherapy in lung stereotactic body radiotherapy using either 6-or 10-MV photon energies
    Wei, Zhigong
    Peng, Xingchen
    He, Ling
    Wang, Jingjing
    Liu, Zheran
    Xiao, Jianghong
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (08):
  • [49] Evaluation of the motion of lung tumors during stereotactic body radiation therapy (SBRT) with four-dimensional computed tomography (4DCT) using real-time tumor-tracking radiotherapy system (RTRT)
    Harada, Keiichi
    Katoh, Norio
    Suzuki, Ryusuke
    Ito, Yoichi M.
    Shimizu, Shinichi
    Onimaru, Rikiya
    Inoue, Tetsuya
    Miyamoto, Naoki
    Shirato, Hiroki
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (02): : 305 - 311
  • [50] Stereotactic body radiotherapy of central lung malignancies using asimultaneous integrated protection approach: Aprospective observational study
    Mazzola, Rosario
    Ruggieri, Ruggero
    Figlia, Vanessa
    Rigo, Michele
    Levra, Niccolo Giaj
    Ricchetti, Francesco
    Nicosia, Luca
    Corradini, Stefanie
    Alongi, Filippo
    STRAHLENTHERAPIE UND ONKOLOGIE, 2019, 195 (08) : 719 - 724