An investigation into the interaction of a XeCl excimer laser with hard tissue

被引:4
|
作者
Murray, AK [1 ]
Dickinson, MR [1 ]
机构
[1] Univ Manchester, Laser Photon Grp, Manchester M13 9PL, Lancs, England
关键词
ablation; dentine; laser-tissue interaction; UV; 308; nm;
D O I
10.1117/12.388039
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An investigation into the interaction of a fibre deliverable, long pulse, xenon chloride (308 nm) excimer laser with hard biotissue has been carried out. The laser produces pulses of 200+ ns as opposed to around 10-20 ns for most of the previously reported data(1,2) The threshold of ablation and the maximum ablation depth (AD) in human molar dentine were found to be 0.30+/-0.05 J/cm(2) and 1.57+/-0.04 mu m/pulse respectively. The threshold for enamel was found to be above the achievable fluence with the available optics. The ablation process was investigated as a function of fluence (similar to 0.1- 6 J/cm(2)), pulse repetition rate (PRR) (5-25 Hz) and number of pulses (500- 4000). Each variable was altered independently of the other two. At a constant number of pulses, ablation depth per pulse was found to increase linearly as a function of fluence, up to a saturation fluence of similar to 4 J/cm(2) Variation of the PRR alone was found to affect both the ablation threshold and the AD. For constant fluence and PRR, AD decreases non-linearly with an increasing number of pulses. This could be because at high pulse numbers the craters are deep, the walls of the crater absorb more energy and as it is increasingly difficult for the debris to escape, shielding of the tissue occurs. Shielding may also be due to absorption in a luminescent plume. At high fluence and PRR, sharp holes were formed in the dentine although charring was sometimes found around the edges. High PRR also induced considerable mechanical damage.
引用
收藏
页码:137 / 143
页数:7
相关论文
共 50 条
  • [1] ULTRAFAST IMAGING OF TISSUE ABLATION BY A XECL EXCIMER LASER IN SALINE
    PREISACK, MB
    NEU, W
    NYGA, R
    WEHRMANN, M
    HAASE, KK
    KARSCH, KR
    LASERS IN SURGERY AND MEDICINE, 1992, 12 (05) : 520 - 527
  • [2] XECL EXCIMER LASER INTERACTION WITH PARTIALLY-STABILIZED ZIRCONIA TARGET
    WONG, KH
    HAU, SK
    CHAN, PW
    LEUNG, LK
    CHOY, CL
    WONG, HK
    JOURNAL OF MATERIALS SCIENCE LETTERS, 1991, 10 (14) : 801 - 803
  • [3] A WIDELY TUNABLE XECL EXCIMER LASER
    CHALTAKOV, IV
    MINKOVSKI, NI
    TOMOV, IV
    OPTICS COMMUNICATIONS, 1988, 65 (06) : 437 - 439
  • [4] Stereolithography with XeCl excimer laser/lamp
    Satoh, S
    Tanaka, T
    Ihara, S
    Yamabe, C
    HIGH-POWER LASERS IN MANUFACTURING, 2000, 3888 : 264 - 271
  • [5] XECL EXCIMER LASER-INDUCED FLUORESCENCE FOR SELECTIVE ABLATION OF ATHEROMATOUS TISSUE
    ARAKAWA, K
    PAPAZOGLOU, T
    PAPAIOANNOU, T
    SHI, WQ
    FISHBEIN, M
    LITVACK, F
    FORRESTER, JS
    GRUNDFEST, WS
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1991, 55 (11): : 1094 - 1105
  • [6] Numerical investigation of generation of ultrashort pulses in a XeCl excimer laser with electrooptical deflector
    Badziak, J
    Jablonski, S
    OPTICA APPLICATA, 1997, 27 (01) : 55 - 68
  • [7] Beam divergence studies on hard edge unstable resonators for a long pulse XeCl excimer laser
    Hofstra, RM
    vanGoor, FA
    Witteman, WJ
    OPTICS COMMUNICATIONS, 1997, 144 (1-3) : 43 - 49
  • [8] ULTRAFINE STRUCTURE SPECTRUM OF XECL EXCIMER LASER
    LOU, QH
    HYPERFINE INTERACTIONS, 1987, 38 (1-4): : 531 - 537
  • [9] MUTAGENICITY AND THE XECL EXCIMER LASER - A RELATIONSHIP OF CONSEQUENCE
    FELD, MS
    KRAMER, JR
    AMERICAN HEART JOURNAL, 1991, 122 (06) : 1803 - 1805
  • [10] The Development and Progress of XeCl Excimer Laser System
    Zhang, Yongsheng
    Ma, Lianying
    Wang, Dahui
    Zhao, Xueqing
    Zhu, Yongxiang
    Hu, Yun
    Qian, Hang
    THIRD INTERNATIONAL SYMPOSIUM ON LASER INTERACTION WITH MATTER, 2015, 9543