We report a portable, all-solid-state, mid-infrared spectrometer for trace-gas analysis. The light source is a continuous-wave optical parametric oscillator based on PPLN and pumped by a Nd:YAG laser at 1064 nm. The generated single-frequency idler output covers the wavelength region between 2.35 and 3.75 mum. With its narrow line width, this light source is suitable for precise trace-gas analysis with very high sensitivity. Using cavity leak-out spectroscopy we achieved a minimum detectable absorption coefficient of 1.2 x 10(-9) /cm (integration time: 16 s), corresponding, for example, to a detection limit of 300 parts per trillion ethane. This sensitivity and the compact design make this trace-gas analyzer a promising tool for various in situ environmental and medical applications.
引用
收藏
页码:751 / 754
页数:4
相关论文
共 22 条
[1]   Laser intracavity absorption spectroscopy [J].
Baev, VM ;
Latz, T ;
Toschek, PE .
APPLIED PHYSICS B-LASERS AND OPTICS, 1999, 69 (03) :171-202
[2]   Continuous-wave singly resonant optical parametric oscillator based on periodically poled LiNbO3 [J].
Bosenberg, WR ;
Drobshoff, A ;
Alexander, JI ;
Myers, LE ;
Byer, RL .
OPTICS LETTERS, 1996, 21 (10) :713-715
[3]   Real-time monitoring of ethane in human breath using mid-infrared cavity leak-out spectroscopy [J].
Dahnke, H ;
Kleine, D ;
Hering, P ;
Mürtz, M .
APPLIED PHYSICS B-LASERS AND OPTICS, 2001, 72 (08) :971-975
[4]   Isotopic ratio measurement of methane in ambient air using mid-infrared cavity leak-out spectroscopy [J].
Dahnke, H ;
Kleine, D ;
Urban, C ;
Hering, P ;
Mürtz, M .
APPLIED PHYSICS B-LASERS AND OPTICS, 2001, 72 (01) :121-125
[5]   On-line monitoring of biogenic isoprene emissions using photoacoustic spectroscopy [J].
Dahnke, H ;
Kahl, J ;
Schüler, G ;
Boland, W ;
Urban, W ;
Kühnemann, F .
APPLIED PHYSICS B-LASERS AND OPTICS, 2000, 70 (02) :275-280
[6]   Fiber-laser-pumped continuous-wave singly resonant optical parametric oscillator [J].
Gross, P ;
Klein, ME ;
Walde, T ;
Boller, KJ ;
Auerbach, M ;
Wessels, P ;
Fallnich, C .
OPTICS LETTERS, 2002, 27 (06) :418-420
[7]   High-resolution Doppler-free molecular spectroscopy with a continuous-wave optical parametric oscillator [J].
Kovalchuk, EV ;
Dekorsy, D ;
Lvovsky, AI ;
Braxmaier, C ;
Mlynek, J ;
Peters, A ;
Schiller, S .
OPTICS LETTERS, 2001, 26 (18) :1430-1432
[8]   Photoacoustic trace-gas detection using a cw single-frequency parametric oscillator [J].
Kuhnemann, F ;
Schneider, K ;
Hecker, A ;
Martis, AAE ;
Urban, W ;
Schiller, S ;
Mlynek, J .
APPLIED PHYSICS B-LASERS AND OPTICS, 1998, 66 (06) :741-745
[9]   ASYMMETRIC RESPONSE PROFILE OF A SCANNING FABRY-PEROT-INTERFEROMETER [J].
LI, ZY ;
STEDMAN, GE ;
BILGER, HR .
OPTICS COMMUNICATIONS, 1993, 100 (1-4) :240-246
[10]   Tunable carbon monoxide overtone laser sideband system for precision spectroscopy from 2.6 to 4.1 μm [J].
Murtz, M ;
Frech, B ;
Palm, P ;
Lotze, R ;
Urban, W .
OPTICS LETTERS, 1998, 23 (01) :58-60