Flow injection determination methods of ascorbic acid

被引:71
作者
Yebra-Biurrun, MC [1 ]
机构
[1] Univ Santiago, Dept Analyt Chem Nutr & Bromatol, Fac Chem, Santiago De Compostela 15706, Spain
关键词
flow injection; ascorbic acid;
D O I
10.1016/S0039-9140(00)00402-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A review with 100 references is presented to show the advantages involved in the use of flow injection analysis (FIA) for the determination of ascorbic acid. The FI methods proposed for the determination of ascorbic acid are described and compared according to the used detection technique. Analytical figures of merit and interferences are also discussed. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:367 / 383
页数:17
相关论文
共 101 条
[1]   IODIMETRIC DETERMINATION OF IODATE, BROMATE, HYPOCHLORITE, ASCORBIC-ACID AND THIOUREA USING FLOW-INJECTION AMPEROMETRY [J].
ABDALLA, MA ;
ALSWAIDAN, HM .
ANALYST, 1989, 114 (05) :583-586
[2]   Direct chemiluminescence determination of ascorbic acid using flow injection analysis [J].
Agater, IB ;
Jewsbury, RA .
ANALYTICA CHIMICA ACTA, 1997, 356 (2-3) :289-294
[3]   DETERMINATION OF TITRATABLE ACIDITY AND ASCORBIC-ACID IN FRUIT JUICES IN CONTINUOUS-FLOW SYSTEMS [J].
ALAMO, JM ;
MAQUIEIRA, A ;
PUCHADES, R ;
SAGRADO, S .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 347 (6-7) :293-298
[4]   DETERMINATION OF ASCORBIC-ACID IN PHARMACEUTICALS AND URINE BY REVERSE FLOW-INJECTION [J].
ALBERO, MI ;
GARCIA, MS ;
SANCHEZPEDRENO, C ;
RODRIGUEZ, J .
ANALYST, 1992, 117 (10) :1635-1638
[5]   INDIVIDUAL AND SIMULTANEOUS DETERMINATION OF URIC-ACID AND ASCORBIC-ACID BY FLOW-INJECTION ANALYSIS [J].
ALMUAIBED, AM ;
TOWNSHEND, A .
TALANTA, 1992, 39 (11) :1459-1462
[6]   DETERMINATION OF ASCORBIC-ACID BY FLOW-INJECTION WITH CHEMILUMINESCENCE DETECTION [J].
ALWARTHAN, AA .
ANALYST, 1993, 118 (06) :639-642
[7]   MULTICHANNEL ELECTROCHEMICAL DETECTION WITH A MICROELECTRODE ARRAY IN FLOWING STREAMS [J].
AOKI, A ;
MATSUE, T ;
UCHIDA, I .
ANALYTICAL CHEMISTRY, 1992, 64 (01) :44-49
[8]   ELECTROCHEMISTRY AND DETECTION OF SOME ORGANIC AND BIOLOGICAL MOLECULES AT CONDUCTING POLY(3-METHYLTHIOPHENE) ELECTRODES [J].
ATTA, NF ;
GALAL, A ;
KARAGOZLER, AE ;
RUSSELL, GC ;
ZIMMER, H ;
MARK, HB .
BIOSENSORS & BIOELECTRONICS, 1991, 6 (04) :333-341
[9]   Nickel (II) tetraaza macrocycle modified electrodes for the electrocatalytic determination of L-ascorbic acid by the flow injection method [J].
Bae, ZU ;
Park, JH ;
Lee, SH ;
Chang, HY .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1999, 468 (01) :85-90
[10]   FLOW-INJECTION ANALYSIS WITH AN ENZYME REACTOR BED FOR DETERMINATION OF ASCORBIC-ACID IN BRAIN-TISSUE [J].
BRADBERRY, CW ;
ADAMS, RN .
ANALYTICAL CHEMISTRY, 1983, 55 (14) :2439-2440