Application of Numerical Simulation Technology In the large Space Air-conditioned Buildings Air-conditioned Buildings

被引:0
|
作者
Li Jianwei [1 ]
Feng Zengxi [1 ]
机构
[1] Xian Univ Architecture & Technol, Xian, Peoples R China
来源
ADVANCED DEVELOPMENT IN AUTOMATION, MATERIALS AND MANUFACTURING | 2014年 / 624卷
关键词
Large space air-conditioned buildings; air-conditioned buildings; Numerical simulation; Indoor thermal environment; Similarity theory;
D O I
10.4028/www.scientific.net/AMM.624.657
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper takes the large space air-conditioned buildings air-conditioned buildings as research subjects and sets numerical conditions of large space air-conditioned buildings prototype to conduct a simulation study by means of numerical simulation. Numerical and experimental results show that the standard k-epsilon turbulence model can be used to describe the characteristics of the large space air-conditioned buildings building; the experimental results of a typical location room temperature basically consistent with the numerical results of the prototype and enlarged model. Results of this study will provide a useful reference for the researches of large space air-conditioned buildings air-conditioned building.
引用
收藏
页码:657 / 660
页数:4
相关论文
共 50 条
  • [31] Daily energy consumption signatures and control charts for air-conditioned buildings
    Hitchin, Roger
    Knight, Ian
    ENERGY AND BUILDINGS, 2016, 112 : 101 - 109
  • [32] Numerical simulation to air distribution in air-conditioned hard sleeper compartment
    Zhang, Dengchun
    Zou, Shenghua
    Weng, Peifen
    Yingyong Lixue Xuebao/Chinese Journal of Applied Mechanics, 2006, 23 (01): : 132 - 136
  • [33] Thermal Adaptive Behavior of Occupants in Air-conditioned Office Buildings in Thailand
    Sikram, Tanadej
    Ichinose, Masayuki
    Sasaki, Rumiko
    SUSTAINABLE BUILT ENVIRONMENT CONFERENCE 2019 TOKYO (SBE19TOKYO) - BUILT ENVIRONMENT IN AN ERA OF CLIMATE CHANGE: HOW CAN CITIES AND BUILDINGS ADAPT?, 2019, 294
  • [34] Calculation models and frequency analysis of moisture transfer in air-conditioned buildings
    Chen, YM
    Wang, SW
    ISHVAC 99: 3RD INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, VOLS 1 AND 2, 1999, : 1050 - 1058
  • [35] Building energy performance of air-conditioned office buildings in Hong Kong
    Chan, RYC
    Lam, JC
    Li, DHW
    Tsang, EKW
    PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY, VENTILATION AND ENERGY CONSERVATION IN BUILDINGS, VOLS I-III, 2001, : 985 - 992
  • [36] Assessment of productivity loss in air-conditioned buildings using PMV index
    Kosonen, R
    Tan, F
    ENERGY AND BUILDINGS, 2004, 36 (10) : 987 - 993
  • [37] The Influence of Glass Types on the Performance of Air-Conditioned Office Buildings in Australia
    Guan, Lisa
    SUSTAINABLE CONSTRUCTION MATERIALS AND COMPUTER ENGINEERING, 2012, 346 : 34 - 39
  • [38] Ventilation of air-conditioned residential buildings: A case study in Hong Kong
    Z.T.Ai
    C.M.Mak
    D.J.Cui
    P.Xue
    侯恩哲
    建筑节能, 2016, 44 (09) : 5 - 5
  • [39] Ventilation of air-conditioned residential buildings: A case study in Hong Kong
    Ai, Z. T.
    Mak, C. M.
    Cui, D. J.
    Xue, P.
    ENERGY AND BUILDINGS, 2016, 127 : 116 - 127
  • [40] A Numerical Study of the Indoor Thermal Environment in an Air-conditioned Large Space Building
    Liu Jiying
    PROCEEDINGS OF 8TH INTERNATIONAL CONFERENCE ON INTELLIGENT COMPUTATION TECHNOLOGY AND AUTOMATION (ICICTA 2015), 2015, : 69 - 72