Speed-of-sound imaging in a photoacoustic imager

被引:1
作者
Manohar, Srirang [1 ]
Willemink, Rene G. H. [2 ]
van Leeuwen, Ton G. [1 ]
机构
[1] Univ Twente, Inst Biomed Technol, Biophys Engn Grp, Fac Appl Phys, Postbox 217, NL-7500 AE Enschede, Netherlands
[2] Univ Twente, Inst Biomed Technol BMTI, Signals & Syst Grp SaS, Fac Elect Engn EWI, NL-7500 AE Enschede, Netherlands
来源
PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2007 | 2007年 / 6437卷
关键词
D O I
10.1117/12.700078
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The effects of an inappropriately chosen speed-of-sound in photoacoustic imaging reconstructions are to cause blurring of images and impairment of contrast. Here we outline a new methodology to measure the speed-of-sound in a photoacoustic imager with little or no additional cost and without the need to perform extra measurements. The method uses a strong absorber of light which is placed in the path of the light illuminating the sample. This acts as a source of ultrasound whose interaction with the sample can be measured at the far-end of the sample using the same ultrasound detector used for photoacoustics. This yields time-of-arrival measurements of the ultrasound transient at the multi-element detector. Such measurements are made at various angles around the sample in a computerized tomography approach. Reconstruction of the time-of-arrival or speed-of-sound tomogram of the object can be made by implementing a fan-beam projection reconstruction algorithm. We present the concept and validate the method on a speed-of-sound phantom.
引用
收藏
页数:8
相关论文
共 17 条
[1]  
Bamber J.C., 1997, ENCY ACOUSTICS, V4, P1703
[2]   Image reconstruction for photoacoustic scanning of tissue structures [J].
Hoelen, CGA ;
de Mul, FFM .
APPLIED OPTICS, 2000, 39 (31) :5872-5883
[3]   Thermoacoustic tomography with correction for acoustic speed variations [J].
Jin, Xing ;
Wang, Lihong V. .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (24) :6437-6448
[4]  
Kak A.C. Slaney M., 1999, PRINCIPLES COMPUTERI
[5]   In vivo photoacoustic imaging of blood vessels using an extreme-narrow aperture sensor [J].
Kolkman, RGM ;
Hondebrink, E ;
Steenbergen, W ;
de Mul, FFM .
IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 2003, 9 (02) :343-346
[6]  
KOLKMAN RGM, 2007, IN PRESS OPT EXPRESS
[7]   Thermoacoustic CT of the breast [J].
Kruger, RA ;
Stantz, K ;
Kiser, WL .
MEDICAL IMAGING 2002: PHYSICS OF MEDICAL IMAGING, 2002, 4682 :521-525
[8]   Thermoacoustic CT scanner for breast imaging: Design considerations [J].
Kruger, RA ;
Kiser, WL ;
Miller, KD ;
Reynolds, HE ;
Reinecke, DR ;
Kruger, GA ;
Hofacker, PJ ;
Eisenhart, RL .
MEDICAL IMAGING 2000: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2000, 3982 :354-359
[9]   Thermoacoustic molecular imaging of small animals [J].
Kruger, Robert A. ;
Kiser, William L. ;
Reinecke, Daniel R. ;
Kruger, Gabe A. ;
Miller, Kathy D. .
Molecular Imaging, 2003, 2 (02) :113-123
[10]   The Twente Photoacoustic Mammoscope: system overview and performance [J].
Manohar, S ;
Kharine, A ;
van Hespen, JCG ;
Steenbergen, W ;
van Leeuwen, TG .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (11) :2543-2557