Metal Ion Levels and Functional Results Following Resurfacing Hip Arthroplasty Versus Conventional Small-Diameter Metal-on-Metal Total Hip Arthroplasty, a 3 to 5 year Follow-Up of a Randomized Controlled Trial

被引:28
作者
Bisseling, Pepijn [1 ]
Smolders, Jose M. H. [1 ]
Hol, Annemiek [1 ]
van Susante, Job L. C. [1 ]
机构
[1] Ziekenhuis Rijnstate, Dept Orthopaed, NL-6800 TA Arnhem, Netherlands
关键词
total hip arthroplasty; resurfacing hip arthroplasty; metal-on-metal bearing; metal ions; cobalt; chromium; PROSPECTIVE COHORT; SERUM COBALT; REPLACEMENT; PSEUDOTUMOR; PREVALENCE; DEBRIS; BLOOD;
D O I
10.1016/j.arth.2014.07.036
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We present an update of a randomized controlled trial on 71 patients (<65 years) who received either a resurfacing hip arthroplasty (RHA) (n = 38) or cementless 28 mm metal-on-metal (MOM) total hip arthroplasty (THA) (n = 33). Metal ion levels and functional outcome scores were analyzed with a mean follow-up of 58 months (SD 8.1). No clear shifts in relatively good outcome was encountered between RHA and THA. Metal ion levels appear to equalize between groups after 3 years. Median cobalt and chromium remained below 1.3 mu g/L throughout follow-up in both groups. Six revisions were performed, of which three for pseudotumor formation (one THA, two RHA). In conclusion there were no clinical differences between the two groups and metal ion levels were lower than other series remained low, however, pseudotumor formation was not eliminated. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:61 / 67
页数:7
相关论文
共 38 条
  • [1] Allan D Gordon, 2007, J Surg Orthop Adv, V16, P12
  • [2] Resurfacing THA for patients younger than 50 years - Results of 2- to 9-year followup
    Amstutz, Harlan C.
    Ball, Scott T.
    Le Duff, Michel J.
    Dorey, Frederick J.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (460) : 159 - 164
  • [3] Metal-on-metal hybrid surface arthroplasty:: Two to six-year follow-up study
    Amstutz, HC
    Beaulé, PE
    Dorey, FJ
    Le Duff, MJ
    Campbell, PA
    Gruen, TA
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (01) : 28 - 39
  • [4] [Anonymous], MED DEV AL ALL MET O
  • [5] How do serum cobalt and chromium levels change after metal-on-metal hip resurfacing?
    Back, DL
    Young, AA
    Shimmin, AJ
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (438) : 177 - 181
  • [6] High Prevalence of Pseudotumors in Patients with a Birmingham Hip Resurfacing Prosthesis A Prospective Cohort Study of One Hundred and Twenty-nine Patients
    Bisschop, R.
    Boomsma, M. F.
    Van Raay, J. J. A. M.
    Tiebosch, A. T. M. G.
    Maas, M.
    Gerritsma, C. L. E.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2013, 95A (17) : 1554 - 1560
  • [7] Bisseling P, 2011, ACTA ORTHOP, V82, P161, DOI [10.3109/17453674.2011.566140, 10.3109/17453674.2011.625533]
  • [8] High incidence of pseudotumour formation after large-diameter metal-on-metal total hip replacement A PROSPECTIVE COHORT STUDY
    Bosker, B. H.
    Ettema, H. B.
    Boomsma, M. F.
    Kollen, B. J.
    Maas, M.
    Verheyen, C. C. P. M.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2012, 94B (06): : 755 - 761
  • [9] Serum cobalt levels after metal-on-metal total hip arthroplasty
    Brodner, W
    Bitzan, P
    Meisinger, V
    Kaider, A
    Gottsauner-Wolf, F
    Kotz, R
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (11) : 2168 - 2173
  • [10] Birmingham hip resurfacing at a mean of ten years RESULTS FROM AN INDEPENDENT CENTRE
    Coulter, G.
    Young, D. A.
    Dalziel, R. E.
    Shimmin, A. J.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2012, 94B (03): : 315 - 321