Skin Pigmentation Influence on Pulse Oximetry Accuracy: A Systematic Review and Bibliometric Analysis

被引:64
|
作者
Cabanas, Ana M. [1 ]
Fuentes-Guajardo, Macarena [2 ]
Latorre, Katina [2 ]
Leon, Dayneri [3 ]
Martin-Escudero, Pilar [4 ]
机构
[1] Univ Tarapaca, Dept Fis, Arica 1010069, Chile
[2] Univ Tarapaca, Dept Tecnol Med, Arica 1010069, Chile
[3] Univ Tarapaca, Dept Educ Fis, Arica 1010069, Chile
[4] Univ Complutense Madrid, Fac Med, Med Sch Sport Med, Madrid 28040, Spain
关键词
pulse oximetry; oxygen saturation; skin pigmentation; accuracy; photoplethysmography; OXYGEN-SATURATION; REMOTE-PPG; PHOTOPLETHYSMOGRAPHY; HEMOGLOBIN; RELIABILITY; INACCURACY; EXERCISE; OUTCOMES; INFANTS; ERRORS;
D O I
10.3390/s22093402
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Nowadays, pulse oximetry has become the standard in primary and intensive care units, especially as a triage tool during the current COVID-19 pandemic. Hence, a deeper understanding of the measurement errors that can affect precise readings is a key element in clinical decision-making. Several factors may influence the accuracy of pulse oximetry, such as skin color, body temperature, altitude, or patient movement. The skin pigmentation effect on pulse oximetry accuracy has long been studied reporting some contradictory conclusions. Recent studies have shown a positive bias in oxygen saturation measurements in patients with darkly pigmented skin, particularly under low saturation conditions. This review aims to study the literature that assesses the influence of skin pigmentation on the accuracy of these devices. We employed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement to conduct a systematic review retrospectively since February 2022 using WOS, PubMed, and Scopus databases. We found 99 unique references, of which only 41 satisfied the established inclusion criteria. A bibliometric and scientometrics approach was performed to examine the outcomes of an exhaustive survey of the thematic content and trending topics.
引用
收藏
页数:20
相关论文
共 50 条
  • [1] The accuracy of pulse oximetry in measuring oxygen saturation by levels of skin pigmentation: a systematic review and meta-analysis
    Shi, Chunhu
    Goodall, Mark
    Dumville, Jo
    Hill, James
    Norman, Gill
    Hamer, Oliver
    Clegg, Andrew
    Watkins, Caroline Leigh
    Georgiou, George
    Hodkinson, Alexander
    Lightbody, Catherine Elizabeth
    Dark, Paul
    Cullum, Nicky
    BMC MEDICINE, 2022, 20 (01)
  • [2] The accuracy of pulse oximetry in measuring oxygen saturation by levels of skin pigmentation: a systematic review and meta-analysis
    Chunhu Shi
    Mark Goodall
    Jo Dumville
    James Hill
    Gill Norman
    Oliver Hamer
    Andrew Clegg
    Caroline Leigh Watkins
    George Georgiou
    Alexander Hodkinson
    Catherine Elizabeth Lightbody
    Paul Dark
    Nicky Cullum
    BMC Medicine, 20
  • [3] Impact of Skin Pigmentation on Pulse Oximetry Blood Oxygenation and Wearable Pulse Rate Accuracy: Systematic Review and Meta-Analysis
    Singh, Sanidhya
    Bennett, Miles Romney
    Chen, Chen
    Shin, Sooyoon
    Ghanbari, Hamid
    Nelson, Benjamin W.
    JOURNAL OF MEDICAL INTERNET RESEARCH, 2024, 26
  • [4] Effect of skin pigmentation on pulse oximetry accuracy in the emergency department
    Adler, JN
    Hughes, LA
    Vivilecchia, R
    Camargo, CA
    ACADEMIC EMERGENCY MEDICINE, 1998, 5 (10) : 965 - 970
  • [5] The Effect of Skin Pigmentation on the Accuracy of Pulse Oximetry in Infants with Hypoxemia
    Foglia, Elizabeth E.
    Whyte, Robin K.
    Chaudhary, Aasma
    Mott, Antonio
    Chen, Jodi
    Propert, Kathleen J.
    Schmidt, Barbara
    JOURNAL OF PEDIATRICS, 2017, 182 : 375 - 377
  • [6] Skin Pigmentation Effects on Pulse Oximetry Accuracy Need a Prospective Study
    Blike, George T.
    McGrath, Susan P.
    McGovern, Krystal
    JOURNAL OF PATIENT SAFETY, 2023, 19 (04) : 221 - 222
  • [7] A review of the effect of skin pigmentation on pulse oximeter accuracy
    Al-Halawani, Raghda
    Charlton, Peter H.
    Qassem, Meha
    Kyriacou, Panayiotis A.
    PHYSIOLOGICAL MEASUREMENT, 2023, 44 (05)
  • [8] Effect of skin tone on the accuracy of the estimation of arterial oxygen saturation by pulse oximetry: a systematic review
    Martin, Daniel
    Johns, Chris
    Sorrell, Lexy
    Healy, Eugene
    Phull, Mandeep
    Olusanya, Segun
    Peters, Mark
    Fabes, Jeremy
    BRITISH JOURNAL OF ANAESTHESIA, 2024, 132 (05) : 945 - 956
  • [9] Accuracy of Pulse Oximetry in the Presence of Fetal Hemoglobin-A Systematic Review
    Pritisanac, Ena
    Urlesberger, Berndt
    Schwaberger, Bernhard
    Pichler, Gerhard
    CHILDREN-BASEL, 2021, 8 (05):
  • [10] Melanometry for objective evaluation of skin pigmentation in pulse oximetry studies
    Vasudevan, Sandhya
    Vogt, William C.
    Weininger, Sandy
    Pfefer, T. Joshua
    COMMUNICATIONS MEDICINE, 2024, 4 (01):