Effect of variable light intensity on composite shrinkage

被引:57
作者
Dennison, JB [1 ]
Yaman, P [1 ]
Seir, R [1 ]
Hamilton, JC [1 ]
机构
[1] Univ Michigan, Sch Dent, Dept Cariol Restorat Sci & Endodont, Ann Arbor, MI 48109 USA
关键词
D O I
10.1067/mpr.2000.110494
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Polymerization shrinkage is a critical limitation of dental composites and may contribute to postoperative pain, tooth fracture, microleakage, and secondary caries. Polymerization with high-intensity light sources has been related to increased depth of cure and improved mechanical properties. However, high intensity light initiation has also been associated with greater polymerization shrinkage. Purpose. The purpose of this study was to investigate the effect of sequentially increasing light intensity on the polymerization shrinkage of 2 composites, a hybrid and a microfil. A Knoop hardness test was used to evaluate effectiveness of the cure with each intensity increase. Material and methods. Four groups of 12 samples were measured for polymerization shrinkage by using a linometer. Light intensity curing sequences were as follows: full-intensity control (100% intensity for 40 seconds), low-intensity control (25% intensity for 40 seconds), test group 1 (25% intensity for 20 seconds, 50% for 10 seconds, 100% for 10 seconds), and test group 2 (25% intensity for 10 seconds, 50% for 10 seconds, 100% for 20 seconds). Statistical comparisons were made using a 1-factor ANOVA and a Tukey multiple comparisons test within each material. Results. Results showed a significant difference (P<.05) in mean linear shrinkage between the full-intensity control group and the other 3 sequences for both composites. No difference existed within the other 3 groups for either composite. Knoop hardness was similar for the full-intensity control and test group 2. The low-intensity control group and test group 1 were also similar but significantly lower. Conclusion. Curing composites for 10 seconds at 25% intensity, 10 seconds at 50%, and 20 seconds at 100% significantly reduced polymerization shrinkage while not compromising depth of cure.
引用
收藏
页码:499 / 505
页数:7
相关论文
共 22 条
[1]   THE DEPENDENCE OF SHRINKAGE STRESS REDUCTION ON POROSITY CONCENTRATION IN THIN RESIN LAYERS [J].
ALSTER, D ;
FEILZER, AJ ;
DEGEE, AJ ;
MOL, A ;
DAVIDSON, CL .
JOURNAL OF DENTAL RESEARCH, 1992, 71 (09) :1619-1622
[2]  
[Anonymous], 1991, DENT MATER
[3]   COMPOSITE RESTORATIVE RESINS - COMPOSITION VERSUS WALL-TO-WALL POLYMERIZATION CONTRACTION [J].
ASMUSSEN, E .
ACTA ODONTOLOGICA SCANDINAVICA, 1975, 33 (06) :337-344
[4]  
BAUSCH JR, 1982, J PROSTHET DENT, V48, P59, DOI 10.1016/0022-3913(82)90048-8
[5]  
Bertolotti R L, 1991, Pract Periodontics Aesthet Dent, V3, P53
[6]   TRUE LINEAR POLYMERIZATION SHRINKAGE OF UNFILLED RESINS AND COMPOSITES DETERMINED WITH A LINOMETER [J].
DEGEE, AJ ;
FEILZER, AJ ;
DAVIDSON, CL .
DENTAL MATERIALS, 1993, 9 (01) :11-14
[7]  
Eick J D, 1986, Quintessence Int, V17, P103
[8]   ALTERNATIVE INTERPRETATIONS OF WATER SORPTION VALUES OF COMPOSITE RESINS [J].
FAN, PL ;
EDAHL, A ;
LEUNG, RL ;
STANFORD, JW .
JOURNAL OF DENTAL RESEARCH, 1985, 64 (01) :78-80
[9]   SETTING STRESS IN COMPOSITE RESIN IN RELATION TO CONFIGURATION OF THE RESTORATION [J].
FEILZER, AJ ;
DEGEE, AJ ;
DAVIDSON, CL .
JOURNAL OF DENTAL RESEARCH, 1987, 66 (11) :1636-1639
[10]   INFLUENCE OF LIGHT-INTENSITY ON POLYMERIZATION SHRINKAGE AND INTEGRITY OF RESTORATION-CAVITY INTERFACE [J].
FEILZER, AJ ;
DOOREN, LH ;
DEGEE, AJ ;
DAVIDSON, CL .
EUROPEAN JOURNAL OF ORAL SCIENCES, 1995, 103 (05) :322-326