Regularized reconstruction in quantitative SPECT using CT side information from hybrid imaging

被引:30
作者
Dewaraja, Yuni K. [1 ]
Koral, Kenneth F. [1 ]
Fessler, Jeffrey A. [1 ,2 ]
机构
[1] Univ Michigan, Dept Radiol, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Elect Engn & Comp Sci, Ann Arbor, MI 48109 USA
基金
美国国家卫生研究院;
关键词
EMISSION TOMOGRAPHY; BAYESIAN RECONSTRUCTION; DOSIMETRY; PATIENT; IMPLEMENTATION; COMPENSATION; ALGORITHMS; THERAPY;
D O I
10.1088/0031-9155/55/9/007
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A penalized-likelihood (PL) SPECT reconstruction method using a modified regularizer that accounts for anatomical boundary side information was implemented to achieve accurate estimates of both the total target activity and the activity distribution within targets. In both simulations and experimental I-131 phantom studies, reconstructions from ( 1) penalized likelihood employing CT-side information-based regularization (PL-CT), ( 2) penalized likelihood with edge preserving regularization (no CT) and ( 3) penalized likelihood with conventional spatially invariant quadratic regularization ( no CT) were compared with ( 4) ordered subset expectation maximization (OSEM), which is the iterative algorithm conventionally used in clinics for quantitative SPECT. Evaluations included phantom studies with perfect and imperfect side information and studies with uniform and non-uniform activity distributions in the target. For targets with uniform activity, the PL-CT images and profiles were closest to the 'truth', avoided the edge offshoots evident with OSEM and minimized the blurring across boundaries evident with regularization without CT information. Apart from visual comparison, reconstruction accuracy was evaluated using the bias and standard deviation ( STD) of the total target activity estimate and the root mean square error (RMSE) of the activity distribution within the target. PL-CT reconstruction reduced both bias and RMSE compared with regularization without side information. When compared with unregularized OSEM, PL-CT reduced RMSE and STD while bias was comparable. For targets with non-uniform activity, these improvements with PL-CT were observed only when the change in activity was matched by a change in the anatomical image and the corresponding inner boundary was also used to control the regularization. In summary, the present work demonstrates the potential of using CT side information to obtain improved estimates of the activity distribution in targets without sacrificing the accuracy of total target activity estimation. The method is best suited for data acquired on hybrid systems where SPECT-CT misregistration is minimized. To demonstrate clinical application, the PL reconstruction with CT-based regularization was applied to data from a patient who underwent SPECT/CT imaging for tumor dosimetry following I-131 radioimmunotherapy.
引用
收藏
页码:2523 / 2539
页数:17
相关论文
共 27 条
[1]   Methodology to Incorporate Biologically Effective Dose and Equivalent Uniform Dose in Patient-Specific 3-Dimensional Dosimetry for Non-Hodgkin Lymphoma Patients Targeted with 131I-Tositumomab Therapy [J].
Amro, Hanan ;
Wilderman, Scott J. ;
Dewaraja, Yuni K. ;
Roberson, Peter L. .
JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (04) :654-659
[2]   Study of relative quantification of Tc-99 m with partial volume effect and spillover correction for SPECT oncology imaging [J].
Boening, Guido ;
Pretorius, P. Hendrik ;
King, Michael A. .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (03) :1205-1212
[3]   Bayesian reconstruction and use of anatomical a Priori information for emission tomography [J].
Bowsher, JE ;
Johnson, VE ;
Turkington, TG ;
Jaszczak, RJ ;
Floyd, CE ;
Coleman, RE .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1996, 15 (05) :673-686
[4]   Clinically feasible reconstruction of 3D whole-body PET/CT data using blurred anatomical labels [J].
Comtat, C ;
Kinahan, PE ;
Fessler, JA ;
Beyer, T ;
Townsend, DW ;
Defrise, M ;
Michel, C .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (01) :1-20
[5]  
Dewaraja YK, 2005, J NUCL MED, V46, P840
[6]  
DEWARAJA YK, 2006, J NUCL MED, V47, pP115
[7]   Use of Integrated SPECT/CT Imaging for Tumor Dosimetry in I-131 Radioimmunotherapy: A Pilot Patient Study [J].
Dewaraja, Yuni K. ;
Wilderman, Scott J. ;
Koral, Kenneth F. ;
Kaminski, Mark S. ;
Avram, Anca M. .
CANCER BIOTHERAPY AND RADIOPHARMACEUTICALS, 2009, 24 (04) :417-426
[8]   Partial volume effect compensation for quantitative brain SPECT imaging [J].
Du, Y ;
Tsui, BMW ;
Frey, EC .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2005, 24 (08) :969-976
[9]   Ordered subsets algorithms for transmission tomography [J].
Erdogan, H ;
Fessler, JA .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (11) :2835-2851
[10]   REGULARIZED EMISSION IMAGE-RECONSTRUCTION USING IMPERFECT SIDE INFORMATION [J].
FESSLER, JA ;
CLINTHORNE, NH ;
ROGERS, WL .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1992, 39 (05) :1464-1471