New quantitative image analysis of staphylococcal biofilms on the surfaces of nontranslucent metallic biomaterials

被引:18
作者
Adachi, Kouichi
Tsurumoto, Toshiyuki
Yonekura, Akihiko
Nishimura, Seisuke
Kajiyama, Shiro
Hirakata, Yoichi
Shindo, Hiroyuki
机构
[1] Nagasaki Univ, Grad Sch Biomed Sci, Dept Orthopaed Surg, Nagasaki 8528501, Japan
[2] Nagasaki Univ, Grad Sch Biomed Sci, Dept Internal Med 2, Nagasaki 852, Japan
关键词
D O I
10.1007/s00776-006-1102-1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background. Implant-related infection after orthopedic surgery is difficult to cure. One of the causes of infection is the bacterial biofilm that forms around biomaterials used during surgery. Therefore, it is necessary to investigate bacterial biofilms extensively to resolve the problems of these postoperative infections. However, no established culture method or quantification system exists for bacterial biofilms grown on the surface of the metallic biomaterials used in orthopedics, which are nonradiolucent. The purpose of this study was to develop a quantitative method to evaluate the difference in resistance of stainless steel versus titanium to staphylococcal biofilms and the efficacy of antibiotics against biofilms. Methods. The bacterial strains used in this study were three Staphylococcus aureus stains: strain Seattle 1945 and two clinical strains cultured from postoperative infections. Staphylococcal biofilms were formed on stainless steel washers (SUS304) and titanium washers (pure titanium). They were stained with crystal violet and were examined with a digital microscope to calculate the bacterial coverage rate (BCR) by NIH imaging. Results. The BCR of S. aureus biofilms formed on stainless steel and titanium washers increased over time. At 24, 48, and 72 h after cultivation, the amount of biofilm on the surface of the stainless steel washers was significantly greater or tended to be greater than that on the titanium. Cefazolin was applied to the obtained biofilms of two clinically isolated S. aureus strains. Cefazolin did not eradicate the biofilms but significantly reduced the biofilm of one strain. Conclusion. The newly developed quantitative method (static microtube culture and measurement system) was useful for assessing the amount of bacterial biofilms on the surface of nontranslucent biomaterial. We found that titanium may be more resistant to bacterial infection than stainless steel. To control implant-related severe infections, the biomaterials should be assessed from the viewpoint of their resistibility to bacterial adhesions and infections.
引用
收藏
页码:178 / 184
页数:7
相关论文
共 18 条
[1]   Antibiotic susceptibility assay for Staphylococcus aureus in biofilms developed in vitro [J].
Amorena, B ;
Gracia, E ;
Monzón, M ;
Leiva, J ;
Oteiza, C ;
Pérez, M ;
Alabart, JL ;
Hernández-Yago, J .
JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 1999, 44 (01) :43-55
[2]   Laboratory methods for studies of bacterial adhesion [J].
An, YH ;
Friedman, RJ .
JOURNAL OF MICROBIOLOGICAL METHODS, 1997, 30 (02) :141-152
[3]   Influence of materials for fixation implants on local infection - An experimental study of steel versus titanium DCP in rabbits [J].
Arens, S ;
Schlegel, U ;
Printzen, G ;
Ziegler, WJ ;
Perren, SM ;
Hansis, M .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1996, 78B (04) :647-651
[4]   ADHERENCE OF COAGULASE-NEGATIVE STAPHYLOCOCCI TO PLASTIC TISSUE-CULTURE PLATES - A QUANTITATIVE MODEL FOR THE ADHERENCE OF STAPHYLOCOCCI TO MEDICAL DEVICES [J].
CHRISTENSEN, GD ;
SIMPSON, WA ;
YOUNGER, JJ ;
BADDOUR, LM ;
BARRETT, FF ;
MELTON, DM ;
BEACHEY, EH .
JOURNAL OF CLINICAL MICROBIOLOGY, 1985, 22 (06) :996-1006
[5]   Bacterial biofilms: A common cause of persistent infections [J].
Costerton, JW ;
Stewart, PS ;
Greenberg, EP .
SCIENCE, 1999, 284 (5418) :1318-1322
[6]  
Costerton W, 2003, J CLIN INVEST, V112, P1466, DOI 10.1172/JCI200320365
[7]   Adherence of Staphylococcus aureus slime-producing strain variants to biomaterials used in orthopaedic surgery [J].
Gracia, E ;
Fernandez, A ;
Conchello, P ;
Lacleriga, A ;
Paniagua, L ;
Seral, F ;
Amorena, B .
INTERNATIONAL ORTHOPAEDICS, 1997, 21 (01) :46-51
[8]   Adhesion of Staphylococcus aureus to implants with different physicochemical characteristics [J].
Karlov, AV ;
Khlusov, IA ;
Pontak, VA ;
Ignatov, VP ;
Ivin, MA ;
Zinatulina, SY .
BULLETIN OF EXPERIMENTAL BIOLOGY AND MEDICINE, 2002, 134 (03) :277-280
[9]   Antimicrobial susceptibility of Staphylococcus aureus and Staphylococcus epidermidis biofilms isolated from infected total hip arthroplasty cases [J].
Nishimura, S ;
Tsurumoto, T ;
Yonekura, A ;
Adachi, K ;
Shindo, H .
JOURNAL OF ORTHOPAEDIC SCIENCE, 2006, 11 (01) :46-50
[10]   A microtiter-plate screening method for biofilm disinfection and removal [J].
Pitts, B ;
Hamilton, MA ;
Zelver, N ;
Stewart, PS .
JOURNAL OF MICROBIOLOGICAL METHODS, 2003, 54 (02) :269-276