Reliability evaluation of an aggregate power conversion unit in the off-grid PV-battery-based DC microgrid from local energy communities under dynamic and transient operation

被引:13
作者
Kuo, Tsai-Chi [1 ]
Trang Thi Pham [2 ,4 ]
Duong Minh Bui [3 ]
Phuc Duy Le [6 ]
Tan Luong Van [5 ]
Huang, Po-Tsang [2 ]
机构
[1] Natl Taiwan Univ Sci & Technol NTUST, Dept Ind Management, Taipei 10607, Taiwan
[2] Chung Yuan Christian Univ CYCU, Dept Ind & Syst Engn ISE, Chungli, Taiwan
[3] Vietnamese German Univ VGU, Fac Engn, Dept Elect & Comp Engn ECE, Binh Duong 75000, Vietnam
[4] Ho Chi Minh City Univ Econ & Finance UEF, Fac Econ, Ho Chi Minh City 70000, Vietnam
[5] Ho Chi Minh City Univ Food Ind HUFI, Dept Elect & Elect Engn, 140 Le Trong Tan, Ho Chi Minh City 70000, Vietnam
[6] Ho Chi Minh City Power Corp, Dept Adm, Ho Chi Minh City 70000, Vietnam
关键词
Bidirectional converter; Boost converter; Buck converter; DC microgrid; Dynamic operation; DC fault; And reliability; SYSTEM; INTEGRATION;
D O I
10.1016/j.egyr.2022.03.190
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In a rural/local energy community (LEC), a PV-battery-based DC microgrid (MG) normally operates at the off-grid/islanded mode. At this off-grid operation mode, the reliability of power converters in both the PV system and the battery energy storage system (BESS) could be reduced by dynamic operation scenarios of the DC microgrid which are frequently repeated, such as the intermittency of PV-system output power, the random fluctuation of load power. Indeed, the dynamic operation of the PV-generating system and the load system in the off-grid DC microgrid could lead to a certain decrease in the reliability of DC-DC bidirectional converters of the BESS, boost converters of the PV system, and buck converters for low-voltage DC loads because of withstanding different power flows to provide a source-load power balance in the DC microgrid. Moreover, transient operation scenarios of the off-grid DC microgrid can significantly impact the reliability of the mentioned power converters. To make the above assumptions more clear, reliability analysis of an aggregate power conversion unit (APCU) in the off-grid PV-battery-based DC microgrid under dynamic and transient operation in the local energy community is presented in this paper. The APCU contains the boost converter of the PV system, the bidirectional converter of the BESS, and the buck converter of the low-voltage DC load system. The main objective of the paper is to shed light on calculations of the dynamic-voltage-dependent failure rate (DVDFR) and fault-current-dependent failure rate (FCDFR) of the APCU from dynamic and transient operation conditions respectively in the off-grid LVDC microgrid. Then, a novel combination of the useful-time-dependent failure rate (UTDFR), the DVDFR, and the FCDFR is proposed to evaluate the system-level and component-level reliability of the APCU in the off-grid DC microgrid. Markov-state transition diagrams are applied for the APCU's reliability assessment. Experimental results show that the reliability of the bidirectional power converter is more affected by the dynamic and transient operation than that of the boost or buck converters in the APCU. In addition, the DVDFR of the APCU is almost smaller than its FCDFR, but the system-level reliability of the APCU could be significantly reduced by dynamic cases in the islanded DC microgrid. Last but not least, the MTTF and MTBF of the APCU could be dramatically decreased by the dynamic and transient operation of the DC microgrid. (c) 2022 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:5688 / 5726
页数:39
相关论文
共 47 条
  • [1] Reliability and economic assessment of a microgrid power system with the integration of renewable energy resources
    Adefarati, T.
    Bansal, R. C.
    [J]. APPLIED ENERGY, 2017, 206 : 911 - 933
  • [2] Reliability assessment of distribution system with the integration of renewable distributed generation
    Adefarati, T.
    Bansal, R. C.
    [J]. APPLIED ENERGY, 2017, 185 : 158 - 171
  • [3] Reliability and Cost Analysis of Multistage Boost Converters Connected to PV Panels
    Aghdam, Farid Hamzeh
    Abapour, Mehdi
    [J]. IEEE JOURNAL OF PHOTOVOLTAICS, 2016, 6 (04): : 981 - 989
  • [4] Reliability Analysis and Performance Degradation of a Boost Converter
    Alam, Mohammed Khorshed
    Khan, Faisal H.
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2014, 50 (06) : 3986 - 3994
  • [5] Beheshtaein S, 2019, IEEE J EMERG SEL TOP, P1, DOI 10.1109/JESTPE.2019.2904588
  • [6] Design and Implementation of the Battery Energy Storage System in DC Micro-Grid Systems
    Chang, Yuan-Chih
    Chang, Hao-Chin
    Huang, Chien-Yu
    [J]. ENERGIES, 2018, 11 (06):
  • [7] Dahale S, 2017, 2017 7TH INTERNATIONAL CONFERENCE ON POWER SYSTEMS (ICPS), P410, DOI 10.1109/ICPES.2017.8387329
  • [8] Luenberger Observer Based Current Estimated Boost Converter for PV Maximum Power Extraction-A Current Sensorless Approach
    Das, Dhiman
    Madichetty, Sreedhar
    Singh, Bhim
    Mishra, Sukumar
    [J]. IEEE JOURNAL OF PHOTOVOLTAICS, 2019, 9 (01): : 278 - 286
  • [9] A Unified Approach to Reliability Assessment of Multiphase DC-DC Converters in Photovoltaic Energy Conversion Systems
    Dhople, Sairaj V.
    Davoudi, Ali
    Dominguez-Garcia, Alejandro D.
    Chapman, Patrick L.
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2012, 27 (02) : 739 - 751
  • [10] Bui DM, 2014, ASIA-PAC POWER ENERG