Communication time delay estimation for load frequency control in two-area power system

被引:37
|
作者
Singh, Vijay P. [1 ]
Kishor, Nand [1 ]
Samuel, Paulson [1 ]
机构
[1] Motilal Nehru Natl Inst Technol Allahabad, Dept Elect Engn, Allahabad, Uttar Pradesh, India
关键词
Communication delay; Load frequency control; Markovian approach; Packet loss probability and particle swarm optimization; AUTOMATIC-GENERATION CONTROL; NETWORKED CONTROL-SYSTEMS; STABILITY; PARTICIPATION; STABILIZATION;
D O I
10.1016/j.adhoc.2015.10.010
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Due to increased size and complexity of power system network, the stability and load frequency control (LFC) is of serious concern in a wide area monitoring system (WAMS) having obtained signals from phasor measurement unit (PMU). The quality of services (QoS) for communication infrastructure in terms of signal delay, packet loss probability, queue length, throughput is very important and must be considered carefully in the WAMS based thermal power system. However, very few studies have been presented that includes QoS for communication infrastructure in load frequency control (LFC) of power system. So this paper presents LFC for two area thermal power system based on estimated time delay and packet loss probability using the Markovian approach. The delay and packet loss probability are modeled by different math functions. Normally, frequency deviation signal is transmitted from remote terminal unit (RTU) to control center and from control center to individual control unit of plants. The delay incurred is located in the forward loop of PSO based PI/PID controller in the form of transport delay. To verify the efficacy of controller performance, the estimated constant delay and time varying delay are applied to the controller in the two area thermal thermal power system with and without governor dead band (GDB) and generation rate constraints (GRC) for various loads conditions. The study is further demonstrated for time delay, being compensated by 2nd order Pade approximation. The results show that frequency deviation is minimum in terms of stability and transient response. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:69 / 85
页数:17
相关论文
共 50 条
  • [41] Effects on Load-Frequency Control of a Solar Power System with a Two-Area Interconnected Thermal Power Plant and its Control with a New BFA Algorithm
    Civelek, Zafer
    Gorel, Goksu
    Luy, Murat
    Barisci, Necaattin
    Cam, Ertugrul
    ELEKTRONIKA IR ELEKTROTECHNIKA, 2018, 24 (06) : 3 - 10
  • [42] Differential Evolution Algorithm Based Load Frequency Control in a Two-Area Conventional and Renewable Energy Based Nonlinear Power System
    Zamee, Muhammad Ahsan
    Islam, Kazi Khairul
    Ahmed, Ashik
    Zafreen, Kazi Rehnuma
    2016 4TH INTERNATIONAL CONFERENCE ON THE DEVELOPMENT IN THE IN RENEWABLE ENERGY TECHNOLOGY (ICDRET), 2016,
  • [43] Dynamic Tuning of the Controller Parameters in a Two-Area Multi-Source Power System for Optimal Load Frequency Control Performance
    Gbadega, Peter Anuoluwapo
    Saha, Akshay Kumar
    INTERNATIONAL JOURNAL OF ENGINEERING RESEARCH IN AFRICA, 2020, 51 : 111 - 129
  • [44] Load Frequency Control of Two-area Interconnected Power System Using Optimal Controller, PID Controller and Fuzzy Logic Controller
    Basavarajappa, S. R.
    Nagaraj, M. S.
    HELIX, 2020, 10 (03): : 30 - 35
  • [45] Decentralized Robust Control for Two-Area Interconnected Power System
    Wang, Wei
    Ohmori, Hiromitsu
    2015 AMERICAN CONTROL CONFERENCE (ACC), 2015, : 3656 - 3663
  • [46] Computation of stability regions for time-delayed two-area load frequency control system including dynamic demand response
    Katipoglu, Deniz
    Sonmez, Sahin
    Ayasun, Saffet
    JOURNAL OF THE FACULTY OF ENGINEERING AND ARCHITECTURE OF GAZI UNIVERSITY, 2024, 39 (01): : 431 - 442
  • [47] Optimized Intelligent Coordinator for Load Frequency Control in a Two-Area System with PV Plant and Thermal Generator
    Davtalab, Sajad
    Tousi, Behrouz
    Nazarpour, Dariush
    IETE JOURNAL OF RESEARCH, 2022, 68 (05) : 3876 - 3886
  • [48] Delay-dependent stability analysis of a two-area load frequency control system including electric vehicle aggregator and dynamic demand response
    Tek, Bilal
    Sonmez, Sahin
    Ayasun, Saffet
    2020 12TH INTERNATIONAL CONFERENCE ON ELECTRICAL AND ELECTRONICS ENGINEERING (ELECO), 2020, : 178 - 182
  • [49] Frequency Consensus Control for Two-area Flexible DC Interconnected System
    Li, Pengfei
    Li, Xialin
    Guo, Li
    Huang, Di
    PROCEEDINGS OF THE 38TH CHINESE CONTROL CONFERENCE (CCC), 2019, : 7304 - 7309
  • [50] Adaptive Jaya Algorithm for Optimized PI-PD Cascade Controller of Load Frequency Control in Interconnected Two-Area Power System
    Pradhan, Chittaranjan
    Gjengedal, Terje
    PROCEEDINGS OF 2020 INTERNATIONAL CONFERENCE ON SMART SYSTEMS AND TECHNOLOGIES (SST 2020), 2020, : 181 - 186