A symmetric nonrigid registration method to handle large organ deformations in cervical cancer patients

被引:68
作者
Bondar, Luiza [1 ]
Hoogeman, Mischa S. [1 ]
Osorio, Eliana M. Vasquez [1 ]
Heijmen, Ben J. M. [1 ]
机构
[1] Erasmus MC Daniel den Hoed Canc Ctr, Dept Radiat Oncol, NL-3075 EA Rotterdam, Zuid Holland, Netherlands
关键词
symmetric nonrigid registration; registration consistency; cervical cancer; image guided radiotherapy; large organ deformation; DEFORMABLE IMAGE REGISTRATION; RADIATION-THERAPY; PROSTATE-CANCER; RADIOTHERAPY; SEGMENTATION; ALGORITHM; SPLINES; FUSION; MODELS; CT;
D O I
10.1118/1.3443436
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Modern radiotherapy requires assessment of patient anatomical changes. By using unidirectional registration methods, the quantified anatomical changes are asymmetric, i.e., depend on the direction of the registration. Moreover, the registration is challenged by the large and complex organ deformations that can occur in, e. g., cervical cancer patients. The aim of this work was to develop, test, and validate a symmetric feature-based nonrigid registration method that can handle organs with large-scale deformations. Methods: A symmetric version of the unidirectional thin plate spline robust point matching (TPS-RPM) algorithm was developed, implemented, tested, and validated. Tests were performed by using the delineated cervix and uterus and bladder in CT scans of five cervical cancer patients. For each patient, five CT scans with a large variability in organ shape, volume, and deformations were acquired. Both the symmetric and the unidirectional algorithm were employed to calculate the registration geometric accuracy (surface distance and surface coverage errors), the inverse consistency, the residual distances after transforming anatomical landmarks, and the registration time. Additionally, to facilitate the further use of our symmetric method, a large set of input parameters was tested. Results: The developed symmetric algorithm handled successfully the registration of bladders with extreme volume change for which TPS-RPM failed. Compared to the unidirectional algorithm the symmetric algorithm improved, for the registration of organs with large volume change, the inverse consistency by 78% and the surface coverage by 46%. Similarly, for organs with small volume change, the symmetric algorithm improved the inverse consistency by 69% and the surface coverage by 13%. The method allowed for anatomically coherent registration in only 35 s for cervixuterus and 151 s for bladder, while keeping the inverse consistency errors around 1 mm and the surface matching errors below 1 mm. Compared to rigid alignment the symmetric method reduced the residual distances between anatomical landmarks from a range of 5.8 +/- 2-70.1 +/- 20.1 mm to a range of 1.9 +/- 0.2-8.5 +/- 5.2 mm. Conclusions: The developed symmetric method could be employed to perform fast, accurate, consistent, and anatomically coherent registration of organs with large and complex deformations. Therefore, the method is a useful tool that could support further developments in high precision image guided radiotherapy. (C) 2010 American Association of Physicists in Medicine. [DOI: 10.1118/1.3443436]
引用
收藏
页码:3760 / 3772
页数:13
相关论文
共 40 条
[21]   Image registration and data fusion in radiation therapy [J].
Kessler, M. L. .
BRITISH JOURNAL OF RADIOLOGY, 2006, 79 :S99-S108
[22]   Automatic nonrigid registration of whole body CT mice images [J].
Li, Xia ;
Yankeelov, Thomas E. ;
Peterson, Todd E. ;
Gore, John C. ;
Dawant, Benoit M. .
MEDICAL PHYSICS, 2008, 35 (04) :1507-1520
[23]   PELVIC RADIOTHERAPY FOR CANCER OF THE CERVIX: IS WHAT YOU PLAN ACTUALLY WHAT YOU DELIVER? [J].
Lim, Karen ;
Kelly, Valerie ;
Stewart, James ;
Xie, Jason ;
Cho, Young-Bin ;
Moseley, Joanne ;
Brock, Kristy ;
Fyles, Anthony ;
Lundin, Anna ;
Rehbinder, Henrik ;
Milosevic, Michael .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 74 (01) :304-312
[24]   Automatic 3d free form shape matching using the graduated assignment algorithm [J].
Liu, YG .
PATTERN RECOGNITION, 2005, 38 (10) :1615-1631
[25]  
Maintz J B, 1998, Med Image Anal, V2, P1, DOI 10.1016/S1361-8415(01)80026-8
[26]   Advances in Geometric Morphometrics [J].
Mitteroecker, Philipp ;
Gunz, Philipp .
EVOLUTIONARY BIOLOGY, 2009, 36 (02) :235-247
[27]   Local anatomic changes in parotid and submandibular glands during radiotherapy for oropharynx cancer and correlation with dose, studied in detail with nonrigid registration [J].
Osorio, Eliana M. Vasquez ;
Hoogeman, Mischa S. ;
Al-Mamgani, Abrahim ;
Teguh, David N. ;
Levendag, Peter C. ;
Heijmen, Ben J. M. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 70 (03) :875-882
[28]   A novel flexible framework with automatic feature correspondence optimization for nonrigid registration in radiotherapy [J].
Osorio, Eliana M. Vasquez ;
Hoogeman, Mischa S. ;
Bondar, Luiza ;
Levendag, Peter C. ;
Heijmen, Ben J. M. .
MEDICAL PHYSICS, 2009, 36 (07) :2848-2859
[29]  
OSORIO EMV, 2010, 16 INT C US COMP RAD
[30]   Symmetric image registration [J].
Rogelj, P ;
Kovacic, S .
MEDICAL IMAGE ANALYSIS, 2006, 10 (03) :484-494