Biological and environmental factors affecting ultrasound-induced hemolysis in vitro:: Medium tonicity

被引:9
作者
Miller, MW [1 ]
Battaglia, LF [1 ]
Mazza, S [1 ]
机构
[1] Univ Rochester, Sch Med & Dent, Dept Obstet & Gynecol, Rochester, NY 14642 USA
关键词
ultrasound; hemolysis in vitro; medium tonicity;
D O I
10.1016/S0301-5629(03)00010-3
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Whole human anticoagulated blood in vitro underwent controlled plasma replacement with either isotonic (0.9%) or hypotonic (0.5%) saline to 1. restore the blood to its original volume (which resulted in different hematocrits) or 2. bring the blood to a singular hematocrit (40%). The hypotonic cell MCVs were, on average, considerably larger than their isotonic counterpart by a ratio of 1.4:1. The blood samples were then subjected to two tests, one of mechanical fragility, the other to ultrasound (US)-induced hemolysis. The US exposure metrics were: 1.0-MHz center frequency, 200-mus pulse duration, 20-ms interpulse interval, exposure durations of 10 to 30 s in the presence of Albunex(R), as a control on blood gas nucleation, and exposure vessel rotation at 200 rpm. In all instances, the hypotonic blood displayed higher levels of. hemolysis than the corresponding isotonic treatment. The highest ratio of US-induced hemolysis for the hypotonic:isotonic regimens was 2.2. In some instances, the ratio was somewhat less but appeared to be related to differences in whole blood viscosities among the regimens or other factors. The data supported the a priori hypothesis that hypotonicity will result in an increased tension on the cell membrane and render it more susceptible to shear-induced hemolysis, including exposure to US under conditions known to foster the occurrence of inertial cavitation. There was no temperature increase during the insonations of the blood. (C) 2003 World Federation for Ultrasound in Medicine Biology.
引用
收藏
页码:713 / 724
页数:12
相关论文
共 50 条
[1]   HUMAN RED-CELL HEMOLYSIS RATES IN SUBSECOND TO SECONDS RANGE - AN ANALYSIS [J].
ANDERSON, PC ;
LOVRIEN, RE .
BIOPHYSICAL JOURNAL, 1977, 20 (02) :181-191
[2]  
[Anonymous], 1995, STEDMANS MED DICT
[3]  
[Anonymous], 2002, 140 NCRP
[4]   Temporality in ultrasound-induced cell lysis in vitro [J].
Azadniv, M ;
Doida, Y ;
Miller, MW ;
Brayman, AA ;
Meltzer, RS .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1996, 13 (01) :45-55
[5]  
BLACKSHEAR PL, 1987, HDB BIOENGINEERING
[6]   ULTRASONIC CHARACTERIZATION OF ALBUNEX, A NEW CONTRAST AGENT [J].
BLEEKER, HJ ;
SHUNG, KK ;
BARNHART, JL .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1990, 87 (04) :1792-1797
[7]   Hemolysis of 40% hematocrit, Albunex(R)-supplemented human erythrocytes by pulsed ultrasound: Frequency, acoustic, pressure and pulse length dependence [J].
Brayman, AA ;
Strickler, PL ;
Luan, H ;
Barned, SL ;
Raeman, CH ;
Cox, C ;
Miller, MW .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (08) :1237-1250
[8]   LYSIS OF ERYTHROCYTES BY EXPOSURE TO CW ULTRASOUND [J].
CARSTENSEN, EL ;
KELLY, P ;
CHURCH, CC ;
BRAYMAN, AA ;
CHILD, SZ ;
RAEMAN, CH ;
SCHERY, L .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1993, 19 (02) :147-165
[9]   DIFFERENCES BETWEEN YOUNG AND MATURE RABBIT ERYTHROCYTES [J].
CHALFIN, D .
JOURNAL OF CELLULAR AND COMPARATIVE PHYSIOLOGY, 1956, 47 (02) :215-243
[10]  
CHAMPION J V, 1971, Biorheology, V8, P23