Using the classification model of an electronic nose to assign unknown malodours to environmental sources and to monitor them continuously

被引:58
作者
Nicolas, J [1 ]
Romain, AC [1 ]
Wiertz, V [1 ]
Maternova, J [1 ]
André, P [1 ]
机构
[1] Fdn Univ Luxembourgeoise, Dept Environm Monitoring, B-6700 Arlon, Belgium
关键词
electronic nose; real malodours; field monitoring;
D O I
10.1016/S0925-4005(00)00487-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The paper provides some considerations resulting from measurements with electronic noses around real sources of malodour in the environment: compost facilities, printing houses, paint shops, waste water treatment plants, rendering plants, settling ponds of sugar factories. The study aims at supplying the concrete information requested by the final user in the field: either a warning signal when the malodour level exceeds some given threshold value, the identification of the source of an odour detected on site, or on-line identification and monitoring of an odour in the field. Very simple instruments are used, either in the laboratory or directly in the field, with a home-made portable e-nose, based on tin oxide sensors. Even with such simple operating conditions, the classification results with DA and PCA are fairly good. The classification functions calibrated with the statistical procedure, on the basis of the learning phase, are used to recognise and to monitor a given malodour. This odour is sometimes mixed with other odorous interferences in the field. The observations reveal some features useful in the frame of the development of a field detector. (C) 2000 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:366 / 371
页数:6
相关论文
共 9 条
[1]  
Gardner JW, 1997, INSIGHT, V39, P865
[2]   ASSESSMENT OF ODORS FROM LIVESTOCK WASTES BY A PHOTOIONIZATION DETECTOR, AN ELECTRONIC NOSE, OLFACTOMETRY AND GAS-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
HOBBS, PJ ;
MISSELBROOK, TH ;
PAIN, BF .
JOURNAL OF AGRICULTURAL ENGINEERING RESEARCH, 1995, 60 (02) :137-144
[3]  
NICOLAS J, 1999, EURODER99 PARIS 15 1
[4]   Assessment of conducting polymer odour sensors for agricultural malodour measurements [J].
Persaud, KC ;
Khaffaf, SM ;
Hobbs, PJ ;
Sneath, RW .
CHEMICAL SENSES, 1996, 21 (05) :495-505
[5]   Air quality monitoring by means of sol-gel integrated tin oxide thin films [J].
Rella, R ;
Siciliano, P ;
Capone, S ;
Epifani, M ;
Vasanelli, L ;
Licciulli, A .
SENSORS AND ACTUATORS B-CHEMICAL, 1999, 58 (1-3) :283-288
[6]  
Romain A.-C., 1997, Semin. Food Anal, V2, P283
[7]  
ROMAIN AC, IN PRESS SENSORS A B
[8]   Assessment of odours from sewage treatment works by an electronic nose, H2S analysis and olfactometry [J].
Stuetz, RM ;
Fenner, RA ;
Engin, G .
WATER RESEARCH, 1999, 33 (02) :453-461
[9]  
Tabachnick, 2013, Using multivariate statistics, V6th