Efficient Operation of Air-Side Economizer Using Extremum Seeking Control

被引:42
作者
Li, Pengfei [1 ]
Li, Yaoyu [1 ]
Seem, John E. [2 ]
机构
[1] Univ Wisconsin, Dept Mech Engn, Milwaukee, WI 53211 USA
[2] Johnson Controls Inc, Bldg Efficiency Res Grp, Milwaukee, WI 53209 USA
来源
JOURNAL OF DYNAMIC SYSTEMS MEASUREMENT AND CONTROL-TRANSACTIONS OF THE ASME | 2010年 / 132卷 / 03期
关键词
energy conservation; energy consumption; HVAC; optimal control; SYSTEM;
D O I
10.1115/1.4001216
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
As the heating, ventilating, and air conditioning (HVAC) systems accounts for a major sector of energy consumption for commercial buildings, there has been a greater demand for improving the efficiency of such systems. The air-side economizers have been developed as a class of energy-saving HVAC devices that may increase the energy efficiency by taking advantage of outdoor air during cool or cold weather. However, many economizers do not operate in the expected manner and waste even more energy than before installation, mostly due to the unreliable sensors and actuators in practice. Better control strategy is needed for optimal and robust operation. In this paper, an extremum-seeking control (ESC) based self-optimizing strategy is proposed to minimize the energy consumption, with the feedback of chilled water supply command rather than the temperature and humidity measurements. The mechanical cooling load is minimized by seeking the optimal outdoor air damper opening in real time. Such scheme does not need temperature and humidity sensors, and depends much less on the knowledge of the economizer model. Simulation was performed on a MODELICA based transient model of a single-duct air-handling unit developed with DYMOLA and AIRCONDITIONING LIBRARY. The simulation results demonstrated the potential of using ESC to achieve the minimal mechanical cooling load in a self-optimizing manner. In addition, an antiwindup ESC scheme is proposed to handle the ESC windup issue due to actuator (damper) saturation. The simulation results validated the effectiveness of the proposed antiwindup ESC.
引用
收藏
页码:1 / 10
页数:10
相关论文
共 47 条
  • [1] *AEC, 2007, 50003030 AEC CAL EN
  • [2] [Anonymous], 1997, COMPUTER CONTROLLED
  • [3] *ASHRAE INC, 2001, ASHRAE STAND VEN ACC
  • [4] *ASHRAE INC, 2004, EN STAND BUILD EXC L
  • [5] *ASHRAE INC, 2004, 90 1 US MAN ANSI ASH
  • [6] Astrom K. J., 1989, Proceedings of the 1989 American Control Conference (Cat. No.89CH2772-2), P1693
  • [7] Astrom K.J., 1996, Computer-Controlled Systems: Theory and Design, Vthird
  • [8] Astrom K.J., 1995, ADAPTIVE CONTROL
  • [9] ASTROM KJ, 1987, P 13 ANN ADV CONTR C
  • [10] Banaszuk A, 2000, P AMER CONTR CONF, P416, DOI 10.1109/ACC.2000.878934