Evaluation of ELISA and CLIA for Treponema pallidum specific antibody detection in China: A multicenter study

被引:6
|
作者
Ji, Huimin [1 ,2 ,3 ]
Chang, Le [1 ,2 ]
Zhao, Junpeng [1 ,2 ,3 ]
Zhang, Lu [1 ,2 ,3 ]
Jiang, Xinyi [1 ,2 ,3 ]
Guo, Fei [1 ,2 ]
Wang, Lunan [1 ,2 ,3 ]
机构
[1] Beijing Hosp, Natl Ctr Gerontol, Natl Ctr Clin Labs, 1 Dahua Rd, Beijing 100730, Peoples R China
[2] Beijing Hosp, Beijing Engn Res Ctr Lab Med, Beijing, Peoples R China
[3] Chinese Acad Med Sci, Peking Union Med Coll, Grad Sch, Beijing, Peoples R China
关键词
Treponema pallidum specific antibody; Electro-chemiluminescence immunoassays (ECLIA); Chemiluminescence immunoassays (CLIA); ELISA; SYPHILIS; POLYPEPTIDES; TESTS;
D O I
10.1016/j.mimet.2019.105742
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: Considering the rapid increase of syphilis infections in several countries including China, searching for a screening test with sufficient sensitivity and specificity is extremely urgent. The current study mainly researched the performance for Treponema pallidum (TP) detection by electro-chemiluminescence immunoassays (ECLIA), chemiluminescence immunoassays (CLIA) and four commercially available ELISA assays commonly used in China. Methods: 1372 plasma samples collected from blood centers/banks were tested with 6 assays in 8 laboratories with the Western blot (WB) or TP particle agglutination assay (TPPA) as confirmatory tests. Results: With the WB or TPPA as confirmatory test, the ECLIA demonstrated the highest specificity (95.2%) and Kappa coefficient (0.915), but lowest sensitivity (97.2%) compared with the other 5 assays. While the Wantai-ELISA showed the highest sensitivity (99.6%) among the 6 assays. Sensitivities were found to be significantly increased when any two of the six assays were combined for TP detection. Our study demonstrated that the Wantai-ELISA combined with the ECLIA or the KHB-ELISA or the InTec-ELISA would increase the sensitivities up to 100%. Further analysis showed that the specificities and positive predictive values were both 100.0% when cut-off of S/CO values were served as 15.42 for the ECLIA and 7.14 for the CLIA, indicating that samples under these conditions can be directly considered as positive without confirmation. Conclusions: The CLIA and the ECLIA are more specific than ELISA to detect TP antibodies. However, ELISA is a sensitive method, especially in combination with the CLIA or the ECLIA or another types of ELISA, suitable for the routine screening of blood donations in China.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Performance Evaluation of CLIA for Treponema Pallidum Specific Antibodies Detection in Comparison with ELISA
    Li, Lixin
    Cai, Bei
    Tao, Chuanmin
    Wang, Lanlan
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2016, 30 (03) : 216 - 222
  • [2] Plasmonic ELISA for the ultrasensitive detection of Treponema pallidum
    Nie, Xin-Min
    Huang, Rong
    Dong, Cai-Xia
    Tang, Li-Juan
    Gui, Rong
    Jiang, Jian-Hui
    BIOSENSORS & BIOELECTRONICS, 2014, 58 : 314 - 319
  • [3] Evaluation of three automated Treponema pallidum antibody assays for syphilis screening
    Xia, Chang-sheng
    Yue, Zhi-hong
    Wang, Hui
    JOURNAL OF INFECTION AND CHEMOTHERAPY, 2018, 24 (11) : 887 - 891
  • [4] Evaluation of a New Recombinant Antigen-Based Virotech Treponema Pallidum Screen ELISA for Diagnosis of Syphilis
    Busse, Clemens
    Navid, Mojdeh Heidary
    Strubel, Andreas
    Schnitzler, Paul
    CLINICAL LABORATORY, 2013, 59 (5-6) : 523 - 529
  • [5] Prevalence of Treponema Pallidum Antibody among Volunteer Blood Donors in China
    Zheng, Xiaofan
    Ding, Wei
    Ling, Xia
    Shi, Jie
    Dong, Jie
    Yu, Guangshu
    Chen, Yan
    Li, Rui
    Xu, Lihong
    Li, Xiaotao
    Zhu, Hong
    Zhu, Faming
    Hu, Wei
    CANADIAN JOURNAL OF INFECTIOUS DISEASES & MEDICAL MICROBIOLOGY, 2022, 2022
  • [6] The analyzation and clinical evaluation of ECLIA and CMIA in the detection of Treponema pallidum
    Zhou, Jiansuo
    Liang, Yongming
    Zhang, Jie
    Cui, Liyan
    MEDICINE, 2017, 96 (24)
  • [7] Treponema pallidum-specific antibody expression for the diagnosis of different stages of syphilis
    Sun Ran
    Lai Di-hui
    Ren Rong-xin
    Lian Shi
    Zhang Hai-ping
    CHINESE MEDICAL JOURNAL, 2013, 126 (02) : 206 - 210
  • [8] Performance Evaluation of a Novel Chemiluminescence Assay Detecting Treponema Pallidum Antibody as a Syphilis Screening Method
    Chen, Qixia
    An, Jingna
    Rao, Chenli
    Wang, Tingting
    Li, Dongdong
    Feng, Shu
    Tao, Chuanmin
    CLINICAL LABORATORY, 2016, 62 (04) : 519 - 526
  • [9] Clinical Evaluation of Fully Automated Elecsys® Syphilis Assay for the Detection of Antibodies of Treponema pallidum
    Li, Dongdong
    An, Jingna
    Wang, Tingting
    Tao, Chuanmin
    Wang, Lanlan
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2016, 30 (06) : 1164 - 1168
  • [10] Urea-mediated dissociation alleviate the false-positive Treponema pallidum-specific antibodies detected by ELISA
    Wang, Qiang
    Lei, Yan
    Lu, Xiaolan
    Wang, Guangrong
    Du, Qin
    Guo, Xiaolan
    Xing, Yan
    Zhang, Guoyuan
    Wang, Dongsheng
    PLOS ONE, 2019, 14 (03):