High Field Cardiac Magnetic Resonance Imaging - Current and Future Perspectives

被引:10
作者
Cheng, Adrian S. H. [2 ]
Selvanayagam, Joseph B. [1 ]
机构
[1] Flinders Univ S Australia, Flinders Med Ctr, Dept Cardiovasc Med, Bedford Pk, SA 5042, Australia
[2] Heart Hosp, London, England
关键词
Magnetic resonance imaging; 3; Tesla; High field; CORONARY-ARTERY-DISEASE; MYOCARDIAL-PERFUSION MR; EMISSION-COMPUTED-TOMOGRAPHY; SENSITIVE-INVERSION-RECOVERY; INFARCT SIZE MEASUREMENT; TESLA; 3.0; T; TRANSMURAL EXTENT; STRESS PERFUSION; INTERSTUDY REPRODUCIBILITY;
D O I
10.1016/j.hlc.2009.11.008
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Potential advantages of high field cardiac magnetic resonance imaging include superior signal-to-noise ratio, image contrast and spectral separation. These might be used to improve spatial and/or temporal resolution and imaging speed. However, high field imaging presents new challenges to the operator, including increased magnetic field heterogeneity, susceptibility, artefacts and higher specific absorption rate. Recently, studies have reported on the clinical utility of cardiac magnetic resonance imaging at 3 Tesla in the assessment of myocardial function, perfusion and viability, and coronary arteries. The results of these clinical studies are reviewed, as well as emerging applications in myocardial tagging and cardiac spectroscopy. (Heart, Lung and Circulation 2010;19:145-153) (C) 2010 Australasian Society of Cardiac and Thoracic Surgeons and the Cardiac Society of Australia and New Zealand. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:145 / 153
页数:9
相关论文
共 94 条
  • [1] Noninvasive detection of myocardial ischemia from perfusion reserve based on cardiovascular magnetic resonance
    Al-Saadi, N
    Nagel, E
    Gross, M
    Bornstedt, A
    Schnackenburg, B
    Klein, C
    Klimek, W
    Oswald, H
    Fleck, E
    [J]. CIRCULATION, 2000, 101 (12) : 1379 - 1383
  • [2] Normal human left and right ventricular dimensions for MRI as assessed by turbo gradient echo and steady-state free precession imaging sequences
    Alfakih, K
    Plein, S
    Thiele, H
    Jones, T
    Ridgway, JP
    Sivananthan, MU
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 17 (03) : 323 - 329
  • [3] [Anonymous], GUID IND FDA STAFF E
  • [4] 3 Tesla MR imaging provides improved contrast in first-pass myocardial perfusion imaging over a range of gadolinium doses
    Araoz, PA
    Glockner, JF
    Mcgee, KP
    Potter, DD
    Valeti, VU
    Stanley, DW
    Christian, TF
    [J]. JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2005, 7 (03) : 559 - 564
  • [5] EFFECT OF PERFUSION-PRESSURE DISTAL TO A CORONARY STENOSIS ON TRANSMURAL MYOCARDIAL BLOOD-FLOW
    BACHE, RJ
    SCHWARTZ, JS
    [J]. CIRCULATION, 1982, 65 (05) : 928 - 935
  • [6] Reduction in sample size for studies of remodeling in heart failure by the use of cardiovascular magnetic resonance
    Bellenger, NG
    Davies, LC
    Francis, JM
    Coats, AJS
    Pennell, DJ
    [J]. JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2000, 2 (04) : 271 - 278
  • [7] Imaging artifacts at 3.OT
    Bernstein, Matt A.
    Huston, John, III
    Ward, Heidi A.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 24 (04) : 735 - 746
  • [8] Three-dimensional breathhold SSFP coronary MRA: A comparison between 1.5T and 3.OT
    Bi, XM
    Deshpande, V
    Simonetti, O
    Laub, G
    Li, DB
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 22 (02) : 206 - 212
  • [9] Initial experiences with in vivo right coronary artery human MR vessel wall imaging at 3 tesla
    Botnar, RM
    Stuber, M
    Lamerichs, R
    Smink, J
    Fischer, SE
    Harvey, P
    Manning, WJ
    [J]. JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2003, 5 (04) : 589 - 594
  • [10] Cardiac magnetic resonance imaging:: long term reproducibility of the late enhancement signal in patients with chronic coronary artery disease
    Bülow, H
    Klein, C
    Kuehn, I
    Hollweck, R
    Nekolla, SG
    Schreiber, K
    Haas, F
    Böhm, J
    Schnackenburg, B
    Lange, R
    Schwaiger, M
    [J]. HEART, 2005, 91 (09) : 1158 - 1163