Results of endografting of the aortic arch in different landing zones

被引:127
作者
Melissano, G. [1 ]
Civilini, E. [1 ]
Bertoglio, L. [1 ]
Calliari, F. [1 ]
Setacci, F. [1 ]
Calori, G. [1 ]
Chiesa, R. [1 ]
机构
[1] Univ Vita Salute San Raffaele, Dept Vasc Surg, Sci Inst Hosp San Raffaele, IRCCS, I-20132 Milan, Italy
关键词
aortic arch; endovascular treatment; stent-graft; hybrid procedure; supra-aortic debranching;
D O I
10.1016/j.ejvs.2006.11.019
中图分类号
R61 [外科手术学];
学科分类号
摘要
Introduction. Endovascular approach to the aortic arch is an appealing solution for selected patients. Aim of this study is to compare the technical and clinical success recorded in the different anatomical settings of endografting for aortic arch disease. Methods. Between June 1999 and October 2006, among 178 patients treated at our Institution for thoracic aorta disease with a stent-graft, the aortic arch was involved in 64 cases. According to the classification proposed by Ishimaru, aortic '' zone 0 '' was involved in 14 cases, '' zone 1 '' in 12 cases and '' zone 2 '' in 38 cases. A hybrid surgical procedure of supraortic debranching and revascularization was performed in 37 cases to obtain an adequate proximal aortic landing zone. Results. '' Zone 0 '' (14 cases). Proximal neck length: 44 6 mm. Initial clinical success 78.6%: 2 deaths (stroke), I type la endoleak. At a mean follow-up of 16.4 +/- 11 months the midterm clinical success was 85.7%. '' Zone 1 '' (12 cases). Proximal neck length: 28 +/- 5 min. Initial clinical success 66.7%: 0 deaths, 4 type la endoleaks. At a mean follow-up of 16.9 +/- 17.2 months the midterm clinical success was 75.0%. '' Zone 2 '' (38 cases) Proximal neck length: 30 +/- 5 mm. Initial clinical success 84.2%: 2 deaths (1 cardiac arrest, 1 multiorgan embolization), 3 type la endoleaks, 1 case of open conversion. Two cases of delayed transitory paraparesis/paraplegia were observed. At a mean follow-up of 28.0 +/- 17.2 months the midterm clinical success was 89.5%. Conclusions. Total debranching of the arch for '' zone 0 '' aneurysms allowed to obtain a longer proximal aortic landing zone with lower incidence of endoleak, however a higher risk of cerebrovascular accident was observed. The relatively high incidence of adverse events in '' zone 1 '' could be associated to a shorter proximal neck, therefore this landing zone is reserved for patients unfit for sternotomy. In case of endoleak, discovered after a satisfactorily positioned endograft in the arch, the rate of spontaneous resolution within the first 6 months is high.
引用
收藏
页码:561 / 566
页数:6
相关论文
共 22 条
[1]   Endovascular thoracic aortic repair and previous or concomitant abdominal aortic repair: Is the increased risk of spinal cord ischemia real? [J].
Baril, DT ;
Carroccio, A ;
Ellozy, SH ;
Palchik, E ;
Addis, MD ;
Jacobs, TS ;
Teodorescu, V ;
Marin, ML .
ANNALS OF VASCULAR SURGERY, 2006, 20 (02) :188-194
[2]   Great vessel management for endovascular exclusion of aortic arch aneurysms and dissections [J].
Bergeron, P. ;
Mangialardi, N. ;
Costa, P. ;
Coulon, P. ;
Douillez, V. ;
Serreo, E. ;
Tuccimei, I. ;
Cavazzini, C. ;
Mariotti, F. ;
Sun, Y. ;
Gay, J. .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2006, 32 (01) :38-45
[3]   Reporting standards for endovascular aortic aneurysm repair [J].
Chaikof, EL ;
Blankensteijn, JD ;
Harris, PL ;
White, GH ;
Zarins, CK ;
Bernhard, VM ;
Matsumura, JS ;
May, J ;
Veith, FJ ;
Fillinger, MF ;
Rutherford, RB ;
Kent, KC .
JOURNAL OF VASCULAR SURGERY, 2002, 35 (05) :1048-1060
[4]   Spinal cord ischemia after elective stent-graft repair of the thoracic aorta [J].
Chiesa, R ;
Melissano, G ;
Marrocco-Trischitta, MM ;
Civilini, E ;
Setacci, F .
JOURNAL OF VASCULAR SURGERY, 2005, 42 (01) :11-17
[5]   Modular branched stent graft for endovascular repair of aortic arch aneurysm and dissection [J].
Chuter, TAM ;
Schneider, DB ;
Reilly, LM ;
Lobo, EP ;
Messina, LM .
JOURNAL OF VASCULAR SURGERY, 2003, 38 (04) :859-863
[6]   Endovascular repair of the thoracic aorta: Lessons learned [J].
Criado, FJ ;
Abul-Khoudoud, OR ;
Domer, GS ;
McKendrick, C ;
Zuzga, M ;
Clark, NS ;
Monaghan, K ;
Barnatan, MF .
ANNALS OF THORACIC SURGERY, 2005, 80 (03) :857-863
[7]   Stent graft repair in the aortic arch and descending thoracic aorta: A 4-year experience [J].
Criado, FJ ;
Clark, NS ;
Barnatan, MF .
JOURNAL OF VASCULAR SURGERY, 2002, 36 (06) :1121-1127
[8]   Transposition of the supraaortic branches for extended endovascular arch repair [J].
Czerny, Martin ;
Gottardi, Roman ;
Zimpfer, Daniel ;
Schoder, Maria ;
Grabenwoger, Martin ;
Lammer, Johannes ;
Wolner, Ernst ;
Grimm, Michael .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2006, 29 (05) :709-713
[9]   Results of endovascular repair of the thoracic aorta with the talent thoracic stent graft:: The Talent Thoracic Retrospective Registry [J].
Fattori, Rossella ;
Nienaber, Christoph A. ;
Rousseau, Herve ;
Beregi, Jean-Paul ;
Heijmen, Robin ;
Grabenwoeger, Martin ;
Piquet, Philippe ;
Lovato, Luigi ;
Dabbech, Chaouki ;
Kische, Stephan ;
Gaxotte, Virginia ;
Schepens, Marc ;
Ehrlich, Marek ;
Bartoli, Jean-Michelle .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2006, 132 (02) :332-339
[10]  
Görich J, 2002, J ENDOVASC THER, V9, P39