Torsional repair of damaged single-box multi-cell composite box-girder with corrugated steel webs using CFRP. Part I: Experimental investigation

被引:8
作者
Zhu, Yingbo [1 ]
Shen, Kongjian [2 ,3 ]
Wan, Shui [2 ]
Brigham, John C. [1 ]
Fascetti, Alessandro [1 ]
Zhou, Peng [2 ]
机构
[1] Univ Pittsburgh, Dept Civil & Environm Engn, Pittsburgh, PA 15261 USA
[2] Southeast Univ, Sch Transportat, Nanjing 210096, Peoples R China
[3] Jiangsu Prov Transportat Engn Construct Bur, Nanjing 210004, Peoples R China
基金
中国国家自然科学基金;
关键词
Repair; CFRP; Damaged composite box-girder; Damaged concrete; Corrugated steel webs; Torsional behavior; REINFORCED-CONCRETE BEAMS; SOFTENED MEMBRANE MODEL; RC BEAMS; FLEXURAL BEHAVIOR; SHEAR CAPACITY; FLANGED BEAMS; CYCLIC SHEAR; FRP; BRIDGES; ELEMENTS;
D O I
10.1016/j.compstruct.2022.115920
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
In the last two decades, Composite Box-Girders with Corrugated Steel Webs (CBGCSWs) have been extensively used in construction, but more research is still needed to fully characterize their mechanical behavior such as their torsional stiffness exhibiting a sharp decrease compared with concrete structures, due to the employment of the thin corrugated steel webs. Further, wide Single-Box Multi-Cell CBGCSWs (SBMC-CBGCSWs) under heavy eccentric load are more likely to damage suddenly than traditional concrete structures. Thus, the repair and rehabilitation of SBMC-CBGCSWs damaged by torsional effect have become increasingly necessary. In this paper, an externally-bonded Carbon Fiber-Reinforced Polymers (CFRP) retrofitting technique is presented to repair the damage caused by torsion in SBMC-CBGCSWs, and a test on CFRP-repaired SBMC-CBGCSWs is performed to quantify their torsional response in terms of failure modes, torque-twist curves and strains in the concrete slabs, CFRP and corrugated steel webs. The comparison between CFRP-repaired specimens and the control specimen indicates that CFRP can significantly improve the cracking, yielding and ultimate torques of damaged specimens, as well as the initial torsional rigidity. The experimental results also show that the torsional capacity of CFRP-repaired SBMC-CBGCSWs can be restored to 86-92% of the original specimens, which demonstrates that the externally-bonded CFRP technique is a viable and effective method to repair damaged SBMC-CBGCSWs. Lastly, a simplified method is developed to calculate the torsional capacity of the repaired SBMC-CBGCSWs using CFRP, and the quantification of its effectiveness is presented.
引用
收藏
页数:14
相关论文
共 55 条
[1]  
ACI, 2011, BUILD COD REQ STRUCT
[2]   Torsional strengthening of reinforced concrete beams using different configurations of NSM FRP with epoxy resins and cement-based adhesives [J].
Al-Bayati, G. ;
Al-Mahaidi, R. ;
Kalfat, R. .
COMPOSITE STRUCTURES, 2017, 168 :569-581
[3]   Behavior of FRP strengthened reinforced concrete beams under torsion [J].
Ameli, Mehran ;
Ronagh, Hamid R. ;
Dux, Peter F. .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2007, 11 (02) :192-200
[4]  
Association PCT, 2005, DESIGN CONSTRUCTION
[5]   Influence of reinforcement viscous properties on reliability of existing structures strengthened with externally bonded composites [J].
Berardi, V. P. ;
Feo, L. ;
Mancusi, G. ;
De Piano, M. .
COMPOSITE STRUCTURES, 2018, 200 :532-539
[6]   Torsional Analysis of Multicell Concrete Box Girders Strengthened with CFRP Using a Modified Softened Truss Model [J].
Chai, H. K. ;
Majeed, Abeer A. ;
Allawi, Abbas A. .
JOURNAL OF BRIDGE ENGINEERING, 2015, 20 (08)
[7]   Torsional strengthening of rectangular and flanged beams using carbon fibre-reinforced-polymers - Experimental study [J].
Chalioris, Constantin E. .
CONSTRUCTION AND BUILDING MATERIALS, 2008, 22 (01) :21-29
[8]   Shear capacity of FRP-strengthened RC beams: FRP debonding [J].
Chen, JF ;
Teng, JG .
CONSTRUCTION AND BUILDING MATERIALS, 2003, 17 (01) :27-41
[9]  
Cheyrezy M., 1990, PROC IABSE S MIXED S, P479
[10]   Effectiveness of externally bonded CFRP strips for strengthening flanged beams under torsion: An experimental study [J].
Deifalla, A. ;
Awad, A. ;
Elgarhy, M. .
ENGINEERING STRUCTURES, 2013, 56 :2065-2075