Dental imaging using an ultra-high resolution photon-counting CT system

被引:13
作者
Ruetters, Maurice [1 ]
Sen, Sinan [2 ]
Gehrig, Holger [1 ]
Bruckner, Thomas [3 ]
Kim, Ti-Sun [1 ]
Lux, Christopher J. [4 ]
Schlemmer, Heinz-Peter [5 ]
Heinze, Sarah [6 ]
Maier, Joscha [7 ]
Kachelriess, Marc [7 ,8 ]
Sawall, Stefan [7 ,8 ]
机构
[1] Univ Hosp Heidelberg, Dept Operat Dent, Sect Periodontol, Neuenheimer Feld 400, D-69120 Heidelberg, Germany
[2] Univ Hosp Schleswig Holstein, Dept Orthodont, Arnold Heller Str 3, D-24105 Kiel, Germany
[3] Univ Hosp Heidelberg, Inst Med Biometry, Neuenheimer Feld 130-3, D-69120 Heidelberg, Germany
[4] Univ Hosp Heidelberg, Dept Orthodont, Neuenheimer Feld 400, D-69120 Heidelberg, Germany
[5] German Canc Res Ctr, Neuenheimer Feld 280, D-69120 Heidelberg, Germany
[6] Univ Hosp Heidelberg, Inst Forens & Traff Med, Neuenheimer Feld 400, D-69120 Heidelberg, Germany
[7] German Canc Res Ctr, Div Xray Imaging & CT, Neuenheimer Feld 280, D-69120 Heidelberg, Germany
[8] Heidelberg Univ, Med Fac, Neuenheimer Feld 672, D-69120 Heidelberg, Germany
关键词
COMPUTED-TOMOGRAPHY; VARIABILITY; HEAD; CBCT;
D O I
10.1038/s41598-022-11281-x
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Clinical photon-counting CT (PCCT) offers a spatial resolution of about 200 mu m and might allow for acquisitions close to conventional dental CBCTs. In this study, the capabilities of this new system in comparison to dental CBCTs shall be evaluated. All 8 apical osteolysis identified in CBCT were identified by both readers in all three PCCT scan protocols. Mean visibility scores showed statistical significant differences for root canals(p = 0.0001), periodontal space(p = 0.0090), cortical(p = 0.0003) and spongious bone(p = 0.0293) in favor of high and medium dose PCCT acquisitions. Overall, both devices showed excellent image quality of all structures assessed. Interrater-agreement showed high values for all protocols in all structures. Bland-Altman plots revealed a high concordance of both modalities with the reference measurements. In vitro, ultra-high resolution PCCT can reliably identify different diagnostic entities and structures relevant for dental diagnostics similar to conventional dental CBCT with similar radiation dose. Acquisitions of five cadaveric heads were performed in an experimental CT-system containing an ultra-high resolution PC detector (0.25 mm pixel size in isocenter) as well as in a dental CBCT scanner. Acquisitions were performed using dose levels of 8.5 mGy, 38.0 mGy and 66.5 mGy (CTDI16cm) in case of PCCT and of 8.94 mGy (CTDI16cm) in case of CBCT. The quality of delineation of hard tissues, root-canals, periodontal-space as well as apical osteolysis was assessed by two readers. Mean visibility scores and interrater-agreement (overall agreement (%)) were calculated. Vertical bone loss (bl) and thickness (bt) of the buccal bone lamina of 15 lower incisors were measured and compared to reference measurements by ore microscopy and clinical probing.
引用
收藏
页数:10
相关论文
共 36 条
[1]  
Al Shayeb Kwthar Nassar A, 2014, Prim Dent J, V3, P25
[2]   Two-dimensional Periapical, Panoramic Radiography Versus Three-dimensional Cone-beam Computed Tomography in the Detection of Periapical Lesion After Endodontic Treatment: A Systematic Review [J].
Antony, Delphine P. ;
Thomas, Toby ;
Nivedhitha, M. S. .
CUREUS JOURNAL OF MEDICAL SCIENCE, 2020, 12 (04)
[3]   Radiation doses from head, neck, chest and abdominal CT examinations: an institutional dose report [J].
Atli, Eray ;
Uyanik, Sadik Ahmet ;
Oguslu, Umut ;
Cenkeri, Halime Cevik ;
Yilmaz, Birnur ;
Gumus, Burcak .
DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2021, 27 (01) :147-151
[4]  
Betz W., 2013, AWMF Registernummer, Patent No. [083005, 083005 083005]
[5]  
Bootz F, LEITLINIENPROGRAMM O
[6]   Photon-counting x-ray detectors for CT [J].
Danielsson, Mats ;
Persson, Mats ;
Sjolin, Martin .
PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (03)
[7]  
Floh S., 2016, DTSCH GESELLSCHAFT F
[8]  
Hoefert S, 2017, AWMF Registernummer, Patent No. [007091, 007091 007091]
[9]   The incidence and configuration of the bifid mandibular canal in Koreans by using cone-beam computed tomography [J].
Kang, Ju-Han ;
Lee, Kook-Sun ;
Oh, Min-Gyu ;
Choi, Hwa-Young ;
Lee, Sae-Rom ;
Oh, Song-Hee ;
Choi, Yoon-Joo ;
Kim, Gyu-Tae ;
Choi, Yong-Suk ;
Hwang, Eui-Hwan .
IMAGING SCIENCE IN DENTISTRY, 2014, 44 (01) :53-60
[10]   Assessment and comparison of radiation dose and image quality in multi-detector CT scanners in non-contrast head and neck examinations [J].
Khoramian, Daryoush ;
Sistani, Soroush ;
Firouzjah, Razzagh Abedi .
POLISH JOURNAL OF RADIOLOGY, 2019, 84 :E61-E67