Evaluation of quicklime incorporation in bench-scale and full-scale lime stabilized biosolids using a flat surface pH electrode

被引:2
作者
Burns, Benjamin
Krach, Kenneth
Cole, Charles
Mangus, Jessica
Butler, Howard
Li, Baikun [1 ]
机构
[1] Univ Connecticut, Dept Civil & Environm Engn, Storrs, CT 06269 USA
[2] Penn State Univ Harrisburg, Environm Engn Program, Middletown, PA USA
关键词
D O I
10.1080/1047-3289.57.7.794
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Uniform lime incorporation into sewage sludge is critical for biosolid lime stabilization processes. There is no class B biosolids regulation for lime incorporation. The slurry method is currently used to evaluate the pH of limed biosolids, but this method homogenizes the biosolids and potentially masks poor lime mixing. In this study, a flat-surface pH electrode was used in bench-scale and full-scale experiments to measure the pH of lime-stabilized biosolids without creating slurries. The standard deviation of 15 pH measurements at different locations in a biosolid sample was used to assess mixing quality. The bench-scale experimental study showed that well-mixed limed biosolids had consistently high pHs (similar to 12) with low standard deviations (< 0.5 pH units), whereas poorly mixed biosolids had areas with low pH (< 10) and high standard deviations (> 2 pH units). Poorly mixed biosolids exhibited rapid and marked pH reduction, as well as of fensive odor generation, whereas well-mixed biosolids resisted pH reduction and offensive odor generation. The full-scale study aimed at improving lime incorporation and biosolids quality, confirmed the use of a flat surface pH electrode to capture low pH regions in biosolids that were masked by the current slurry method.
引用
收藏
页码:794 / 802
页数:9
相关论文
共 15 条
[1]   Production of class A biosolids with anoxic low dose alkaline treatment and odor management [J].
Abu-Orf, MM ;
Brewster, J ;
Oleszkiewicz, J ;
Reimers, RS ;
Lagasse, P ;
Amy, B ;
Glindemann, D .
WATER SCIENCE AND TECHNOLOGY, 2004, 49 (10) :131-138
[2]  
Adamchuk VI, 1999, T ASAE, V42, P885, DOI 10.13031/2013.13268
[3]  
*AM PUBL HLTH ASS, 1995, STAND METH EX WAT WA
[4]   ODOR NUISANCES CREATED BY SLUDGE TREATMENT - PROBLEMS AND SOLUTIONS [J].
BONNIN, C ;
LABORIE, A ;
PAILLARD, H .
WATER SCIENCE AND TECHNOLOGY, 1990, 22 (12) :65-74
[5]   USE OF A FLAT-SURFACE COMBINATION PH ELECTRODE FOR MEASUREMENT OF SOIL-PH [J].
BREITENBECK, GA ;
BREMNER, JM .
COMMUNICATIONS IN SOIL SCIENCE AND PLANT ANALYSIS, 1984, 15 (02) :87-98
[6]  
BURNHAM JC, 1992, AM SOC TEST MATER, V1135, P128, DOI 10.1520/STP15536S
[7]  
*ENV REG TECHN, 2003, CONTR PATH VECT ATTR
[8]   Examination of mechanisms for odor compound generation during lime stabilization [J].
Kim, H ;
Murthy, S ;
Peot, C ;
Ramirez, M ;
Strawn, M ;
Park, CH ;
McConnell, LL .
WATER ENVIRONMENT RESEARCH, 2003, 75 (02) :121-125
[9]  
MURTHY S, 2001, WEF RES BIOS MAN C S
[10]  
*NAT LIM ASS, 1999, NLA FACT SHEET US LI