Validation of a method for the determination of boron in ceramic materials by X-ray fluorescence spectrometry

被引:11
|
作者
Sánchez-Ramos, S [1 ]
Bosch-Reig, F [1 ]
Gimeno-Adelantado, JV [1 ]
Yusá-Marco, DJ [1 ]
Doménech-Carbó, A [1 ]
Berja-Pérez, JA [1 ]
机构
[1] Univ Valencia, Fac Chem, Dept Analyt Chem, E-46100 Valencia, Spain
关键词
boron determination; X-ray fluorescence; ceramics; boracic raw materials; ceramic frits;
D O I
10.1016/S0584-8547(00)00267-6
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A method is proposed for boron determination in ceramic materials, boracic raw materials and ceramics frits of different compositions by wavelength dispersive X-ray fluorescence technique. The instrumental conditions were studied and the sample preparation procedures were optimized. The reference method used was the potentiometric titration of mannitol-boric complex acid and the technique was optimized for the determination of B2O3 in each of the materials used. The samples for XRF determination were obtained as pellets and as glass discs. For the pellets different binders were studied, such as mannitol and cellullose for the samples of raw materials, and polyvinylpirrolidone and methyl cellulose (PVP + MC) for the ceramic frits. Samples were obtained in the form of glass discs using lithium tetraborate and a barium-lead glass (BaPbG) as materials to melt, dilute and homogenize the samples, and increase the analytical signal. A series of calibration curves were obtained and the instrumental variables were optimized. The results obtained with the XRF method were compared with the reference method for several unknown samples. The results obtained with both techniques showed relative errors from 0.7 to 3.2% for B2O3 content ranging between 40.8 and 6.3%, respectively. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1669 / 1677
页数:9
相关论文
共 50 条
  • [41] X-ray fluorescence and X-ray transmission microtomography imaging system
    Pereira, Gabriela R.
    Rocha, Henrique S.
    Anjos, Marcelino J.
    Faria, Paulo
    Perez, Carlos A.
    Lopes, Ricardo T.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 581 (1-2): : 128 - 132
  • [42] Determination of X-ray compression efficiency of a thin film X-ray waveguide structure using marker layer fluorescence
    Tiwari, M. K.
    Nayak, M.
    Lodha, G. S.
    Nandedkar, R. V.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2007, 62 (02) : 137 - 144
  • [43] Comparison of reference-free X-ray fluorescence analysis and X-ray reflectometry for thickness determination in the nanometer range
    Kolbe, M
    Beckhoff, B
    Krumrey, M
    Ulm, G
    APPLIED SURFACE SCIENCE, 2005, 252 (01) : 49 - 52
  • [44] Polarization X-Ray Fluorescence Analysis by Milliwatt X-ray Tube
    Kawai, Jun
    Kato, Toshihide
    Imashuku, Susumu
    TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN, 2024, 110 (12): : 981 - 987
  • [45] Determination of selenium in rat brain by synchrotron radiation X-ray fluorescence
    Schulmann-Choron, N
    Chevallier, P
    de Ceaurriz, J
    Souleau, C
    ANALUSIS, 2000, 28 (04) : 316 - 323
  • [46] Determination of the phosphorus content in potato starch using an energy-dispersive X-ray fluorescence method
    Noda, T
    Tsuda, S
    Mori, M
    Takigawa, S
    Matsuura-Endo, C
    Kim, SJ
    Hashimoto, N
    Yamauchi, H
    FOOD CHEMISTRY, 2006, 95 (04) : 632 - 637
  • [47] Compositional characterization of paint sample by neutron and charge particle activation analysis: validation by energy dispersive X-ray fluorescence spectrometry
    Ghosh, M.
    Sarma, M.
    Dagupta, S.
    Datta, J.
    Swain, K. K.
    ANALYTICAL CHEMISTRY LETTERS, 2024, 14 (03) : 382 - 394
  • [48] Validation of x-ray fluorescence measurements of metals in toenail clippings against inductively coupled plasma mass spectrometry in a Nigerian population
    Specht, Aaron J.
    Kponee, Kale
    Nkpaa, Kpobari W.
    Balcom, Prentiss H.
    Weuve, Jennifer
    Nie, Linda H.
    Weisskopf, Marc G.
    PHYSIOLOGICAL MEASUREMENT, 2018, 39 (08)
  • [49] Comparison of X-ray fluorescence and optical fluorescence measured behind scattering layers as a basis for X-ray fluorescence endoscopy
    Beuthan, J
    Haschke, M
    Dressler, C
    Wacker, F
    BIOMEDIZINISCHE TECHNIK, 2005, 50 (03): : 54 - 59
  • [50] X-ray microbeam transmission/fluorescence method for non-destructive characterization of tungsten coated carbon materials
    Tiseanu, Ion
    Mayer, Matej
    Craciunescu, Teddy
    Hakola, Antti
    Koivuranta, Seppo
    Likonen, Jari
    Ruset, Cristian
    Dobrea, Cosmin