The Sit-to-Stand Transition as a Biomarker for Impairment: Comparison of Instrumented 30-Second Chair Stand Test and Daily Life Transitions in Multiple Sclerosis

被引:13
|
作者
Tulipani, Lindsey J. [1 ]
Meyer, Brett [1 ]
Fox, Samantha [1 ]
Solomon, Andrew J. [2 ]
Mcginnis, Ryan S. [1 ]
机构
[1] Univ Vermont, Dept Elect & Biomed Engn, Burlington, VT 05405 USA
[2] Univ Vermont, Dept Neurol Sci, Burlington, VT 05405 USA
关键词
Wearable; accelerometer; sit-to-stand; multiple sclerosis; falls; FALL RISK; MOBILITY IMPAIRMENT; PARKINSONS-DISEASE; BALANCE; PEOPLE; SENSOR; GAIT; VALIDATION; STRENGTH; METRICS;
D O I
10.1109/TNSRE.2022.3169962
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Falls and mobility deficits are common in people with multiple sclerosis (PwMS) across all levels of clinical disability. However, functional mobility observed in supervised settings may not reflect daily life which may impact assessments of fall risk and impairment in the clinic. To investigate this further, we compared the utility of sensor-based performance metrics from sit-stand transitions during daily life and a structured task to inform fall risk and impairment in PwMS. Thirty-seven PwMS instrumented with wearable sensors (thigh and chest) completed supervised 30-second chair stand tests (30CST) and underwent two days of instrumented daily life monitoring. Performance metrics were computed for sit-stand transitions during daily life and 30CSTs. EDSS sub scores and fall history were used to dichotomize participants into groups: pyramidal/no pyramidal impairment, sensory/no sensory impairment and high/low fall risk. The ability of performance metrics to discriminate between groups was assessed using the area under the curve (AUC). The feature that best discriminated between high and low fall risk was a chest acceleration measurement from the supervised instrumented 30CST (AUC = 0.89). Only chest features indicated sensory impairment, however the task was different between supervised and daily life. The metric that best discriminated pyramidal impairment was a chest-derived feature (AUC = 0.89) from supervised 30CSTs. The highest AUC from daily life was observed in faller classification with the average sit-stand time (0.81). While characterizing sit-stand performance during daily life may yield insights into fall risk and may be performed without a clinic visit, there remains value to conducting supervised functional assessments to provide the best classification performance between the investigated impairments in this sample.
引用
收藏
页码:1213 / 1222
页数:10
相关论文
共 24 条
  • [1] Validity of the 30-Second Sit-to-Stand test as a measure of lower extremity function in persons with multiple sclerosis: Preliminary evidence
    Zheng, Peixuan
    Huynh, Trinh L. T.
    Jones, C. Danielle
    Feasel, Corey D.
    Jeng, Brenda
    Motl, Robert W.
    MULTIPLE SCLEROSIS AND RELATED DISORDERS, 2023, 71
  • [2] Portable Ultrasound-Based Device for Detecting Older Adults' Sit-to-Stand Transitions in Unsupervised 30-Second Chair-Stand Tests
    Cobo, Antonio
    Villalba-Mora, Elena
    Hayn, Dieter
    Ferre, Xavier
    Perez-Rodriguez, Rodrigo
    Sanchez-Sanchez, Alberto
    Bernabe-Espiga, Raquel
    Sanchez-Sanchez, Juan-Luis
    Lopez-Diez-Picazo, Andrea
    Moral, Cristian
    Rodriguez-Manas, Leocadio
    SENSORS, 2020, 20 (07)
  • [3] Evaluation of unsupervised 30-second chair stand test performance assessed by wearable sensors to predict fall status in multiple sclerosis
    Tulipani, Lindsey J.
    Meyer, Brett
    Allen, Dakota
    Solomon, Andrew J.
    McGinnis, Ryan S.
    GAIT & POSTURE, 2022, 94 : 19 - 25
  • [4] Modified 30-Second Sit-to-Stand Test: Reliability and Validity in Older Adults Unable to Complete Traditional Sit-to-Stand Testing
    McAllister, Linda S.
    Palombaro, Kerstin M.
    JOURNAL OF GERIATRIC PHYSICAL THERAPY, 2020, 43 (03) : 153 - 158
  • [5] The reliability and validity of the 30-second chair stand test and modified four square step test in persons with multiple sclerosis
    Ozkeskin, Mehmet
    Ozden, Fatih
    Ar, Ege
    Yuceyar, Nur
    PHYSIOTHERAPY THEORY AND PRACTICE, 2023, 39 (10) : 2189 - 2195
  • [6] 30-Second Chair Stand and 5-Times Sit-to-Stand Tests Are Interesting Tools for Assessing Disability and Ability to Ambulate among Patients with Multiple Sclerosis
    Polidori, Andrea
    Malagoli, Mattia
    Giacalone, Rosario
    Brichetto, Giampaolo
    Bragadin, Margherita Monti
    Prada, Valeria
    LIFE-BASEL, 2024, 14 (06):
  • [7] Feasibility and safety of the 30-second sit-to-stand test delivered via telehealth: An observational study
    Bowman, Amy
    Denehy, Linda
    Benjemaa, Aisha
    Crowe, Jess
    Bruns, Emma
    Hall, Travis
    Traill, Anya
    Edbrooke, Lara
    PM&R, 2023, 15 (01) : 31 - 40
  • [8] 30-Second Chair Stand Test Predicts Countermovement Jump Performance in Young Adults
    Alotaibi, Mansour M.
    Almutairi, Marzouq K.
    Singh, Harshvardhan
    Ithurburn, Matthew P.
    Lein, Donald H., Jr.
    SPORTS HEALTH-A MULTIDISCIPLINARY APPROACH, 2023, 15 (03): : 452 - 458
  • [9] Thigh-Derived Inertial Sensor Metrics to Assess the Sit-to-Stand and Stand-to-Sit Transitions in the Timed Up and Go (TUG) Task for Quantifying Mobility Impairment in Multiple Sclerosis
    Witchel, Harry J.
    Oberndorfer, Caecilia
    Needham, Robert
    Healy, Aoife
    Westling, Carina E., I
    Guppy, Joseph H.
    Bush, Jake
    Barth, Jens
    Herberz, Chantal
    Roggen, Daniel
    Eskofier, Bjoern M.
    Rashid, Waciar
    Chockalingam, Nachiappan
    Klucken, Jochen
    FRONTIERS IN NEUROLOGY, 2018, 9
  • [10] Validity and variability of the 5-repetition sit-to-stand test in patients with multiple sclerosis
    Moller, Andreas Buch
    Bibby, Bo Martin
    Skjerbaek, Anders Guldhammer
    Jensen, Ellen
    Sorensen, Henrik
    Stenager, Egon
    Dalgas, Ulrik
    DISABILITY AND REHABILITATION, 2012, 34 (26) : 2251 - 2258