Impact of windward inlet-opening positions on fluctuation characteristics of wind-driven natural cross ventilation in an isolated house using LES

被引:24
作者
Hawendi, Sherzad [1 ,2 ]
Gao, Shian [1 ]
机构
[1] Univ Leicester, Dept Engn, Leicester, Leics, England
[2] Univ Sulaimani, Sulaimani, Kurdistan Regio, Iraq
关键词
CFD; windward inlet-opening positions; cross ventilation; LES; ventilation rate; LARGE-EDDY SIMULATION; AIR-FLOW CHARACTERISTICS; CFD SIMULATION; NUMERICAL-SIMULATION; BUILDINGS IMPACT; LONG BUILDINGS; TUNNEL; ENVIRONMENT; PRESSURE; MODEL;
D O I
10.1080/14733315.2017.1356054
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents a computational fluid dynamics (CFD) simulation of coupled outdoor wind flow and indoor airflow in the investigation on the horizontal positions of openings on the fluctuation of cross ventilation and flow-field inside an isolated family house. Two inlet-opening positions located at the same height are used to investigate the impact of the position of windward inlet openings on the ventilation rate and flow-field inside the building. Due to unsteady flow and high turbulence near the openings, the study employed the large eddy simulation with the dynamic Smagorinsky subgrid-scale model techniques, with the CFD simulations being validated against data from available wind tunnel experiments. The study showed that the rate of ventilation through openings located near the centre of the building is higher and more steady than the flow rate of openings located near the sides of the building.
引用
收藏
页码:93 / 119
页数:27
相关论文
共 45 条
[1]   A numerical study on the effects of exhaust locations on energy consumption and thermal environment in an office room served by displacement ventilation [J].
Ahmed, Ahmed Qasim ;
Gao, Shian ;
Kareem, Ali Khaleel .
ENERGY CONVERSION AND MANAGEMENT, 2016, 117 :74-85
[2]  
[Anonymous], INT J VENT
[3]  
[Anonymous], 2013, FLUENT US GUID
[4]   Wind-induced ventilation performances and airflow characteristics in an areaway-attached basement with a single-sided opening [J].
Bu, Zhen ;
Kato, Shinsuke .
BUILDING AND ENVIRONMENT, 2011, 46 (04) :911-921
[5]  
Cant S., 2000, SB POPE TURBULENT FL, P771
[6]   Index of resolution quality for large eddy simulations [J].
Celik, IB ;
Cehreli, ZN ;
Yavuz, I .
JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2005, 127 (05) :949-958
[7]   Wind-driven cross ventilation in long buildings [J].
Chu, Chia-Ren ;
Chiang, Bo-Fan .
BUILDING AND ENVIRONMENT, 2014, 80 :150-158
[8]   Wind-driven cross ventilation with internal obstacles [J].
Chu, Chia-Ren ;
Chiang, Bo-Fan .
ENERGY AND BUILDINGS, 2013, 67 :201-209
[9]   Numerical study of the cross-ventilation of an isolated building with different opening aspect ratios and locations for various wind directions [J].
Derakhshan, Shahram ;
Shaker, Ahmad .
INTERNATIONAL JOURNAL OF VENTILATION, 2017, 16 (01) :42-60
[10]  
ELMUALIM A.A., 2002, International Journal of Ventilation, V1, P53, DOI 10.1080/14733315.2002.11683622