Vertical spatial sensitivity and exploration depth of low-induction-number electromagnetic-induction instruments

被引:134
作者
Callegary, James B.
Ferre, Ty P. A.
Groom, R. W.
机构
[1] US Geol Survey, Tucson, AZ 85719 USA
[2] Univ Arizona, Tucson, AZ 85721 USA
[3] PetRos EiKon Inc, Concord, ON L4K 2K1, Canada
来源
VADOSE ZONE JOURNAL | 2007年 / 6卷 / 01期
关键词
D O I
10.2136/vzj2006.0120
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Vertical spatial sensitivity and effective depth of exploration ( d(e)) of low-induction-number ( LIN) instruments over a layered soil were evaluated using a complete numerical solution to Maxwell's equations. Previous studies using approximate mathematical solutions predicted a vertical spatial sensitivity for instruments operating under LIN conditions that, for a given transmitter-receiver coil separation (s), coil orientation, and transmitter frequency, should depend solely on depth below the land surface. When not operating under LIN conditions, vertical spatial sensitivity and d(e) also depend on apparent soil electrical conductivity (sigma(a)) and therefore the induction number (beta). In this new evaluation, we determined the range of sigma(a) and beta values for which the LIN conditions hold and how d(e) changes when they do not. Two-layer soil models were simulated with both horizontal ( HCP) and vertical ( VCP) coplanar coil orientations. Soil layers were given electrical conductivity values ranging from 0.1 to 200 mS m(-1). As expected, d(e) decreased as sigma(a) increased. Only the least electrically conductive soil produced the d(e) expected when operating under LIN conditions. For the VCP orientation, this was 1.6s, decreasing to 0.8s in the most electrically conductive soil. For the HCP orientation, d(e) decreased from 0.76s to 0.51s. Differences between this and previous studies are attributed to inadequate representation of skin-depth effect and scattering at interfaces between layers. When using LIN instruments to identify depth to water tables, interfaces between soil layers, and variations in salt or moisture content, it is important to consider the dependence of d(e) on sigma(a).
引用
收藏
页码:158 / 167
页数:10
相关论文
共 30 条
[2]   Response to pumping of wells in sloping fault zone aquifers [J].
António, F ;
Pacheco, L .
JOURNAL OF HYDROLOGY, 2002, 259 (1-4) :116-135
[3]  
BELLUIGI A, 1949, GEOPHYSICS, V14, P501
[4]  
BENJOUDI H, 2002, J HYDROL, V263, P131
[5]  
FRISCHKNECHT FC, 1987, ELECTROMAGNETIC METH, V1, P365
[6]   New theoretical and practical aspects of electromagnetic soundings at low induction numbers [J].
Gómez-Treviño, E ;
Esparza, FJ ;
Méndez-Delgado, S .
GEOPHYSICS, 2002, 67 (05) :1441-1451
[7]  
Kaufman AA., 1983, Frequency and transient soundings
[8]  
Keller G.V., 1966, ELECT METHODS GEOPHY
[9]  
LANZ E, 1998, J ENVIRON ENG GEOPH, V3, P185
[10]   Monitoring for temporal changes in soil salinity using electromagnetic induction techniques [J].
Lesch, SM ;
Herrero, J ;
Rhoades, JD .
SOIL SCIENCE SOCIETY OF AMERICA JOURNAL, 1998, 62 (01) :232-242