Reliability of Chest Wall Mobility and Its Correlation With Pulmonary Function in Patients With Chronic Obstructive Pulmonary Disease

被引:0
作者
Malaguti, Carla [1 ]
Rondelli, Rafaella R.
de Souza, Leandra M. [2 ]
Domingues, Marcia [2 ]
Dal Corso, Simone
机构
[1] Univ Nove de Julho, Rehabil Sci Masters Program, BR-05001100 Sao Paulo, Brazil
[2] Nove de Julho Univ, Dept Hlth, Sch Physiotherapy, BR-05001100 Sao Paulo, Brazil
关键词
chronic obstructive pulmonary disease; COPD; pulmonary function; respiratory mechanics; reliability; EXERCISE; MOTION;
D O I
暂无
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
BACKGROUND: Measurements of chest wall circumference are commonly used by physical therapists in clinical practice in order to determine chest wall mobility. However, the variability in the method for measuring this has not been reported previously among patients with chronic obstructive pulmonary disease. OBJECTIVE: To analyze the reliability and accuracy of chest wall mobility measurements and to investigate the association between chest wall mobility and inspiratory capacity. METHODS: Twenty-six patients with chronic obstructive pulmonary disease (forced expiratory volume in the first second = 45 +/- 14% of predicted) were evaluated over 2 visits. Spirometry was performed during the first visit, to characterize the sample. At each visit, 2 independent observers made chest wall mobility measurements twice, at the levels of the axillary, xiphisternal, and abdominal regions (total of 4 measurements), using a measuring tape. RESULTS: Despite high variability at all levels, the main results were that (1) two measurements made on the same day by the same observer showed good reliability (intraclass correlation coefficient 0.84-0.95); (2) two independent observers making the measurements on the same day showed fair-good reliability (intraclass correlation coefficient 0.69-0.89); (3) the same observer making the measurements at different visits, at least 2 days apart, showed good reliability (intraclass correlation coefficient 0.64-0.84); (4) inspiratory capacity was not associated with axillary and xiphisternal mobility, but it was closely related to measurements taken at the abdominal level. CONCLUSIONS: In summary, despite high reliability of intra-observer and inter-observer measurements, both within and between visits, high variability was observed in all chest wall mobility measurements. Although there was an association between inspiratory capacity and measurements made at the abdominal level, chest wall mobility did not correlate with pulmonary function.
引用
收藏
页码:1703 / 1711
页数:9
相关论文
共 30 条
[1]   Electrophysiologic techniques for the assessment of respiratory muscle function [J].
Aldrich, TK ;
Sinderby, C ;
McKenzie, DK ;
Estenne, M ;
Gandevia, SC .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2002, 166 (04) :548-+
[2]   Regional chest wall volumes during exercise in chronic obstructive pulmonary disease [J].
Aliverti, A ;
Stevenson, N ;
Dellacà, RL ;
Lo Mauro, A ;
Pedotti, A ;
Calverley, PMA .
THORAX, 2004, 59 (03) :210-216
[4]  
[Anonymous], 1992, J Bras Pneumol
[5]   Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine [J].
Atkinson, G ;
Nevill, AM .
SPORTS MEDICINE, 1998, 26 (04) :217-238
[6]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[7]  
Bockenhauer SE, 2007, J AM OSTEOPATH ASSOC, V107, P191
[8]  
Bockenhauer Susan E., 2002, Journal of the American Osteopathic Association, V102, P371
[9]  
BRANCATISANO T, 1984, AM REV RESPIR DIS, V129, P33
[10]  
Caldeira Valéria da Silva, 2007, J. bras. pneumol., V33, P519, DOI 10.1590/S1806-37132007000500006