Continuous fraction collection of gas chromatographic separations with parallel mass spectrometric detection applied to cell-based bioactivity analysis

被引:11
作者
Jonker, Willem [1 ]
Zwart, Nick [2 ]
Stockl, Jan B. [1 ]
de Koning, Sjaak [3 ]
Schaap, Jaap [3 ]
Lamoree, Marja H. [2 ]
Somsen, Govert W. [1 ]
Hamers, Timo [2 ]
Kool, Jeroen [1 ]
机构
[1] Vrije Univ Amsterdam, Div BioAnalyt Chem, De Boelelaan 1108, NL-1081 HZ Amsterdam, Netherlands
[2] Vrije Univ Amsterdam, Dept Environm & Hlth, De Boelelaan 1108, NL-1081 HZ Amsterdam, Netherlands
[3] Da Vinci Lab Solut BV, Cairostr 10, NL-3047 BC Rotterdam, Netherlands
关键词
Gas chromatography; Mass spectrometry; Fractionation; Reporter gene assay; Split ratio; Anti-androgens; POLYCYCLIC AROMATIC-HYDROCARBONS; MAGNETIC-RESONANCE-SPECTROSCOPY; ENVIRONMENTAL CHEMICALS; SYSTEM; RADIOCARBON; COMPOUND; COLUMN; ASSAYS;
D O I
10.1016/j.talanta.2017.02.067
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We describe the development and evaluation of a GC-MS fractionation platform that combines high-resolution fraction collection of full chromatograms with parallel MS detection. A y-split at the column divides the effluent towards the MS detector and towards an inverted y-piece where vaporized trap solvent is infused. The latter flow is directed outside the GC oven allowing subsequent condensation and stepwise collection of liquid fractions with trapped analytes on a 384-well plate. For study and optimization of the effluent split ratio, restriction capillaries of different lengths and diameters were evaluated. For a wide range of settings, local pressures were monitored during fractionation to assess the influence of MS vacuum and trap solvent infusion on the GC system stability. The platform performance was evaluated by GC-MS analysis and continuous fractionation of an n-alkane mixture followed by GC analysis of each fraction. Comparison of the on-line recorded and fraction reconstructed chromatogram showed the GC separation is maintained during fractionation. Multiple fractionation cycles of the n-alkane sample on the same 384-well plate yielded a reconstructed chromatogram which was highly similar to that of a single analysis, demonstrating the high repeatability. The applicability of the GC-MS fractionation platform for bioactivity screening was investigated by applying the AR-Ecoscreen reporter gene bioassay on fractions obtained after analysis of standard solutions and dust samples containing the anti androgenic compounds vinclozolin and p,p'-DDE.
引用
收藏
页码:162 / 167
页数:6
相关论文
共 23 条
[1]   Evaluation of a rapid in vitro androgen receptor transcriptional activation assay using AR-EcoScreen™ cells [J].
Araki, N ;
Ohno, K ;
Takeyoshi, M ;
Iida, M .
TOXICOLOGY IN VITRO, 2005, 19 (03) :335-352
[2]   Gas chromatographic isolation of individual compounds from complex matrices for radiocarbon dating [J].
Eglinton, TI ;
Aluwihare, LI ;
Bauer, JE ;
Druffel, ERM ;
McNichol, AP .
ANALYTICAL CHEMISTRY, 1996, 68 (05) :904-912
[3]   Method for small-molecule discovery based on microscale-preparative multidimensional gas chromatography isolation with nuclear magnetic resonance spectroscopy [J].
Eyres, Graham T. ;
Urban, Sylvia ;
Morrison, Paul D. ;
Dufour, Jean-Pierre ;
Marriott, Philip J. .
ANALYTICAL CHEMISTRY, 2008, 80 (16) :6293-6299
[4]   Chlorine isotope fractionation of a semi-volatile organochlorine compound during preparative megabore-column capillary gas chromatography [J].
Holmstrand, H ;
Mandalakis, M ;
Zencak, Z ;
Gustafsson, Ö ;
Andersson, P .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1103 (01) :133-138
[5]   Gas chromatography fractionation platform featuring parallel flame-ionization detection and continuous high-resolution analyte collection in 384-well plates [J].
Jonker, Willem ;
Clarijs, Bas ;
de Witte, Susannah L. ;
van Velzen, Martin ;
de Koning, Sjaak ;
Schaap, Jaap ;
Somsen, Govert W. ;
Kool, Jeroen .
JOURNAL OF CHROMATOGRAPHY A, 2016, 1462 :100-106
[6]  
Körner W, 2004, ENVIRON HEALTH PERSP, V112, P695, DOI [10.1289/ehp.6715, 10.1289/ehp.112-1241964]
[7]   Contribution of biomass burning to atmospheric polycyclic aromatic hydrocarbons at three European background sites [J].
Mandalakis, M ;
Gustafsson, Ö ;
Alsberg, T ;
Egebäck, AL ;
Reddy, CM ;
Xu, L ;
Klanova, J ;
Holoubek, I ;
Stephanou, EG .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2005, 39 (09) :2976-2982
[8]   Optimization of a preparative capillary gas chromatography-mass spectrometry system for the isolation and harvesting of individual polycyclic aromatic hydrocarbons [J].
Mandalakis, M ;
Gustafsson, Ö .
JOURNAL OF CHROMATOGRAPHY A, 2003, 996 (1-2) :163-172
[9]   Fractionation of technical p-nonylphenol with preparative capillary gas chromatography [J].
Meinert, Cornelia ;
Moeder, Monika ;
Brack, Werner .
CHEMOSPHERE, 2007, 70 (02) :215-223
[10]   Application of preparative capillary gas chromatography (pcGC), automated structure generation and mutagenicity prediction to improve effect-directed analysis of genotoxicants in a contaminated groundwater [J].
Meinert, Cornelia ;
Schymanski, Emma ;
Kuester, Eberhard ;
Kuehne, Ralph ;
Schueuermann, Gerrit ;
Brack, Werner .
ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2010, 17 (04) :885-897