Analysis of Fractional Order Sliding Mode Control in a D-STATCOM Integrated Power Distribution System

被引:34
作者
Ahmed, Toqeer [1 ,2 ]
Waqar, Asad [1 ]
Elavarasan, Rajvikram Madurai [3 ]
Imtiaz, Junaid [1 ]
Premkumar, Manoharan [4 ]
Subramaniam, Umashankar [5 ]
机构
[1] Bahria Univ, Dept Elect Engn, Islamabad 44000, Pakistan
[2] Int Islamic Univ, Ctr Adv Elect & Photovolta Engn CAEPE, Islamabad 44000, Pakistan
[3] Texas A&M Univ, Clean & Resilient Energy Syst CARES Lab, Galveston, TX 77553 USA
[4] Dayananda Sagar Coll Engn, Dept Elect & Elect Engn, Bengaluru 560078, India
[5] Prince Sultan Univ, Dept Commun & Networks, Renewable Energy Lab, Riyadh 11586, Saudi Arabia
关键词
Automatic voltage control; Power quality; Reactive power; Voltage fluctuations; Power distribution; Harmonic analysis; Stability analysis; custom power devices; distribution static compensator; fractional order sliding mode control; total harmonic distortion; voltage unbalance factor; REAL-TIME IMPLEMENTATION; QUALITY IMPROVEMENT; DSTATCOM; DESIGN; COMPENSATOR; MITIGATION; STABILITY; NETWORK;
D O I
10.1109/ACCESS.2021.3078608
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
At present, the disturbances like the voltage fluctuations, resulting from the grid's complexities and unbalanced load conditions, create severe power quality concerns like total harmonic distortion (THD) and voltage unbalance factor (VUF) of the grid voltage. Though the custom power devices such as distribution-static compensators (D-STATCOMs) improve these power quality concerns, however, the accompanying controller plays the substantial role. Therefore, this paper proposes a fractional-order sliding mode control (FOSMC) for a D-STATCOM to compensate the low power distribution system by injecting/absorbing a specific extent of the reactive power under disturbances. FOSMC is a non-linear robust control in which the sliding surface is designed by using the Riemann-Liouville (RL) function and the chattering phenomenon is minimized by using the exponential reaching law. The stability of FOSMC is evidenced by employing the Lyapunov stability criteria. Moreover, the performance of the proposed FOSMC is further accessed while doing its parametric variations. The complete system is demonstrated with a model of 400V, 180kVA radial distributor along with D-STATCOM under two test scenarios in MATLAB/Simulink environment. The results of the proposed controller are compared with the fixed frequency sliding mode control (FFSMC) and conventional proportional-integral (PI) control. The results validate the superiority of the proposed controller in terms of rapid tracking, fast convergence, and overall damping with very low THD and VUF.
引用
收藏
页码:70337 / 70352
页数:16
相关论文
共 87 条
[1]  
Abdalaal RM, 2020, APPL POWER ELECT CO, P989, DOI [10.1109/APEC39645.2020.9124219, 10.1109/apec39645.2020.9124219]
[2]   Energy Management of a Battery Storage and D-STATCOM Integrated Power System Using the Fractional Order Sliding Mode Control [J].
Ahmed, Toqeer ;
Waqar, Asad ;
Al-Ammar, Essam A. ;
Ko, Wonsuk ;
Kim, Yongki ;
Aamir, Muhammad ;
Habib, Habib Ur Rahman .
CSEE JOURNAL OF POWER AND ENERGY SYSTEMS, 2021, 7 (05) :996-1010
[3]   Power Quality Assessment of Grid-Connected PV System in Compliance with the Recent Integration Requirements [J].
Al-Shetwi, Ali Q. ;
Hannan, M. A. ;
Jern, Ker Pin ;
Alkahtani, Ammar A. ;
Abas, A. E. P. G. .
ELECTRONICS, 2020, 9 (02)
[4]   A Survey on Power System Blackout and Cascading Events: Research Motivations and Challenges [J].
Alhelou, Hassan Haes ;
Hamedani-Golshan, Mohamad Esmail ;
Njenda, Takawira Cuthbert ;
Siano, Pierluigi .
ENERGIES, 2019, 12 (04)
[5]   Power Quality in Microgrids Including Supraharmonics: Issues, Standards, and Mitigations [J].
Alkahtani, Ammar Ahmed ;
Alfalahi, Saad T. Y. ;
Athamneh, Abedalgany Abedallah ;
Al-Shetwi, Ali Q. ;
Bin Mansor, Muhamad ;
Hannan, M. A. ;
Agelidis, Vassilios G. .
IEEE ACCESS, 2020, 8 (08) :127104-127122
[6]   DSTATCOM modelling for voltage stability with fuzzy logic PI current controller [J].
Amoozegar, Dawood .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2016, 76 :129-135
[7]  
[Anonymous], 2019, IEEE Std 1159-2019 (Revision of IEEE Std 1159-2009), DOI [DOI 10.1109/IEEESTD.2019.8796486, 10.1109/IEEESTD.2019.8859685, DOI 10.1109/IEEESTD.2009.5154067]
[8]   Real-time implementation of active shunt compensator with adaptive SRLMMN control technique for power quality improvement in the distribution system [J].
Badoni, Manoj ;
Singh, Alka ;
Singh, Bhim ;
Saxena, Hemant .
IET GENERATION TRANSMISSION & DISTRIBUTION, 2020, 14 (08) :1598-1606
[9]   Enhancing Power Quality in Microgrids With a New Online Control Strategy for DSTATCOM Using Reinforcement Learning Algorithm [J].
Bagheri, Mehdi ;
Nurmanova, Venera ;
Abedinia, Oveis ;
Naderi, Mohammad Salay .
IEEE ACCESS, 2018, 6 :38986-38996
[10]   Allocation of Static Var Compensator in Electric Power Systems Considering Different Load Levels [J].
Belati, Edmarcio A. ;
Nascimento, Claudionor F. ;
de Faria, Haroldo, Jr. ;
Watanabe, Edson H. ;
Padilha-Feltrin, Antonio .
JOURNAL OF CONTROL AUTOMATION AND ELECTRICAL SYSTEMS, 2019, 30 (01) :1-8